DOWNLOAD Sony DCR-VX2200E (serv.man2) Service Manual ↓ Size: 847.27 KB | Pages: 80 in PDF or view online for FREE

Model
DCR-VX2200E (serv.man2)
Pages
80
Size
847.27 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-vx2200e-sm2.pdf
Date

Sony DCR-VX2200E (serv.man2) Service Manual ▷ View online

6-16
DCR-VX2200E_ADJ
2.
Modification of Camera Control Page Data
If the camera control page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If 2-digit page is selected, set higher-order digit to page: 0,
address: 10 as data, and then select lower-order digit by a usual
method.
e.g.: Set data: 06 to page: 0, address: 10, and then select page:
D. Thus, the page 6D can be selected.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the cam-
corder may not operate.
4) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table. If different, change them to the adjustment
initial values.
6) Select page: 0, address: 01, set data: 01.
7) Select page: 3, address: 71, set data: 01, and press PAUSE
(Write) button.
Processing after Completing Modification Camera Control
Data:
Order Page Address Data
Procedure
1
0
10
00
2
3
70
10
Press PAUSE (Write) button.
3
3
70
Check the data changes to
“11”.
4
2
00
29
5
2
01
29
Press PAUSE (Write) button.
3.
6D Page table
Note 1:
If reading/writing data on pages 6D, set data: 06 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 6D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to 59
Fixed data-1 (Initialized data)
5A
00
STD gain adj.
5B
Fixed data-1 (Initialized data)
5C
36
LV Standard data input
5D
10
5E
0B
MAX gain adj.
5F
6E
60 to F9
Fixed data-1 (Initialized data)
4.
6E Page table
Note 1:
If reading/writing data on pages 6E, set data: 06 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
5.
6F Page table
Note 1:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
10 to FF
Fixed data-1 (Initialized data)
6.
7C Page table
Note 1:
If reading/writing data on pages 7C, set data: 07 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 7C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
7.
7E Page table
Note 1:
If reading/writing data on pages 7E, set data: 07 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 7E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
6-17
DCR-VX2200E_ADJ
8.
7F Page table
Note 1:
If reading/writing data on pages 7F, set data: 07 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 7F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00
80
01
80
02
02
03
C2
04
02
05
C2
06
00
07
00
08
00
09
00
0A
00
0B
00
0C
00
0D
00
0E
00
0F
00
PSD Sensor Gradient Adjustment
10
00
11
00
12
00
13
00
14
00
15
00
16
00
17
00
18
00
19
00
1A
00
1B
00
1C
00
1D
00
1E
00
1F
00
20
60
Angular Velocity Sensor Sensitivity
21
60
Adjustment
22 to 7F
Fixed data-1 (Initialized data)
9.
8C Page table
Note 1:
If reading/writing data on pages 8C, set data: 08 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 8C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to 45
Fixed data-1 (Initialized data)
46
Fixed data-2
47 to DE
Fixed data-1 (Initialized data)
 DF
Fixed data-2
E0
Fixed data-1 (Initialized data)
E1
Fixed data-2
E2 to F9
Fixed data-1 (Initialized data)
10. 8D Page table
Note 1:
If reading/writing data on pages 8D, set data: 08 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 8D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
6-18
DCR-VX2200E_ADJ
11. 8E Page table
Note 1:
If reading/writing data on pages 8E, set data: 08 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 8E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to 08
Fixed data-1 (Initialized data)
09 to 0E
Fixed data-2
0F, 10
Fixed data-1 (Initialized data)
11 to 16
Fixed data-2
17, 18
Fixed data-1 (Initialized data)
19 to 1C
Fixed data-2
1D
Fixed data-1 (Initialized data)
1E
Fixed data-2
1F, 20
Fixed data-1 (Initialized data)
21 to 24
Fixed data-2
25
Fixed data-1 (Initialized data)
26
Fixed data-2
27, 28
Fixed data-1 (Initialized data)
29 to 2C
Fixed data-2
2D
Fixed data-1 (Initialized data)
2E
Fixed data-2
2F to 38
Fixed data-1 (Initialized data)
39 to 3E
Fixed data-2
3F, 40
Fixed data-1 (Initialized data)
41 to 44
Fixed data-2
45 to 48
Fixed data-1 (Initialized data)
49
Fixed data-2
4A to 50
Fixed data-1 (Initialized data)
51
Fixed data-2
52 to 58
Fixed data-1 (Initialized data)
59
Fixed data-2
5A to 66
Fixed data-1 (Initialized data)
67
Fixed data-2
68 to 7E
Fixed data-1 (Initialized data)
7F
Fixed data-2
80 to FF
Fixed data-1 (Initialized data)
12. 8F Page table
Note 1:
If reading/writing data on pages 8F, set data: 08 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 8F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00
Fixed data-1 (Initialized data)
01 to 05
Fixed data-2
06 to 08
Fixed data-1 (Initialized data)
09
Fixed data-2
0A to 0F
Fixed data-1 (Initialized data)
10
Fixed data-2
11, 12
Fixed data-1 (Initialized data)
13
Fixed data-2
14 to 32
Fixed data-1 (Initialized data)
33
Fixed data-2
34
Fixed data-1 (Initialized data)
35
Fixed data-2
36 to 38
Fixed data-1 (Initialized data)
39
Fixed data-2
3A
Fixed data-1 (Initialized data)
3B
Fixed data-2
3C to 77
Fixed data-1 (Initialized data)
78 to 7A
Fixed data-2
7B to 7D
Fixed data-1 (Initialized data)
7E, 7F
Fixed data-2
80 to 8F
Fixed data-1 (Initialized data)
90, 91
Fixed data-2
92 to A3
Fixed data-1 (Initialized data)
A4, A5
Fixed data-2
A6 to C1
Fixed data-1 (Initialized data)
C2
Fixed data-2
C3 to E1
Fixed data-1 (Initialized data)
E2
Fixed data-2
E3
Fixed data-1 (Initialized data)
E4, E5
Fixed data-2
E6 to FF
Fixed data-1 (Initialized data)
6-19
DCR-VX2200E_ADJ
13. 9D Page table
Note 1:
If reading/writing data on pages 9D, set data: 09 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 9D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to 4F
Fixed data-1 (Initialized data)
14. 9E Page table
Note 1:
If reading/writing data on pages 9E, set data: 09 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 9E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
15. 9F Page table
Note 1:
If reading/writing data on pages 9F, set data: 09 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 9F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
16. AD Page table
Note 1:
If reading/writing data on pages AD, set data: 0A to page:
0, address: 10, and then select pages: D. By this data
setting, the pages AD can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to 4F
Fixed data-1 (Initialized data)
17. AE Page table
Note 1:
If reading/writing data on pages AE, set data: 0A to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages AE can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to 7B
Fixed data-1 (Initialized data)
7C, 7D
Fixed data-2
7E to F1
Fixed data-1 (Initialized data)
18. AF Page table
Note 1:
If reading/writing data on pages AF, set data: 0A to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages AF can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
19. BE Page table
Note 1:
If reading/writing data on pages BE, set data: 0B to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages BE can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the Camera Control Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of Camera Control Data”)
Address
Initial value
Remark
00 to CA
Fixed data-1 (Initialized data)
CB to D0
Fixed data-2
D1 to F9
Fixed data-1 (Initialized data)
Page of 80
Display