Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-vx2200e-sm2.pdf
Date

Sony DCR-VX2200E (serv.man2) Service Manual ▷ View online

6-24
DCR-VX2200E_ADJ
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. (Except Origin Oscillation Check”)
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
1-3-1.
Camera System Adjustments
1.
Origin Oscillation Check (VC-597 board)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
R1414 (CHCK) on VC-597 board
Measuring Instrument
Frequency counter
Specified value
f = 4.433619 MHz 
± 835 Hz
Switch setting
1) POWER ......................................................... CAMERA mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
Fig. 6-1-5
IC1401
R1414
VC-597 BOARD (SIDE A)
IC1601
2.
Coaxial Harness Connecting Check 
RadarW
RadarW
RadarW
RadarW
RadarW
Check if the coaxial harness of CMOS is connected correctly.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6
Adjustment Address
D1 to D6
Specified value
Data of page: 6, address: D0 is “07”
Note 1:
Check that the data of page: 6, address: 02 is “00”
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
07
Check the data is “04”.
3
0
10
09
4
E
90
10
(9E)
5
E
80
00
(9E)
6
0
10
00
7
6
01
EB
Press PAUSE (Write)
button.(Note 2)
8
6
02
Check the data changes to
“01”.
9
6
D0
Check the data is “07”.
(Note 3)
Note 2:
The adjustment data will be automatically input to page:
6, address: D1 to D6.
Note 3:
For the error codes of bit 0 to bit 2 of data of page: 6,
address: D0, see the following table.
Bit value of data of
Error contents
page: 6,
address: D0
Bit
Function
When bit value = 0 When bit value = 1
0
R
Error exists
No error
1
G
Error exists
No error
2
B
Error exists
No error
Example: If an error exists in G, data is “05”
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
10
09
3
E
90
00
(9E)
4
E
80
70
(9E)
5
0
10
00
6
0
01
00
6-25
DCR-VX2200E_ADJ
3.
PSD Sensor Gradient Adjustment (VC-597 board)
Input average offset voltage of the YAW (SE8502)/PITCH
(SE8501) sensors on GY-014 board.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
7F
Adjustment Address
00 to 1F
Specified value
Data of page: 72, address: 02 is “01”
Note 1:
Set the camera on a horizontal table.
Note 2:
Check that the data of page: 72, address: 02 is “00”
If not, select page: 72, address: 01, set data: 00, and press
the PAUSE (Write) button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
7
3
2
01
97
Press PAUSE (Write) button.
(72)
(Note 3)
4
Wait for 6 seconds.
5
2
02
Check the data changes to
(72)
“01”. (Note 4)
6
F
16
Check the data changes to
(7F)
“11”.
7
2
01
00
Press PAUSE (Write) button.
(72)
8
0
10
00
9
0
01
00
Note 3:
The adjustment data will be automatically input to page:
7F, address: 00 to 1F.
Note 4:
If the data is other than “01”, adjustment has errors.
Contents of error is written into page: 7, address: 02. See
the following table.
Data of page: 7F,
Error contents
address: 16
X, Y = 0
In the middle of adjustment
X, Y = 2
Abnormal termination
X, Y = 1
Normal termination
RadarW
RadarW
RadarW
4.
Lens Adjustment
The inner focus lens MR adjustment is carried out automatically.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
30, 40 to 4F
Specified value
Data of page: 6, address: 0C is “00”
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
Perform “Flange Back Adjustment ” after this adjustment.
Note 3:
If reading/writing data on page 6F, set data: 06 to page:
0, address: 10, and then select page F. By this data set-
ting, the page 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 4)
3
6
01
BD
Press PAUSE (Write) button.
(Note 5)
4
6
02
Check the data changes to “01”.
5
6
0C
Check the data is “00”.
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 5:
The adjustment data will be automatically input to page:
6F, address: 30, 40 to 4F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE (Write) button.
5
0
01
00
“X, Y”: X: High 4 bits (Yaw sensor)
             Y: Low 4 bits (Pitch sensor)
RadarW
RadarW
RadarW
6-26
DCR-VX2200E_ADJ
5.
Zoom Ring Adjustment (MR Sensor)
The manual zoom ring MR adjustment is carried out automati-
cally.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6D
6E
Adjustment Address
A9 to AC, AF
FC to FF
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6D, 6E, set data: 06 to
page: 0, address: 10, and then select pages D, E. By this
data setting, the pages 6D, 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 3)
Turn the zoom ring manually
in one direction slowly.
3
It should be turning several
times.
Continue to turn till the end of
adjustment.
4
6
01
5B
Press PAUSE (Write) button.
(Note 4)
5
6
02
Check the data changes to “01”.
6
Wait for 10 seconds.
7
6
0C
Check the data is “00”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 4:
The adjustment data will be automatically input to page:
6D, address: A9 to AC, AF and page: 6E, address: FC to
FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
RadarW
RadarW
RadarW
6.
Focus Ring Adjustment (MR Sensor)
The manual focus ring MR adjustment is carried out automati-
cally.
Subject
Not required
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6D
6E
Adjustment Address
A5 to A8, AD to AF
FA, FB
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6D, 6E, set data: 06 to
page: 0, address: 10, and then select pages D, F. By this
data setting, the pages 6D, 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 3)
Turn the focus ring manually
in one direction slowly.
3
It should be turning several
times.
Continue to turn till the end of
adjustment.
4
6
01
59
Press PAUSE (Write) button.
(Note 4)
5
6
02
Check the data changes to “01”.
6
Wait for 10 seconds.
7
6
0C
Check the data is “00”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 4:
The adjustment data will be automatically input to page:
6D, address: A5 to A8, AD to AF and page: 6E, address:
FA, FB.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
RadarW
RadarW
RadarW
RadarW
RadarW
6-27
DCR-VX2200E_ADJ
7.
Flange Back Adjustment
(Using the minipattern box or flange back adjustment
jig)
[Preparation (Using the minipattern box)]
1) The minipattern box is installed as shown in the following fig-
ure.
Note:
 The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Fig. 6-1-6
[Preparation (Using the flange back adjustment jig)]
(Illuminance: 550 to 650 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-7
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
7-1. Flange Back Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
(Using the minipattern box or flange back adjust-
ment jig)
Perform the flange back adjustment. In whichever case, the focus
will be deviated during auto focusing/manual focusing.
Subject
Siemens star chart for minipattern
box (Note 1) or flange back
adjustment jig
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
20 to 3F
Specified value
Data of page: 06, address: 0C is “00”
Note 1:
Dark Siemens star chart.
Note 2:
Perform “PSD Sensor Gradient Adjustment”, “Lens Ad-
justment”, “Zoom Ring Adjustment”, “Focus Ring Ad-
justment” 
before 
this adjustment.
Note 3:
Perform the adjustment with the lens in horizontal state.
Note 4:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 5:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6:
Don't touch the zoom ring during adjustment.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2011.05
Page of 80
Display

Click on the first or last page to see other DCR-VX2200E (serv.man2) service manuals if exist.