DOWNLOAD Sony DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) Service Manual ↓ Size: 1.02 MB | Pages: 73 in PDF or view online for FREE

Model
DCR-TRV345E DCR-TRV350 DCR-TRV351 DCR-TRV355E DCR-TRV356E (serv.man4)
Pages
73
Size
1.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv345e-dcr-trv350-dcr-trv351-dcr-trv355e-dcr-.pdf
Date

Sony DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) Service Manual ▷ View online

6-42
COVER
COVER
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
2-2-3. OVERALL TAPE PATH CHECK
1. Recording of the tape path check signal
1) Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2) Connect the adjustment remote commander to the LANC jack.
3) Turn the HOLD switch of the adjustment remote commander
to the ON position.
4) Set to the camera recording mode.
5) Select page: 3, address: 1C, set data: 5D, and press the PAUSE
button of the adjustment remote commander.
6) Record for several minutes.
7) Release the camera recording mode.
8) Select page: 3, address: 1C, set data: 00, and press the PAUSE
button.
2. Tape path check
1) Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2) Connect the adjustment remote commander to the LANC jack.
3) Turn the HOLD switch of the adjustment remote commander
to the ON position.
4) Connect the oscilloscope to I/F unit for LANC control.
Channel 1: PB RF (MON) (Pin 9 of CN1011)
Channel 2 (Trigger) : SWP (Pin 5 of CN1011)
Note:
Connect a 75 
Ω resistor between PB RF (MON) and
GND.
5) Select page: 7, address: 62, and set data: 01.
6) Playback the tape path check signal.
7) Select page: 3, address: 33, and set data: 08.
8) Select page: 3, address: 26, and set data: 31.
9) Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, perform “2-1-2. TAPE PATH ADJUSTMENT “ of
“2-1. Hi8/STANDARD 8 mm MODE”.
10) Select page: 3, address: 26, and set data: 00.
11) Select page: 3, address: 33, and set data: 00.
12) Select page: 7, address: 62, and set data: 00.
2-2.
DIGITAL8 MODE
2-2-1. HOW TO ENTER RECORD MODE WITHOUT
          CASSETTE
1) Connect the adjustment remote commander to the LANC jack.
2) Turn the HOLD switch of the adjustment remote commander
to the ON position.
3) Close the cassette compartment without the cassette.
4) Select page: 3, address: 01, and set data: 0C, and press the
PAUSE button of the adjustment remote commander.
(The mechanism enters the record mode automatically)
Note:
 The function buttons becomes inoperable.
5) To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote com-
mander. (Whenever you want to quit the record mode, be sure
to quit following this procedure)
2-2-2. HOW TO ENTER PLAYBACK MODE WITHOUT
          CASSETTE
1) Connect the adjustment remote commander to the LANC jack.
2) Turn the HOLD switch of the adjustment remote commander
to the ON position.
3) Close the cassette compartment without the cassette.
4) Select page: 3, address: 01, and set data: 0B, and press the
PAUSE button of the adjustment remote commander.
(The mechanism enters the playback mode automatically)
Note:
 The function buttons becomes inoperable.
5) To quit the playback mode, select page: 3, address: 01, set
data: 00, and press the PAUSE button of the adjustment re-
mote commander. (Whenever you want to quit the playback
mode, be sure to quit following this procedure)
Must be flat
CN2
(Trigger)
CH1
Fig. 6-2-2
6-43
COVER
COVER
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
6-3. VIDEO SECTION ADJUSTMENTS
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section adjust-
ments.
