Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc1-hdr-hc1e-hdr-hc1ek-hdr-hc1k-sm4.pdf
Date

Sony HDR-HC1 / HDR-HC1E / HDR-HC1EK / HDR-HC1K (serv.man4) Service Manual ▷ View online

6-31
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
4.
Image Sensor Output 2ch Matching Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Correct the dispersion of between the left-right channels of CMOS
imager.
Subject
Clear chart (All white) (Note 1)
Adjustment Page
6F
Adjustment Address
B8 to F6
Note 1: Shoot the clear chart with the zoom TELE end.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: 6. By this data
setting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) ZOOM ..................................................................... TELE end
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
2C
01
3
6
40
01
4
6
D0
60
5
6
D6
02
6
6
01
F5
Press PAUSE button. (Note 4)
7
6
02
Check the data changes to
“01”.
Note 4: The adjustment data will be automatically input to page:
6F, address: B8 to F6.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
40
00
4
6
D0
00
5
6
D6
00
6
0
01
00
6-32
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
5.
Flange Back and Zoom Lever Center Adjustment
RadarW
RadarW
RadarW
 (Using the minipattern box or flange
back adjustment jig)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
minipattern box (Note 1) or flange
back adjustment jig
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
11, 48 to 58
Specified value
Data of page: 6F, address: 57 is
“00” to “09”
Data of pege: 6, address: 0C is “00”
Note 1: Dark Siemens star chart.
Note 2: Perform “HALL Adjustment”, “MR Adjustment” and
“Image Sensor Output 2ch Matching Adjustment” be-
fore this adjustment.
Note 3: Perform the adjustment with the lens in horizontal state.
Note 4: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 5: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Note 6: Don't touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
4) REC FORMAT (Menu setting) ............................. HDV1080i
Preparation (Using the minipattern box)
1) The minipattern box is installed as shown in the following fig-
ure.
Note 7: The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Fig. 6-1-9
Preparation (Using the flange back adjustment jig)
(Luminance: 300 to 400 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-10
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
± 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
6-33
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
4D
40
3
6
64
04
4
0
10
06
5
B
0D
Set the bit value of bit3 is
(6B)
“1”, and press PAUSE
button. (Note 8)
6
0
10
00
7
6
01
13
Press PAUSE button.
8
Wait for 2 seconds.
9
6
01
27
Press PAUSE button. (Note 9)
10
6
02
Check the data changes to “01”.
11
6
0C
Check the data is “00”.
12
0
10
06
F
13
(6F)
57
Check the data is “00” to “09”.
14
0
10
00
Note 8: For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
Note 9: The adjustment data will be automatically input to page:
6F, address: 11, 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
6
4D
00
5
6
64
00
6
0
10
06
B
Set the bit value of bit3 is
7
(6B)
0D
“0”, and press PAUSE
button. (Note 8)
8
0
10
00
9
0
01
00
10
Perform “Flange Back
Check”.
6-34
HDR-HC1/HC1E/HC1K/HC1EK_ADJ
6.
Flange Back and Zoom Lever Center Adjustment
(Using the flange back adjustment chart and
subject more than 500 m away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
6-1.
Flange Back Adjustment (1) 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
11, 48 to 58
Specified value
Data of page: 6F, address: 57 is
“00” to “09”
Data of pege: 6, address: 0C is “00”
Note 1: Perform “HALL Adjustment”, “MR Adjustment” and
“Image Sensor Output 2ch Matching Adjustment” be-
fore this adjustment.
Note 2: Perform the adjustment with the lens in horizontal state.
Note 3: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 4: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Note 5: Don't touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
4) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
4D
40
3
6
64
04
4
0
10
06
5
B
0D
Set the bit value of bit3 is
(6B)
“1”, and press PAUSE
button. (Note 6)
6
0
10
00
7
6
01
13
Press PAUSE button.
8
Wait for 2 seconds.
9
6
01
15
Press PAUSE button. (Note 7)
10
6
02
Check the data changes to
“01”.
11
6
0C
Check the data is “00”.
12
0
10
06
13
F
57
Check the data is “00” to
(6F)
“09”.
14
0
10
00
Note 6: For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
Note 7: The adjustment data will be automatically input to page:
6F, address: 11, 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
6
4D
00
5
6
64
00
6
0
10
06
7
B
0D
Set the bit value of bit3 is
(6B)
“0”, and press PAUSE
button. (Note 6)
8
0
10
00
9
0
01
00
10
Perform “Flange Back
Adjustment (2)”.
Page of 91