Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv345e-dcr-trv350-dcr-trv351-dcr-trv355e-dcr-.pdf
Date

Sony DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) Service Manual ▷ View online

6-54
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
3.
S VIDEO OUT C Level Adjustment (VC-305 board)
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Chroma signal terminal of
S VIDEO jack (75 
Ω terminated)
External trigger: Y signal terminal of
S VIDEO jack (75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified value
Cr level: A = 714 
± 14 mVp-p (NTSC)
A = 700 
± 14 mVp-p (PAL)
Cb level:B = 714 
± 14 mVp-p (NTSC)
B = 700 
± 14 mVp-p (PAL)
Burst level: C = 286 
± 6 mVp-p (NTSC)
C = 300 
± 6 mVp-p (PAL)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
NTSC model: DCR-TRV350/TRV351
PAL model: DCR-TRV345E/TRV355E/TRV356E
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
8
A0
Set the bit value of bit 3 to “1”,
and press PAUSE button.
(Note 3)
3
3
0C
02
Press PAUSE button.
4
C
26
Change the data and set the
Cr signal level (A) to the
specified value.
5
C
26
Press PAUSE button.
6
C
27
Change the data and set the
Cb signal level (B) to the
specified value.
7
C
27
Press PAUSE button.
8
Check the burst signal (C) to
the specified value.
9
8
A0
Set the bit value of bit 3 to “0”,
and press PAUSE button.
(Note 3)
10
3
0C
00
Press PAUSE button.
11
0
01
00
Note 3:
For the bit values, refer to  “6-4. SERVICE MODE”, “4-
3. 3. Bit Value Discrimination”.
Fig. 6-3-8
H
C
A
0.28 
µ
sec (NTSC)
0.23 
µ
sec (PAL)
B
0.28 
µ
sec (NTSC)
0.23 
µ
sec (PAL)
6-55
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
4. VIDEO OUT Level Check (VC-305 board)
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Video terminal of A/V jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope
Specified value
Sync level:
A = 286 
± 18 mVp-p (NTSC)
A = 300 
± 18 mVp-p (PAL)
Burst level:
B = 286 
± 18 mVp-p (NTSC)
B = 300 
± 18 mVp-p (PAL)
Checking method:
Order Page Address Data
Procedure
1
Check that the SYNC level
(A) satisfies the specified
value.
2
Check that the burst level (B)
satisfies the specified value.
Fig. 6-3-9
H
B
A
5.
Hi8/Standard8 Y/C Output Level Setting 
RadarW
RadarW
RadarW
RadarW
RadarW
(VC-305 board)
Set the Y/C signal output level during Hi8/Standard8 playback
mode.
Mode
VTR stop
Signal
No signal
Adjustment Page
C
Adjustment Address
73, 74
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Perform this adjustment when IC2201 or IC4502 is re-
placed.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
10
02
Press PAUSE button.
3
3
9E
01
4
3
A4
Check the data.
When the data is “53”, proceed
to step 5.
When the data is “03”, proceed
to step 8.
5
C
73
Set the following data and
press PAUSE button.
69: NTSC model
65: PAL model
6
C
74
Set the following data and
press PAUSE button.
64: NTSC model
72: PAL model
7
Proceed to step 10.
8
C
73
A0
Press PAUSE button.
9
C
74
Set the following data and
press PAUSE button.
AA: NTSC model
B8: PAL model
10
3
9E
00
11
D
10
00
Press PAUSE button.
12
0
01
00
6-56
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
6.
Hi8/Standard8 AFC f
0
 Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
(VC-305 board)
Adjust the pull-in range of the clock generator (IC2201) for A/D
conversion during Hi8/Standard8 playback.
Mode
VTR stop
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
9D
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
72
Specified value
The data of page: 3, address: 9D is
“7C” to ”84”.
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
72
50
Press PAUSE button.
3
D
10
02
Press PAUSE button.
4
3
0D
04
Press PAUSE button.
5
3
93
04
6
3
9E
01
7
0
FF
31
8
3
2C
Set the bit value of bit1 to “0”.
(Note 2)
9
Wait for 1 second.
10
3
2C
Set the bit value of bit1 to “1”.
(Note 2)
11
0
FF
00
12
Wait for 1.5 second.
13
3
01
60
Press PAUSE button. (Note 3)
14
3
02
Check the data changes to
“00”.
15
3
03
Check the data is “00”.
16
3
9D
Check that the data satisfied
the specified value.
17
3
0D
00
Press PAUSE button.
18
3
93
00
19
3
9E
00
20
D
10
00
Press PAUSE button.
21
0
01
00
Note 2:
For the bit value, refer to “6-4. SERVICE MODE”, “4-3.
3. Bit Value Discrimination”.
Note 3:
The adjustment data will be automatically input to page:
C, address: 72.
6-57
COVER
COVER
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
1. Hi8/Standard8 AFM BPF f
0
 Adjustment (VC-305 board)
Sets the BPF passing frequency of IC5401 so that the AFM signal
can separate from the playback RF signal properly. If deviated.
the mono/stereo mode will be differentiated incorrectly, and noises
and distortions will increase during high volume playback.
Mode
Playback
Signal
Hi8/Standard  alignment tape:
For BPF adjustment
(WR5-11NS (NTSC))
(WR5-11CS (PAL))
Measurement Point
Audio left or right terminal of A/V
jack
Measuring Instrument
Distortion meter
Adjustment Page
C
Adjustment Address
78
Specified Value
The Main and Sub channel distortion
rate should be almost the same
(within 
± 1%) and minimum.
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Set the Hi-Fi sound switch (menu display) to “2”.
3) Select page: C, address: 78, change the data and minimize the
distortion rate.
4) Press the PAUSE button of the adjustment remote commander.
5) Set the Hi-Fi sound switch (menu display) to “1”.
6) Select page: C, address: 78, change the data and minimize the
distortion rate.
7) Press the PAUSE button of the adjustment remote commander.
8) Repeat steps 2) to 7) and set the data of address: 78 so that the
distortions rates when the Hi-Fi sound switch is set to “2” and
set to “1” respectively are almost the same and minimum.
9) Press the PAUSE button of the adjustment remote commander.
10) Select page: 0, address: 01, and set data: 00.
11) Set the Hi-Fi sound switch to “STEREO”.
3-5.
AUDIO SYSTEM ADJUSTMENTS
Before performing the audio system adjustments, check that the
data of page: 0, address: 10 is “00”.
If not, select  page: 0, address: 10, and set data “00”.
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to
the video system measuring instruments as shown in Fig. 6-3-10.
[Adjustment Procedure]
1) Hi8/Standard8 AFM BPF f
0
 adjustment
2) Hi8/Standard8 AFM 1.5 MHz deviation adjustment
3) Hi8/Standard8 AFM 1.7 MHz deviation adjustment
4) Digital8 playback level check
5) Overall level characteristics check
6) Overall distortion check
7) Overall noise level check
8) Overall separation check
Fig. 6-3-10
Audio
oscillator
Attenuator
600 
600 
 (270 
 (1-249-410-11) +330 
 (1-249-411-11))
Main unit
Main unit
47 k 
47 k 
: 1-249-437-11
Audio level meter or
distortion meter
TV monitor
MIC jack
A/V jack
Left
Right
Video
Audio (L)
Audio (R)
In Recording
In Playback
Page of 73