Note:
NTSC model: DCR-TRV350/TRV351
PAL model: DCR-TRV345E/TRV355E/TRV356E
3-1-1. Equipment to Required
1) TV monitor
2) Oscilloscope (dual-phenomenon, band width above 30 MHz
with delay mode) (Unless specified otherwise, use a 10 : 1
probe)
3) Frequency counter
4) Digital voltmeter
5) Audio level meter
6) Audio distortion meter
7) Audio generator
8) Audio attenuator
9) Regulated power supply
10) Digital8 alignment tapes
• SW/OL standard (WR5-2D)
Parts code: 8-967-993-22
• Audio operation check for NTSC (WR5-3ND)
Parts code: 8-967-993-32
• System operation check for NTSC (WR5-5ND)
Parts code: 8-967-993-42
• Audio operation check for PAL (WR5-3CD)
Parts code: 8-967-993-37
• System operation check for PAL (WR5-5CD)
Parts code: 8-967-993-47
11) NTSC Hi8/Standard8 alignment tapes
• For tracking adjustment (WR5-1NP)
Parts code: 8-967-995-02
• For video frequency characteristics adjustment (WR5-7NE)
Parts code: 8-967-995-13
• For checking Standard 8 mode operations
For LP (WR5-4NL)
Parts code: 8-967-995-51
For SP (WR5-5NSP)
Parts code: 8-967-995-42
Note:
The following alignment tapes can also be used.
WR5-4NSP (8-967-995-41)
• For checking Hi8 mode operations
For LP (WR5-8NLE)
Parts code: 8-967-995-52
For SP (WR5-8NSE)
Parts code: 8-967-995-43
• For BPF adjustment (WR5-11NS)
Parts code: 8-967-995-71
12) PAL Hi8/Standard8 alignment tapes
• For tracking adjustment (WR5-1CP)
Parts code: 8-967-995-07
• For video frequency characteristics adjustment (WR5-7CE)
Parts code: 8-967-995-18
• For checking Standard 8 mode operations
For LP (WR5-4CL)
Parts code: 8-967-995-56
For SP (WR5-5CSP)
Parts code: 8-967-995-47
Note:
The following alignment tapes can also be used.
1) WR5-3CL (8-967-995-36)
2) WR5-4CSP (8-967-995-46)
• For checking Hi8 mode operations
For LP (WR5-8CLE)
Parts code: 8-967-995-57
For SP (WR5-8CSE)
Parts code: 8-967-995-48
• For BPF adjustment (WR5-11CS)
Parts code: 8-967-995-76
13) Adjustment remote commander (J-6082-053-B)
14) CPC jig connector (J-6082-539-A)
15) I/F unit for LANC control (J-6082-521-A)
6-44
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
3-1-2.
Precautions on Adjusting
1) The adjustments of this unit are performed in the VTR mode
or camera mode.
To set to the VTR mode, set the power switch to “PLAYER”
or set the “Forced VTR Power ON mode” using the adjust-
ment remote commander (Note 1).
To set to the Camera mode, set the power switch to “CAM-
ERA” or set the “Forced Camera Power ON mode” using the
adjustment remote commander (Note 2).
After completing adjustments, be sure to exit the “Forced VTR
Power ON Mode” or “Forced Camera Power ON Mode”. (Note
4).
2) As removing the cabinet (R) assembly (removing CN1007 of
the VC-305 board) means removing the lithium 3 V power
supply (CF-3000 block BT001), data such as date, time, user-
set menus will be lost. After completing adjustments, reset these
data. If the cabinet (R) assembly has been removed, the self-
diagnosis data, data on history of use (total drum rotation time
etc.) will be lost. Before removing, note down the self-diagno-
sis data (data of page: 7, address: B0 to C6) and the data on
history use (data of page: 7, address: A7 to A9 and C8 to CF).
(Refer to “6-4.Service Mode”.)
3) The cabinet (R) assembly (CF-3000 block, FK-3000 block,
PD-181 board, LCD block) need not be connected to operate
the VTR block. (Note 5) When removing the cabinet (R) as-
sembly, disconnect the following connectors.
1. VC-305 board CN1007 (18P, 0.5 mm)
2. VC-305 board CN1003 (20P, 0.8 mm)
4) The lens block (CD-418 board) need not be connected. To re-
move, disconnect the following connectors.
