DOWNLOAD Sony DCR-VX2200E (serv.man2) Service Manual ↓ Size: 847.27 KB | Pages: 80 in PDF or view online for FREE

Model
DCR-VX2200E (serv.man2)
Pages
80
Size
847.27 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-vx2200e-sm2.pdf
Date

Sony DCR-VX2200E (serv.man2) Service Manual ▷ View online

6-44
DCR-VX2200E_ADJ
30. White Defect Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Detect white defective pixels (FD white point) of CMOS image
sensor.
Subject
Not required
Note 1:
Perform “White Defect & HS Defect Adjustment” be-
fore this adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
D0
0C
5
6
01
21
Press PAUSE (Write) button.
6
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
31. White Defect Check 
RadarW
RadarW
RadarW
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value 1
Data of page: 6 address: D1 is “00”
Specified value 2
Data of page: 6, address: D2 is “00”
to “06”
Note 1:
Perform “White Defect Adjustment” before this adjust-
ment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
D0
04
5
6
01
21
Press PAUSE (Write) button.
6
6
02
Check the data changes to
“01”.
7
6
D1
Check the data is “00”.
8
6
D2
Check the data is “00” to
“06”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
6-45
DCR-VX2200E_ADJ
32. Black Defect Adjustment 1 (Bch) 
RadarW
RadarW
RadarW
RadarW
RadarW
Detect black defective pixels of CMOS image sensor.
Subject
Clear chart (All white) (Note 1)
Note 1:
Shoot the clear chart with the zoom TELE end.
Note 2:
 Perform “White Defect Check” before this adjustment.
Note 3:
 Check that the data of page: 0, address: 10 is “00”.
Note 4:
 Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) ZOOM switch (Lens block) ....................................... SERVO
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
99
Check the data is “00”.
5
6
2C
01
6
6
90
00
7
6
91
04
8
6
92
00
9
6
93
10
10
6
01
79
Press PAUSE (Write) button.
11
Wait for 4 seconds.
12
6
01
00
Press PAUSE (Write) button.
13
Check that the entire screen
is white.
14
6
D0
01
15
6
D1
01
16
6
01
21
Press PAUSE (Write) button.
17
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
01
79
Press PAUSE (Write) button.
7
Wait for 4 seconds.
8
6
01
00
Press PAUSE (Write) button.
9
6
2C
00
10
0
01
00
33. Black Defect Adjustment 2 (Gch) 
RadarW
RadarW
RadarW
RadarW
RadarW
Detect black defective pixels of CMOS image sensor.
Subject
Clear chart (All white) (Note 1)
Note 1:
Shoot the clear chart with the zoom TELE end.
Note 2:
 Perform “White Defect Check” before this adjustment.
Note 3:
 Check that the data of page: 0, address: 10 is “00”.
Note 4:
 Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) ZOOM switch (Lens block) ....................................... SERVO
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
99
Check the data is “00”.
5
6
2C
01
6
6
90
00
7
6
91
04
8
6
92
00
9
6
93
10
10
6
01
79
Press PAUSE (Write) button
11
Wait for 4 seconds.
12
6
01
00
Press PAUSE (Write) button.
13
Check that the entire screen
is white.
14
6
D0
01
15
6
D1
02
16
6
01
21
Press PAUSE (Write) button.
17
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
01
79
Press PAUSE (Write) button.
7
Wait for 4 seconds.
8
6
01
00
Press PAUSE (Write) button.
9
6
2C
00
10
0
01
00
6-46
DCR-VX2200E_ADJ
34. Black Defect Adjustment 3 (Rch) 
RadarW
RadarW
RadarW
RadarW
RadarW
Detect black defective pixels of CMOS image sensor.
Subject
Clear chart (All white) (Note 1)
Note 1:
Shoot the clear chart with the zoom TELE end.
Note 2:
 Perform “White Defect Check” before this adjustment.
Note 3:
 Check that the data of page: 0, address: 10 is “00”.
Note 4:
 Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) ZOOM switch (Lens block) ....................................... SERVO
