Sony DCR-VX2200E (serv.man2) Service Manual ▷ View online
6-60
DCR-VX2200E_ADJ
1-2. S VIDEO OUT Y Level Adjustment (VC-597 board)
Mode
VCR mode
Signal
No signal
Measurement Point
Y signal terminal of S VIDEO plug
of A/V Remote connector (75
of A/V Remote connector (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
7E
Specified value
A = 1000
± 14 mVp-p
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
7E
Change the data and set the Y
signal level (A) to the
specified value.
signal level (A) to the
specified value.
3
C
7E
Press PAUSE (Write) button.
4
C
25
Set a value obtained by
adding 3 to the
fore mentioned data, and
press PAUSE (Write) button.
adding 3 to the
fore mentioned data, and
press PAUSE (Write) button.
5
Perform “Processing after
Complete Adjustment”.
Complete Adjustment”.
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the speci-
fied values of “Origin Oscillation Check” of “1-3. CAMERA SYS-
TEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
fied values of “Origin Oscillation Check” of “1-3. CAMERA SYS-
TEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. S VIDEO OUT Y level adjustment
2. S VIDEO OUT chroma level adjustment
3. VIDEO OUT level check
4. COMPONENT OUT Y level adjustment
5. COMPONENT OUT Pr level adjustment
6. COMPONENT OUT Pb level adjustment
1. S VIDEO OUT Y level adjustment
2. S VIDEO OUT chroma level adjustment
3. VIDEO OUT level check
4. COMPONENT OUT Y level adjustment
5. COMPONENT OUT Pr level adjustment
6. COMPONENT OUT Pb level adjustment
3-4-1. S VIDEO, VIDEO OUT Adjustment
1-1. Preparations
1-1. Preparations
Perform the following data setting before the “S VIDEO,
VIDEO OUT Adjustment”.
VIDEO OUT Adjustment”.
Order Page Address Data
Procedure
1
Set the unit to VCR mode.
2
0
01
01
3
7
83
03
4
3
71
01
Press PAUSE (Write) button.
5
0
10
01
6
C
0F
10
Press PAUSE (Write) button.
(1C)
7
8
00
01
Press PAUSE (Write) button.
(18)
8
8
01
60
Press PAUSE (Write) button.
(18)
9
8
06
55
Press PAUSE (Write) button.
(18)
10
8
04
C0
Press PAUSE (Write) button.
(18)
11
Wait for 3.5 seconds.
12
0
10
00
13
0
FF
3E
14
B
00
02
15
C
85
Check the data is “55”.
16
0
FF
00
Fig. 6-3-3
H
A
6-61
DCR-VX2200E_ADJ
1-3. S VIDEO OUT Chroma Level Adjustment
(VC-597 board)
Mode
VCR mode
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
plug of A/V Remote connector (75
Ω terminated)
External trigger: Y signal terminal of
S VIDEO plug of A/V Remote
connector (75
plug of A/V Remote connector (75
Ω terminated)
External trigger: Y signal terminal of
S VIDEO plug of A/V Remote
connector (75
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
7F, 80
Specified value
Cr level: A = 700
± 14 mVp-p
Cb level: B = 700
± 14 mVp-p
Burst level: C = 300
± 6 mVp-p
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
26
Change the data and set the
Cr signal level (A) to the
specified value.
Cr signal level (A) to the
specified value.
3
C
26
Press PAUSE (Write) button.
4
C
7F
Set a value obtained by
subtracting 5 from the
fore mentioned data, and
press PAUSE (Write) button.
subtracting 5 from the
fore mentioned data, and
press PAUSE (Write) button.
5
C
27
Change the data and set the
Cb signal level (B) to the
specified value.
Cb signal level (B) to the
specified value.
6
C
27
Press PAUSE (Write) button.
7
C
80
Set a value obtained by
subtracting 3 from the
fore mentioned data, and
press PAUSE (Write) button.
subtracting 3 from the
fore mentioned data, and
press PAUSE (Write) button.
8
Check the burst signal (C) to
the specified value.
the specified value.
9
Perform “Processing after
Complete Adjustment”.
Complete Adjustment”.
Fig. 6-3-4
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
C
7F
Change the data and set the
Cr signal level (A) to the
specified value.
Cr signal level (A) to the
specified value.
3
C
7F
Press PAUSE (Write) button.
4
C
26
Set a value obtained by
adding 5 to the
fore mentioned data, and
press PAUSE (Write) button.
adding 5 to the
fore mentioned data, and
press PAUSE (Write) button.
5
C
80
Change the data and set the
Cb signal level (B) to the
specified value.
Cb signal level (B) to the
specified value.
6
C
80
Press PAUSE (Write) button.
7
C
27
Set a value obtained by
adding 3 to the
fore mentioned data, and
press PAUSE (Write) button.
adding 3 to the
fore mentioned data, and
press PAUSE (Write) button.
8
Check the burst signal (C) to
the specified value.
the specified value.
9
Perform “Processing after
Complete Adjustment”.
Complete Adjustment”.
H
A
B
0.23
μ
sec
0.23
μ
sec
C
6-62
DCR-VX2200E_ADJ
1-5. Processing after Complete Adjustment
Perform the setting through the procedure mentioned below when
you finish the “S VIDEO, VIDEO OUT Adjustment”.
you finish the “S VIDEO, VIDEO OUT Adjustment”.
