6-2.
Flange Back Adjustment (2) 
RadarW
RadarW
RadarW
RadarW
RadarW
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
48 to 58
Specified value
Data of page: 6F, address: 57 is“00” to “09”
Data of page: 6, address: 0C is“00”
Note 1: Perform the adjustment with the lens in horizontal state.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Note 4: Don't touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
4) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
4D
40
3
6
64
04
4
6
01
13
Press PAUSE button.
5
Wait for 2 seconds.
6
Place ND filter on the lens so
that the optimum image is
obtain.
7
6
01
29
Press PAUSE button. (Note 5)
8
6
02
Check the data changes to “01”.
9
6
0C
Check the data is “00”.
10
0
10
06
11
F
57
Check the data is “00” to “09”.
(6F)
12
0
10
00
Note 5: The adjustment data will be automatically input to page:
6F, address: 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
6
4D
00
5
6
64
00
6
0
01
00
7
Perform “Flange Back
Check”.
6-36
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
8.
Flange Back Check (Using the Siemens star)
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Note 2: When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Preparations before adjustments:
1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
6
4D
40
4
6
64
04
5
Shoot the Siemens star with
the zoom TELE end.
6
Turn on the auto focus.
7
0
03
0F
8
1
Check that the lens is
focused. (Note 2)
9
6
21
10
10
Shoot the Siemens star with
the zoom WIDE end.
11
Observe the TV monitor and
check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
6
4D
40
5
6
64
04
6
0
03
00
7.
Flange Back Check
(Using the flange back adjustment jig)
Subject
Flange back adjustment jig
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) To open the IRIS, decrease the luminous intensity to the chart
of the flange back adjustment jig up to a point before noise
appear on the image. (approx. 200 lux)
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
6
4D
40
4
6
64
04
5
Shoot the chart with the
zoom TELE end.
6
6
2C
02
7
Check that the lens is
focused.
8
Shoot the chart with the
zoom WIDE end.
9
Check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
6
40
00
3
6
41
00
4
6
4D
00
5
6
64
00
6-37
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
10. Mechanical Shutter Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the close time and loss time every F number of the me-
chanical shutter and the high-speed shutter correction value to
correct the luminous exposure.
Adjustment Page
6F
Adjustment Address
76 to 8B
Note 1: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: 6F, address: 76 to 8B.
Note 2: Press the PAUSE button of the adjustment remote com-
mander each time to set data.
Address
Data
NTSC PAL
76
96
7D
77
00
00
78
68
56
79
00
00
7A
50
43
7B
00
00
7C
40
35
7D
00
00
7E
33
2A
7F
00
83
80
54
53
81
5F
60
82
5D
5D
83
55
55
84
4A
49
85
20
20
86
80
80
87
80
80
88
80
80
89
80
80
8A
80
80
8B
80
80
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
9.
F No. & ND Light Quality Standard Data Input
RadarW
RadarW
RadarW
RadarW
RadarW
Correct the lens iris and dispersion of the ND filter light quantity.
Adjustment Page
6F
Adjustment Address
1C to 29
Note 1: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: 6F, address: 1C to 29.
Note 2: Press the PAUSE button of the adjustment remote com-
mander each time to set data.
Address
Data
NTSC PAL
1C
00
00
1D
00
00
1E
00
00
1F
00
00
20
00
00
21
00
00
22
00
00
23
00
00
24
00
00
25
00
00
26
00
00
27
00
00
28
00
00
29
00
00
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
6-38
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
12. Auto White Balance Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart (All white frame)
Adjustment Page
6E
Adjustment Address
00 to 0F
Note 1: Perform “F No. & ND Light Quality Standard Data In-
put” before this adjustment.
Note 2: If reading/writing data on pages 6E, set data: 06 to page:
0, address: 10, and then select pages: E. By this data
setting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”
2
0
01
01
3
6
4D
40
4
Wait for 2 seconds.
5
6
01
43
Press PAUSE button.
6
6
01
41
Press PAUSE button. (Note 4)
7
6
02
Check the data changes to
“01”.
Note 4: The adjustment data will be automatically input to page:
6E, address: 00 to 0F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
4D
00
2
6
01
00
Press PAUSE button.
3
0
01
00
11. Picture Frame Setting (All white frame)
Subject
Clear chart (All white frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V jack (75 
terminated)
Measuring Instrument
Monitor TV
Specified Value
Only the clear chart must be shot
(entire screen is white).
Note: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS ................................................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Setting method:
Order Page Address Data
Procedure
1
Shoot a clear chart in the
center of screen with the
zoom at WIDE end.
2
6
90
70
3
6
91
02
4
6
92
00
5
6
93
46
6
6
01
79
Press PAUSE button.
7
Check that the entire screen
is white.
8
In the following adjustment,
if the “All white frame” is
used, adjust the clear chart to
this position.
Processing after Completing Adjustment:
Reset the data setting after the adjustment finished.
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00