Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv345e-dcr-trv350-dcr-trv351-dcr-trv355e-dcr-.pdf
Date

Sony DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) Service Manual ▷ View online

6-66
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
00 to 0C
COLOR SLOW
S/SUPER NS
(FK-3000 block)
(S001)
FOCUS
(CF-3000 block)
(S007)
PAUSE
(FK-3000 block)
(S003)
PB ZOOM
(CF-3000 block)
(S003)
DELETE
(CF-3000 block)
(S004)
PHOTO
(START)
(SS-3000 block)
(S004)
START/STOP
(SS-3000 block)
(S002)
6. Switch Check (3)
Page 2
Address 60 to 65, 67
Using method:
1) Select page: 2, address: 60 to 65, 67.
2) By discriminating the display data, the pressed key can be discriminated.
7. LED, Video Light, IR Light Check
Using method:
1) Set the unit to camera mode.
2) Select page: 7, address: 07, and set the bit value of bit5 to “1”.
3) Check that all LED are lit, that the IR light is lit, and that the video light is lit.
4) Select page: 7, address: 07, and set the bit value of bit5 to “0”.
Page 7
Address 07
Bit5
Address
60
(KEY AD0)
(IC5001 
tl
)
61
(KEY AD1)
(IC5001 
y;
)
62
(KEY AD2)
(IC5001 
ya
)
63
(KEY AD3)
(IC5001 
yg
)
64
(KEY AD4)
(IC5001 
yh
)
65
(KEY AD5)
(IC5001 
yj
)
67
(KEY AD7)
(IC5001 
yl
)
0D to 24
LIGHT
(FK-3000 block)
(S004)
BACKLIGHT
(CF-3000 block)
(S009)
END
SEARCH
(CF-3000 block)
(S008)
EXPOSURE
(CF-3000 block)
(S005)
MPEG PLAY
(CF-3000 block)
(S006)
25 to 3F
STOP
(FK-3000 block)
(S005)
FADER
(CF-3000 block)
(S014)
MENU
EXECUTE
(CF-3000 block)
(S023)
TITLE
(CF-3000 block)
(S010)
MEMORY MIX
(CF-3000 block)
(S011)
40 to 5D
FF
(FK-3000 block)
(S006)
EDIT
SEARCH –
(CF-3000 block)
(S017)
VOLUME +
(CF-3000 block)
(S019)
MENU
(CF-3000 block)
(S012)
INDEX
(CF-3000 block)
(S013)
5E to 81
REW
(FK-3000 block)
(S007)
EDIT
SEARCH +
(CF-3000 block)
(S018)
VOLUME –
(CF-3000 block)
(S021)
DISPLAY
(CF-3000 block)
(S015)
MEMORY +
(CF-3000 block)
(S016)
PANEL
REVERSE
(RF-3000 block)
(S601)
82 to AA
PLAY
(FK-3000 block)
(S008)
PANEL
CLOSE
(CF-3000 block)
(S001)
MEMORY –
(CF-3000 block)
(S020)
AB to D7
REC
(FK-3000 block)
(S009, S010)
PLAY
(MEMORY)
(CF-3000 block)
(S022)
D8 to FF
No key input
No key input
No key input
PANEL
OPEN
(CF-3000 block)
(S001)
No key input
PANEL
NORMAL
(PR-3000 block)
(S601)
No key input
Data
6-67
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
8. Record of Use Check
Page 7
Address A7 to A9, C8 to CF
Using method:
1) The record of use data is displayed at page: 7, addresses: A7 to
A9 and C8 to CF.
Note 1:
 This data will be erased (reset) when the cabinet (R) as-
sembly (VC-305 board CN1007 (18P)) is removed.
Note 2:
When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3:
When replacing the video light, initialize the data of ad-
dress: CE and CF.
Note 4:
Video light counted time is indicated in hexadecimal
notation. Convert hexadecimal numbers to decimals be-
fore useing them.
Initializing method of drum rotation counted time:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 7, address: A7, set data: 00, and press the PAUSE
button.
3) Select address: A8 and A9 and set data “00” into them in the
same way as in address: A7.
4) Select page: 0, address: 01, and set data: 00.
Address
A7
A8
A9
C8
C9
CA
CB
CC
CD
CE
CF
Function
Drum rotation
Hour
counted time
Hour
(BCD code)
Hour
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence date
Month
(BCD code)
Day
Video light
Hour (H)
counted time (Note 4)
Hour (L)
Remarks
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
After setting the clock, set the date of power on next
1000th place digit and 100th place digit of counted time (hexadecimal digit)
10th place digit and 1st place digit of counted time (hexadecimal digit)
6-68
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
Address
B0
B1
B2
B4
B5
B6
B8
B9
BA
BC
BD
BE
C0
C1
C2
C4
C5
C6
Self-diagnosis code
“Repaired by” code (Occurred 1st time)   *1
“Block function” code (Occurred 1st time)
“Detailed” code (Occurred 1st time)
“Repaired by” code (Occurred 2nd time)   *1
“Block function” code (Occurred 2nd time)
“Detailed” code (Occurred 2nd time)
“Repaired by” code (Occurred 3rd time)   *1
“Block function” code (Occurred 3rd time)
“Detailed” code (Occurred 3rd time)
“Repaired by” code (Occurred 4th time)   *1
“Block function” code (Occurred 4th time)
“Detailed” code (Occurred 4th time)
“Repaired by” code (Occurred 5th time)   *1
“Block function” code (Occurred 5th time)
“Detailed” code (Occurred 5th time)
“Repaired by” code (Occurred the last time)   *1
“Block function” code (Occurred the last time)
“Detailed” code (Occurred the last time)
9. Record of Self-diagnosis Check
Page 7
Address B0 to C6
*1 : “01” 
t “C”, “03” t “E”
Using method:
1) The past self-diagnosis codes are displayed at page: 7, ad-
dress: B0 to C6. Refer to “SELF-DIAGNOSIS FUNCTION”
for detail of the self-diagnosis code.
Note:
This data will be erased (reset) when the cabinet (R)
assembly (VC-305 board CN1007 (18P)) is removed.
6-69
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
FOR CAMERA OPTICAL AXIS ADJUSTMENT
0
180
90
67.5
22.5
337.5
292.5
247.5
202.5
157.5
112.5
8
4
5
7
1
6
2
3
270
Take a copy of OPTICAL AXIS
FRAME with a clear sheet for use.
Page of 73