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
3
6
07
Check the data is “04”.
4
6
99
Check the data is “00”.
5
6
2C
01
6
6
90
00
7
6
91
04
8
6
92
00
9
6
93
10
10
6
01
79
Press PAUSE (Write) button.
11
Wait for 4 seconds.
12
6
01
00
Press PAUSE (Write) button.
13
Check that the entire screen
is white.
14
6
D0
01
15
6
D1
04
16
6
01
21
Press PAUSE (Write) button.
17
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
01
79
Press PAUSE (Write) button.
7
Wait for 4 seconds.
8
6
01
00
Press PAUSE (Write) button.
9
6
2C
00
10
0
01
00
35. Angular Velocity Sensor Sensitivity Adjustment
• Perform the angular velocity sensor sensitivity adjustment only
when replacing the angular velocity sensor or lens block. When
the microprocessor, circuit, etc. malfunctions, do not perform
this adjustment but check operations only.
• Record the sensitivity label of the angular velocity sensor (re-
pair part), including to which side of the board it was attached
to, etc. If it has been attached incorrectly, the image will move
up and down or to the left and right during steady shot opera-
tion. Be sure to take note of this.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03RC – 04
Type B
ENC03RD
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing,
readjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
35-1. Angular Velocity Sensor Sensitivity Adjustment (1)
Adjustment Page
7F (Note 1)
Adjustment Address
20
Note 1:
If reading/writing data on pages 7F, set data: 07 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 7F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
The PITCH sensor (SE8501 of GY-014 board) sensitiv-
ity is labeled only the repair parts.
Preparation
1) Read the PITCH sensor (SE8501 of GY-014 board) sensitivity
written on repair parts, and named this as S
20
.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
07
3
Calculate D
20
’ using
following equations.
(decimal calculation)
(Note 3)
D
20
’ = 129 
× (60/S
20
)
4
Convert D
20
’ to a hexadeci-
mal number, and obtain D
20
.
(Note 4)
5
F
20
D
20
Press PAUSE (Write) button.
(7F)
6
0
10
00
Note 3:
S
20
 is read in “Preparation”.
Note 4:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
01
00
2
Check that the steady shot
function operates normally.
6-47
DCR-VX2200E_ADJ
35-2. Angular Velocity Sensor Sensitivity Adjustment (2)
Adjustment Page
7F (Note 1)
Adjustment Address
21
Note 1:
If reading/writing data on pages 7F, set data: 07 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 7F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
The YAW sensor (SE8502 of GY-014 board) sensitivity
is labeled only the repair parts.
Preparation
1) Read the YAW sensor (SE8502 of GY-014 board) sensitivity
written on repair parts, and named this as S
21
.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
07
3
Calculate D
21
’ using
following equations.
(decimal calculation)
(Note 3)
D
21
’ = 128 
× (60/S
21
)
4
Convert D
21
’ to a hexadeci-
mal number, and obtain D
21
.
(Note 4)
5
F
21
D
21
Press PAUSE (Write) button.
(7F)
6
0
10
00
Note 3:
S
21
 is read in “Preparation”.
Note 4:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
01
00
2
Check that the steady shot
function operates normally.
36. Set to Normal Mode
Note:
After perform the camera adjustments, be sure to set to
normal mode.
Perform the following data setting.
Order Page Address Data
Procedure
1
9F
26
Bit:0 
b0
2
07
83
00
3
07
01
D1
4
07
04
00
5
07
02
FF
6
07
00
01
Press PAUSE (Write) button.
7
07
02
Check the data is “01”.
8
07
01
BD
9
07
04
01
10
07
02
FF
11
07
00
01
Press PAUSE (Write) button.
12
07
02
Check the data is “01”.
13
0A
10
00
Press PAUSE (Write) button.
14
00
01
00
15
Reset the hardware.
Page of 80
Display