DOWNLOAD Sony DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) Service Manual ↓ Size: 1.02 MB | Pages: 73 in PDF or view online for FREE

Model
DCR-TRV345E DCR-TRV350 DCR-TRV351 DCR-TRV355E DCR-TRV356E (serv.man4)
Pages
73
Size
1.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv345e-dcr-trv350-dcr-trv351-dcr-trv355e-dcr-.pdf
Date

Sony DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) Service Manual ▷ View online

6-34
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
2.
RGB AMP Adjustment (VC-305 board)
Set the D Range of the RGB decoder for driving the LCD to the
specified value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
Note:
Do either of the automatic adjustment or manual adjust-
ment.
2-1. Automatic Adjustment 
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Adjustment Page
C
Adjustment Address
39
Note 1:
Chack that the data of page: 0, address: 10 is “00”.
Switch setting:
1) PANEL OPEN/CLOSE ............................................... CLOSE
(LCD panel turns off)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
40
Note down the data.
3
C
40
10
Press PAUSE button.
4
3
01
50
Press PAUSE button. (Note 2)
5
3
02
Check the data changes to
“00”.
6
C
40
Set data noted down at step 2,
and press PAUSE button.
7
0
01
00
Note 2:
The adjustment data will be automatically input to page:
C, address: 39.
2-2. Manual Adjustment
Mode
CAMERA
Subject
Not required
Measurement Point
EVF VG (Pin qf of CN1011)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
39
Specified Value
A = 7.50 
± 0.10 Vp-p
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
39
Change the data and set the
voltage (A) to the specified
value.
3
C
39
Press PAUSE button.
4
0
01
00
A: Between the reversed waveform pedestal
and non-reversed waveform pedestal
Fig. 6-1-14
A
2H 
Pedestal
Pedestal
6-35
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
3.
Contrast Adjustment (VC-305 board)
Set the video signal level for driving the LCD to the specified
value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
Note:
Do either of the automatic adjustment or manual adjust-
ment.
3-1. Automatic Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Adjustment Page
C
Adjustment Address
3E
Note 1:
Chack that the data of page: 0, address: 10 is “00”.
Switch setting:
1) PANEL OPEN/CLOSE ............................................... CLOSE
(LCD panel turns off)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
40
Note down the data.
3
C
40
10
Press PAUSE button.
4
3
01
51
Press PAUSE button. (Note 2)
5
3
02
Check the data changes to
“00”.
6
C
40
Set data noted down at step 2,
and press PAUSE button.
7
0
01
00
Note 2:
The adjustment data will be automatically input to page:
C, address: 3E.
3-2. Manual Adjustment
Mode
CAMERA
Subject
Not required
Measurement Point
EVF VG (Pin qf of CN1011)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
3E
Specified Value
A = 2.55 
± 0.1 Vp-p
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
3E
Change the data and set the
voltage (A) to the specified
value.
(The data should be “00” to
“7F”)
3
C
3E
Press PAUSE button.
4
0
01
00
A
2H 
100 IRE
Pedestal
A: Between the pedestal (0 IRE) and 100 IRE
Fig. 6-1-15
6-36
COVER
COVER
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
1.
VCO Adjustment (PD-181 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
CAMERA
Subject
Not required
Measurement Point
Pin 8 of CN5502 (XHD OUT)
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
47, 48
Specified Value
f = 15734 
± 30 Hz (NTSC model)
f = 15625 
± 30 Hz (PAL model)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
NTSC model: DCR-TRV350/TRV351
                PAL model: DCR-TRV345E/TRV355E/TRV356E
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
47
Change the data and set the
frequency (f) to the specified
value.
3
C
47
Press PAUSE button.
4
C
47
Read the data and this data is
named D
47
.
5
Convert D
47
 to decimal
notation, and obtain D
47
’.
(Note 3)
6
Calculate D
48
’ using
following equations.
(decimal calculation)
D
48
’ = D
47
’ + 17 (NTSC model)
D
48
’ = D
47
’ – 17 (PAL model)
7
Convert D
48
’ to a hexadeci-
mal number, and obtain D
48
.
(Note 3, 4)
8
C
48
D
48
Press PAUSE button.
9
0
01
00
Note 3:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”
Note 4:
If D
48
’ > 255, then D
48
 = FF (NTSC model)
If D
48
’ < 0, then D
48
 = 00 (PAL model)
Pin No.
1
3
5
7
9
Signal Name
VB
VG
VR
XHD
GND
Pin No.
2
4
6
8
10
Signal Name
XVD OUT
PSIG
MAKER CHECK
XHD OUT
GND
1-5.
LCD SYSTEM ADJUSTMENTS
Before perform the LCD system adjustments, check that the data
of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Note 1:
The back light (fluorescent tube) is driven by a high volt-
age AC power supply. Therefore, do not touch the back
light holder to avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent dam-
ages caused by static electricity.
Note 3:
Set the LCD BRIGHT (Menu setting) to the center.
Set the LCD B.L. (Menu setting) to the BRT NORMAL.
Set the LCD COLOR (Menu setting) to the center.
 [Adjusting connector]
Most of the measuring points for adjusting the LCD display are
concentrated in the following connector.
CN5502 of the PD-181 board
Connect the Measuring Instruments via the multi CPC jig (J-6082-
311-A).
The following table shows the Pin No. and signal name of the
connector.
Fig. 6-1-16
Multi CPC jig
(J-6082-311-A)
PD-181 board
CN5502
6-37
DCR-TRV345E/TRV350/TRV351/TRV355E/TRV356E
3.
RGB AMP Adjustment (PD-181 board)
Set the D Range of the RGB decoder for driving the LCD to the
specified value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
CAMERA
Subject
Not required
Measurement Point
Pin 3 of CN5502 (VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
4A
Specified Value
A = 7.60 
± 0.05 Vp-p
Note 1:
This adjustment is the tracking adjustment in relation to
“Black Limit Adjustment”.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
4A
Change the data and set the
voltage (A) to the specified
value.
3
C
4A
Press PAUSE button.
4
0
01
00
5
Perform “Black Limit
Adjustment”.
2.
PSIG GRAY Adjustment (PD-181 board)
Set the PSIG signal level for driving the LCD to the specified value.
Mode
CAMERA
Subject
Not required
Measurement Point
Pin 4 of CN5502 (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
4C
Specified Value
A = 5.00 
± 0.1 Vp-p
Note:
 Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
4C
Change the data and set the
voltage (A) to the specified
value.
3
C
4C
Press PAUSE button.
4
0
01
00
A: Amplitude of PSIG signal
Fig. 6-1-17
A
2H
A: Between the reversed waveform pedestal and
non-reversed waveform pedestal
Fig. 6-1-18
Pedestal
Pedestal
A
2H
Page of 73
Display

Click on the first or last page to see other DCR-TRV345E / DCR-TRV350 / DCR-TRV351 / DCR-TRV355E / DCR-TRV356E (serv.man4) service manuals if exist.