Movie / SECTION 6 ADJUSTMENTS
File
dcr-vx2200e-sm2.pdf
Date

Sony DCR-VX2200E (serv.man2) Service Manual ▷ View online

6-32
DCR-VX2200E_ADJ
12. Auto White Balance Standard Data Input
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart (Color reproduction
adjustment frame)
Adjustment Page
6F
Adjustment Address
88 to 8B
Note 1:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) D.EXTENDER (Menu setting) ....................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
99
Check the data is “00”.
3
6
02
Check the data is “00”.
4
6
07
Check the data is “04”.
5
6
61
01
6
Wait for 3 seconds.
7
6
40
01
8
6
41
01
9
6
01
0B
Press PAUSE (Write) button.
(Note 3)
10
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
6F, address: 88 to 8B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
40
00
3
6
41
00
4
6
61
00
5
0
01
00
13. LV Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the normal coefficient of the light value at 3200K.
Adjustment Page
6D
Adjustment Address
5C, 5D
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: D (6D), address: 5C and 5D.
Note:
Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
5C
36
5D
2B
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
14. STD GAIN Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Correct a variation in the CMOS sensitivity setting.
As the CMOS sensitivity is dominant on the variation, correct it
with the AGC_GAIN standard setting.
Adjustment Page
6D
Adjustment Address
5A
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: D (6D), address: 5A.
Note:
Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
5A
1E
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
15. MAX GAIN Adjustment 
RadarW
RadarW
RadarW
Correct a variation in the CMOS sensitivity setting.
As the CMOS sensitivity is dominant on the variation, correct it
with the AGC_GAIN standard setting.
Adjustment Page
6D
Adjustment Address
5E, 5F
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: D (6D), address: 5E and 5F.
Note:
Press the PAUSE (Write) button of the adjustment remote com-
mander each time to set data.
Address
Data
5E
0B
5F
6E
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
6-33
DCR-VX2200E_ADJ
16. Auto White Balance Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart
(Color reproduction adjustment
frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
6F
Adjustment Address
84 to 87, 98 to 9B
Note 1:
Perform “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
If reading/writing data on page 6F, set data: 06 to page:
0, address: 10, and then select pages: D, F. By this data
setting, the page 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
0
01
01
3
6
99
Check the data is “00”.
4
6
02
Check the data is “00”.
5
6
07
Check the data is “04”.
6
6
61
01
7
Wait for 3 seconds.
8
6
40
01
9
6
41
01
10
0
10
06
11
F
84
2A
Press PAUSE (Write) button.
(6F)
12
F
85
E7
Press PAUSE (Write) button.
(6F)
13
F
86
5B
Press PAUSE (Write) button.
(6F)
14
F
87
5C
Press PAUSE (Write) button.
(6F)
15
0
10
00
16
6
01
81
Press PAUSE (Write) button.
(Note 4)
17
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
6F, address: 98 to 9B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
40
00
3
6
41
00
4
6
61
00
5
0
01
00
6
Remove the C14 filter on the
lens.
6-34
DCR-VX2200E_ADJ
17. Auto White Balance Check 
RadarW
RadarW
RadarW
Subject
Clear chart (Color reproduction
adjustment frame)
Filter
ND filter 1.0, 0.4 and 0.1
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified Value
Data of page: 6, address: 0C is “00”
Note 1:
Perform “Auto White Balance Standard Data Input”, “LV
Standard Data Input” and “Auto White Balance Adjust-
ment” before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Checking method:
Order Page Address Data
Procedure
1
0
01
01
2
6
9B
Check the bit value of bit2 is
“0”. (Note 3)
3
6
99
Check the data is “00”.
4
6
07
Check the data is “04”.
5
6
61
01
6
Wait for 3 seconds.
7
6
40
01
8
6
41
01
9
6
CA
85
10
6
C9
10
 
OUTDOOR white balance check
11
6
01
4F
Press PAUSE (Write) button.
12
6
02
Check the data changes to
“01”.
13
6
0C
Check the data is “00”.
14
6
01
00
Press PAUSE (Write) button.
 
INDOOR white balance check
15
6
01
0F
Press PAUSE (Write) button.
16
6
02
Check the data changes to
“01”.
17
6
0C
Check the data is “00”.
18
6
01
00
Press PAUSE (Write) button.
19
6
61
00
20
Wait for 3 seconds.
Order Page Address Data
Procedure
 
 InOut check
21
Place the ND filter 1.5 (1.0
+0.4 + 0.1) on the lens.
22
6
C9
11
23
6
01
4B
Press PAUSE (Write) button.
24
6
02
Check the data changes to
“01”.
25
6
0C
Check the data is “00”.
26
6
01
00
Press PAUSE (Write) button.
27
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Note 3:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
C9
00
2
6
CA
00
4
6
40
00
6
6
41
00
7
0
01
00
6-35
DCR-VX2200E_ADJ
18. Color Reproduction Adjustment 
RadarW
RadarW
RadarW
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment
frame)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
B0 to B7, A8 to AF
Specified Value
Data of page: 6 address: 0C is “00”
Note 1:
Perform “Linear Matrix Adjustment” and “Auto White
Balance Standard Data Input” before this adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
99
Check the data is “00”.
3
6
02
Check the data is “00”.
4
6
9B
Check the bit value of bit2 is
“0”. (Note 4)
5
6
9B
Check the bit value of bit3 is
“0”. (Note 4)
6
6
07
Check the data is “04”.
7
6
15
A0
8
6
61
01
9
Wait for 3 seconds.
10
6
40
01
11
6
41
01
12
6
C9
10
13
6
CA
04
14
6
D0
35
15
6
01
61
Press PAUSE (Write) button.
(Note 5)
16
6
02
Check the data changes to
“01”.
17
6
0C
Check the data is “00”.
Note 4:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Note 5:
The adjustment data will be automatically input to page:
6F, address: B0 to B7, A8 to AF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
C9
00
3
6
CA
00
4
6
40
00
5
6
41
00
6
6
15
00
7
6
61
00
8
0
01
00
Page of 80