DOWNLOAD Sony HDR-HC1 / HDR-HC1E / HDR-HC1EK / HDR-HC1K (serv.man4) Service Manual ↓ Size: 1005.39 KB | Pages: 91 in PDF or view online for FREE

Model
HDR-HC1 HDR-HC1E HDR-HC1EK HDR-HC1K (serv.man4)
Pages
91
Size
1005.39 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc1-hdr-hc1e-hdr-hc1ek-hdr-hc1k-sm4.pdf
Date

Sony HDR-HC1 / HDR-HC1E / HDR-HC1EK / HDR-HC1K (serv.man4) Service Manual ▷ View online

6-39
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
13. LV Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the normal coefficient of the light value at 3200K.
Subject
Clear chart (All white frame)
Measurement Point
Displayed data of page: 1 (Note 4)
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
2A, 2B
Specified Value
0FE0 to 1020
Note 1: Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Note 4: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”
2
0
01
01
3
6
4D
40
4
6
C9
10
5
Wait for 6 seconds.
6
6
01
0D
Press PAUSE button. (Note 5)
7
6
02
Check the data changes to
“01”.
8
0
03
1E
9
1
Check that the displayed data
(Note 4) satisfied the
specified value.
Note 5: The adjustment data will be automatically input to page:
6F, address: 2A, 2B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
4D
00
2
6
C9
00
3
6
01
00
Press PAUSE button.
4
0
03
00
5
0
01
00
6-40
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
14. Auto White Balance Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart (All white frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
6E
6F
Adjustment Address
10 to 1F
FC to FF
Note 1: Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2: If reading/writing data on pages 6E, 6F, set data: 06 to
page: 0, address: 10, and then select pages: E, F. By this
data setting, the pages 6E, 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”
2
Place the C14 filter on the
lens.
3
0
01
01
4
6
4D
40
5
Wait for 2 seconds.
6
0
10
06
7
F
FC
2C
Press PAUSE button.
(6F)
8
F
FD
C0
Press PAUSE button.
(6F)
9
F
FE
59
Press PAUSE button.
(6F)
10
F
FF
00
Press PAUSE button.
(6F)
11
0
10
00
12
6
01
47
Press PAUSE button.
13
6
01
45
Press PAUSE button. (Note 4)
14
6
02
Check the data changes to
“01”.
Note 4: The adjustment data will be automatically input to page:
6E, address: 10 to 1F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
4D
00
2
6
01
00
Press PAUSE button.
3
0
01
00
4
Remove the C14 filter on the
lens.
6-41
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
15. Picture Frame Setting
(Color reproduction adjustment frame)
Subject
Color bar chart
(Color reproduction adjustment
frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope and monitor TV (16:9)
Specified Value
A=B, C=D, E=F
Note 1: Perform “Hall Adjustment” and “Flange Back Adjust-
ment” before this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu Setting) ......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Setting method:
Order Page Address Data
Procedure
1
6
4D
40
2
Adjust the zoom and the
camera direction, and set the
specified position.
3
Mark the position of the
picture frame on the monitor
TV, and adjust the picture
frame to this position in
following adjustment using
“Color reproduction
adjustment frame”.
How to read the XH, XL, YH and YL data:
Order Page Address Data
Procedure
1
0
03
18
2
1
Read XH data and XL data.
(Note 3)
3
0
03
22
4
1
Read YH data and YL data.
(Note 3)
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-11
2. Vertical period
Fig. 6-1-12
Check on the monitor TV (Underscanned mode)
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
4D
40
2
6
90
XL
3
6
91
XH
4
6
92
YL
5
6
93
YH
6
6
01
79
Press PAUSE button.
How to release the picture frame setting:
Order Page Address Data
Procedure
1
6
4D
00
2
6
01
00
Press PAUSE button.
3
6
90
00
4
6
91
00
5
6
92
00
6
6
93
00
Fig. 6-1-13
H
A = B
C = D
A B
C D
E = F = 0
V
E
F
Color bar chart picture frame
Monitor TV picture frame
A = B
E = F = 0
C = D
A
B
E
F
C
D
6-42
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
16. Color Reproduction Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment
frame)
Adjustment Page
6E
Adjustment Address
20 to 3F
Note 1: If reading/writing data on pages 6E, set data: 06 to page:
0, address: 10, and then select pages: E. By this data
setting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting). ......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Color Reproduction
Adjustment Frame”. If not,
perform“15. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”
2
0
01
01
3
6
4D
40
4
6
1F
10
5
6
15
92
 6
6
14
84
(NTSC model only)
7
6
C9
10
8
6
9E
00
9
6
9D
37
10
6
01
61
Press PAUSE button. (Note 3)
11
6
02
Check the data changes to
“01”.
Note 3: The adjustment data will be automatically input to page:
6E, address: 20 to 3F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
14
00
(NTSC model only)
3
6
15
00
4
6
1F
00
5
6
4D
00
6
6
9D
00
7
6
C9
00
8
0
01
00
Page of 91
Display

Click on the first or last page to see other HDR-HC1 / HDR-HC1E / HDR-HC1EK / HDR-HC1K (serv.man4) service manuals if exist.