DOWNLOAD Sony DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) Service Manual ↓ Size: 1.02 MB | Pages: 73 in PDF or view online for FREE

Model
DCR-TRV345E DCR-TRV350 DCR-TRV351 DCR-TRV355E DCR-TRV356E (serv.man4)
Pages
73
Size
1.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv345e-dcr-trv350-dcr-trv351-dcr-trv355e-dcr-.pdf
Date

Sony DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) Service Manual ▷ View online

6-62
COVER
COVER
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
4-3.
SERVICE MODE
Additional note on adjustment
Note 1:
If reading/writing data on page 18, set data: 01 to page:
0, address: 10, and then select page 8. By this data set-
ting, the page 18 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
After the completion of the all adjustments, cancel the
service mode by either of the following ways.
1) After data on page: D and 18 is restored, press the
RESET button and unplug the main power supply.
(In this case, date and time and menu setting have
been set by users are canceled. Perform resetting)
2) After data on page: D and 18 is restored, select page:
0, address: 01, and return the data to 00. And when
data on page: 2 and 3 are changed, return data to the
original condition.
1. Setting the Test Mode
Page 18
Address 12
Data
Function
00
Normal
01
Test mode
Various emergency prohibitions and releases
Drum emergency, capstan emergency, loading motor
emergency, reel emergency, tape top and end, DEW
detection
Page D
Address 10
Data
Function
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
03
Forced camera + VTR power ON
05
Forced memory power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page D and 18, the data set will be recorded in the non-
volatile memory by pressing the PAUSE button of the adjust-
ment remote commander. In this case, take note that the test
mode will not be exited even when the main power is turned off
(8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjust-
ment remote commander. And select page: 0, address: 01, and
set data: 00.
2. Emergence Memory Address
2-1. C Page Emergence Memory Address
Page C
Address F4 to FF
Address
Contents
F4
EMG code when first error occurs
F6
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
F7
Lower: MSW code to be moved when first error
occurs
F8
EMG code when second error occurs
FA
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
FB
Lower: MSW code to be moved when second error
occurs
FC
EMG code when last error occurs
FE
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
FF
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data “00” is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (F4 to F7). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note:
After completing adjustments, be sure to initialize the data
of addresses F4 to FF to “00”.
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
3
01
37
Press PAUSE button.
3
3
02
Check the data changes to
“00”.
4
0
01
00
6-63
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
2-2. EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in C
page, addresses F4, F8 and FC. The type of error indicated by the
code are shown in the following table.
Code
Emergency Type
00
No error
10
Loading motor emergency during loading
11
Loading motor emergency during unloading
22
T reel emergency during normal rotation
23
S reel emergency during normal rotation
24
T reel emergency (Short circuit between S reel
terminal and T reel terminal)
30
FG emergency at the start up of the capstan
40
FG emergency at the start up of the drum
42
FG emergency during normal rotation of the drum
6-64
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
0001=1
0111=7
0011=3
0010=2
0111=7
0101=5
0111=7
0111=7
0000=0
0111=7
0100=4
0111=7
0110=6
Mechanism position
MODE SW C
MODE SW B
MODE SW A
MSB
Unloading
Releasing lock of 
cassette campartment
LS chassis movement range
Pinch roller is pressed
Pinch roller is detached
EJECT
BL
USE
LOAD
BL
REW
BL
BL
REC/PB
BL
TURN
BL
STOP
Loading
Contents
Position at which the cassette compartment lock is released. The mechanism will not move
any further in the unloading direction.
BLANC code. Between two codes. The mechanism will not be stopped by this code while it
is operating.
EJECT completion position. When the cassette is ejected, the mechanism will stop at this
position.
Code during loading/unloading. Code that is used while the LS chassis is moving.
Normal stop position. The pinch roller separates, the tension regulator returns, and the
brakes of both reels turn on.
Position at which is used when the pendulum gear swings from S to T or from T to S.
PB, REC, CUE, REV, PAUSE, FF positions.
The pinch roller is pressed and tension regulator is on.
REW position. REW are carried at this position.
The mechanism will not move any further in the loading direction.
Mechanism Position
EJECT
BL
USE
LOAD
STOP
TURN
REC/PB
REW
MSW Code
1
7
3
2
6
4
0
5
2-3. MSW Code
• The lower parts of the data of C page, addresses F6, FA and FE
represent the MSW codes (mode switch mechanism position)
when errors occurs.
•  The upper parts of the data of C page, addresses F6, FA and FE
represent, when the mechanism position is to be moved, the
MSW codes at the start movement (when moving the loading
motor).
• The lower parts of the data of C page, addresses F7, FB and FF
represent the MSW codes  of the desired movement when the
mechanism position is to be moved.
6-65
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
3. Bit Value Discrimination
Bit values must be discriminated using the display data of the ad-
justment remote commander for the following items.  Us the table
below to discriminate if the bit value is “1” or “0”.
(Example) If the remote commander display is “8E”, bit value from
bit 7 to bit 4 can be discriminated from the column 
A
,
and those from bit 3 to bit 0 from column 
B
.
4. Switch Check (1)
Page 7
Address 0E
Using method:
1) Select page: 7, address: 0E.
2) By discriminating the bit value of display data, the state of the
switches can be discriminated.
5. Switch Check (2)
Page 7
Address 0C
Using method:
1) Select page: 7, address: 0C.
2) By discriminating the bit value of display data, the state of the
switch can be discriminated.
Page
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Display on the adjustment remote commander
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
C
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
A
B
Bit
0
1
2
3
4
5
6
7
Function
POWER SW (VTR MODE SW)
(SS-3000 block S001)
POWER SW (CAM MODE SW)
(SS-3000 block S001)
BATT INFO SW (FK-3000 block S002)
EJECT SW (SS-3000 block S003)
CC DOWN SW (Mechanism chassis)
PHOTO FREEZE SW (SS-3000 block S004)
POWER SW (MEMORY MODE SW)
(SS-3000 block S001)
When bit value = 1
OFF
OFF
OFF
OFF
OFF (UP)
OFF
OFF
When bit value = 0
ON (VCR)
ON (CAMERA)
ON
ON
ON (DOWN)
ON
ON (MEMORY)
Bit
1
2
3
Function
MIC jack (FP-575 flexible)
A/V OUT jack (FP-577 flexible)
S VIDEO jack (FP-577 flexible)
When bit value = 1
Used
Used
Used
When bit value = 0
Not used
Not used
Not used
Page of 73
Display

Click on the first or last page to see other DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) service manuals if exist.