Order Page Address Data
Procedure
1
0
10
01
2
C
0F
00
Press PAUSE (Write) button.
(1C)
3
8
04
80
Press PAUSE (Write) button.
(18)
4
8
00
00
Press PAUSE (Write) button.
(18)
5
8
01
00
Press PAUSE (Write) button.
(18)
6
8
06
00
Press PAUSE (Write) button.
(18)
7
0
10
00
8
3
70
10
Press PAUSE (Write) button.
9
3
70
Check the data changes to
“11”.
“11”.
10
7
83
00
11
0
01
00
1-4. VIDEO OUT Level Check (VC-597 board)
Mode
VCR mode
Signal
No signal
Measurement Point
VIDEO OUT plug of A/V Remote
connector (75
connector (75
Ω terminated)
Measuring Instrument
Oscilloscope
Specified value
Sync level: A = 300
± 18 mVp-p
Burst level: B = 300
± 18 mVp-p
Checking method:
Order Page Address Data
Procedure
1
Perform “Preparations”
2
Check the sync signal level
(A) to the specified value.
(A) to the specified value.
3
Check the burst signal level
(B) to the specified value.
(B) to the specified value.
4
Perform “Processing after
Complete Adjustment”.
Complete Adjustment”.
Fig. 6-3-5
H
B
A
3-4-2. COMPONENT VIDEO OUT Adjustment
2-1. Preparations
2-1. Preparations
Perform the following data setting before the “COMPONENT
VIDEO OUT Adjustment”.
VIDEO OUT Adjustment”.
Order Page Address Data
Procedure
1
Set the unit to VCR mode.
2
0
01
01
3
07
01
BD
(Set to HDV Mode)
4
07
04
00
5
07
02
FF
6
07
00
01
Press PAUSE (Write) button.
7
07
02
Check the data is “01”.
8
07
01
D1
(Component D3 setting)
9
07
04
02
10
07
00
01
Press PAUSE (Write) button.
11
07
02
Check the data is “01”.
6-63
DCR-VX2200E_ADJ
H
A
C
B
2-2. COMPONENT OUT Y Level Adjustment
(VC-597 board)
Mode
CAMERA mode
Subject
Arbitrary
Measurement Point
Y signal terminal of COMPONENT
OUT plug of A/V Remote connector
(75
OUT plug of A/V Remote connector
(75
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
8C
Specified value
Y level: A = 1000
± 10 mVp-p
Sync level: B = C = 300
± 10 mVp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
7
83
02
3
3
71
01
Press PAUSE (Write) button.
4
0
10
01
5
8
5C
Set the bit value of bit0 is
(18)
“1”, and press PAUSE
(Write) button. (Note)
(Write) button. (Note)
6
8
5D
05
Press PAUSE (Write) button.
(18)
7
0
10
00
8
C
8C
Change the data and set the Y
signal level (A) to the
specified value.
signal level (A) to the
specified value.
8
C
8C
Press PAUSE (Write) button.
10
Check the sync signal (B, C)
to the specified value.
to the specified value.
11
0
10
01
12
8
5C
Set the bit value of bit0 is
(18)
“0”, and press PAUSE
(Write) button. (Note)
(Write) button. (Note)
13
8
5D
00
Press PAUSE (Write) button.
(18)
14
0
10
00
15
3
70
10
Press PAUSE (Write) button.
16
3
70
Check the data changes to
“11”.
“11”.
17
7
83
00
18
0
01
00
Note:
For the bit values, refer to “6-4. SERVICE MODE”, “4-4.
3. Bit value discrimination”.
3. Bit value discrimination”.
Fig. 6-3-6
2-3. COMPONENT OUT Pr Level Adjustment
(VC-597 board)
Mode
CAMERA mode
Subject
Arbitrary
Measurement Point
P
r
/C
r
signal terminal of COMPO-
NENT OUT plug of A/V Remote
connector (75
connector (75
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
8E
Specified value
Pr level: A = 525
± 10 mVp-p
Sync level: B = C = 300
± 10 mVp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
7
83
02
3
3
71
01
Press PAUSE (Write) button.
4
0
10
01
5
8
5C
Set the bit value of bit0 is
(18)
“1”, and press PAUSE
(Write) button. (Note)
(Write) button. (Note)
6
8
5D
05
Press PAUSE (Write) button.
(18)
7
0
10
00
8
C
8E
Change the data and set the
Pr signal level (A) to the
specified value.
Pr signal level (A) to the
specified value.
9
C
8E
Press PAUSE (Write) button.
10
Check the sync signal (B, C)
to the specified value.
to the specified value.
11
0
10
01
12
8
5C
Set the bit value of bit0 is
(18)
“0”, and press PAUSE
(Write) button. (Note)
(Write) button. (Note)
13
8
5D
00
Press PAUSE (Write) button.
(18)
14
0
10
00
15
3
70
10
Press PAUSE (Write) button.
16
3
70
Check the data changes to
“11”.
“11”.
17
7
83
00
18
0
01
00
Note:
For the bit values, refer to “6-4. SERVICE MODE”,
“4-4. 3. Bit value discrimination”.
“4-4. 3. Bit value discrimination”.
Fig. 6-3-7
H
A
C
B
Click on the first or last page to see other DCR-VX2200E (serv.man2) service manuals if exist.