1. VC-305 board CN1501 (14P, 0.5 mm)
2. VC-305 board CN1551 (24P, 0.5 mm)
5) The EVF block need not be connected. To remove, disconnect
the following connectors.
VC-305 board CN1005 (20P, 0.5 mm)
6) The memory stick slot need not be connected. To remove, dis-
connect the following connector.
VC-305 board CN1013 (10P, 0.5 mm)
7) By setting the “Forced VTR Power ON mode” or “Forced Cam-
era Power ON mode”, the video section can be operate even if
the control switch block (SS-3000) has been removed. When
removing the control switch block (SS-3000), disconnect the
following connector.
VC-305 board CN1009 (12P, 0.8 mm)
Note 1:
Setting the “Forced VTR Power ON” mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press
the PAUSE button.
The above procedure will enable the VTR power to be
turned on with the control switch block (SS-3000) re-
moved.
After completing adjustments, be sure to exit the “Forced
VTR Power ON mode”.
Note 2:
Setting the “Forced Camera Power ON” mode (Camera
mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press
the PAUSE button.
The above procedure will enable the camera power to be
turned on with the control switch block (SS-3000) re-
moved.
After completing adjustments, be sure to exit the “Forced
Camera Power ON mode”.
Note 3:
Setting the “Forced Memory Power ON” mode (Memory
mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 05, and press
the PAUSE button.
The above procedure will enable the camera power to be
turned on with the control switch block (SS-3000) re-
moved.
After completing adjustments, be sure to exit the “Forced
Memory Power ON mode”.
Note 4:
Exiting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press
the PAUSE button.
3) Select page: 0, address: 01, and set data: 00.
Note 5:
When the FK-3000 block or the CF-3000 block is re-
moved, the VTR does an unusual movement for one
minute after the power is turned on. So, operate the VTR
by the adjustment remote commander (with the HOLD
switch set in the OFF position) after it passes for more
than one minute.
6-45
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
3-1-3. Adjusting Connectors
Some of the adjusting points of the video section are concentrated
at VC-305 board CN1011. Connect the measuring instruments via
I/F unit for LANC control (J-6082-521-A) and CPC jig connector
(J-6082-539-A).
The following table shows the pin No. and signal name of CN1011.
Pin No.
Signal Name
Pin No.
Signal Name
1
FRRV
9
RF MON
2
8 mm PB RF
10
REG GND
3
BPF MONI
11
N. C.
4
CAP FG
12
N. C.
5
RF SWP
13
XLANC POWER ON
6
REG GND
14
EVF VG
7
XLANC JACK IN
15
VCO
8
REG GND
16
LANC SIG
Table 6-3-1
The following table lists the test point of I/F unit of for LANC
control.
Pin No.
Signal Name
Pin No.
Signal Name
BL
15
EVF VCO
14
EVF VG
BL 4.75
9
PB RF (MON)
3
BPF MONI
6, 8, 10
GND
TMS
7
REC RF (RF IN)
TDI
TDO
5
SWP
TCK
4
CAP FG
2
IR VIDEO
Note:
 Pin No. are those of CN1011.
Table 6-3-2
3-1-4. Connecting the Equipment
Connect the measuring instruments as shown in Fig. 6-3-2 and
perform the adjustments.
Fig. 6-3-1
Connecting the TV Monitor and Adjustment Remote Commander
Fig. 6-3-2
Video
(yellow)
Color monitor
Audio R (red)
Audio L (white)
I/F unit for LANC control
(J-6082-521-A)
CPC jig connector
(J-6082-539-A)
Adjustment
remote commander
LANC jack
A/V jack
MAIN UNIT
VC-305 BOARD
CN1011
CN1011
16
1
Conductor 
side
Page of 73
Display

Click on the first or last page to see other DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) service manuals if exist.