2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
19 (Note2)
Adjustment Address
13 to 18, 92
24 to 27
Specified Value 1
D6 to DA
Specified Value 2
26 to 2A
Specified Value 3
D3 to DD
Specified Value 4
23 to 2D
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Switch setting:
POWER ....................................................... CAMERA-TAPE
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
6D
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01” within 50 sec. (Note3)
5
6
01
00
Set the data, and press PAUSE
button.
Note3: The adjustment data will be automatically input to page: F, address:
13 to 18, 92 and to page: 19, address: 24 to 27.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
0
10
00
Set the data.
3
6
01
01
Set the data, and press PAUSE
button.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
6
6
01
01
Set the data, and press PAUSE
button.
7
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
8
6
01
6B
Set the data, and press PAUSE
button.
9
6
01
69
Set the data, and press PAUSE
button.
10
1
Check that the ND display data
(Note1) satisfies the specified
value 3.
11
6
01
6B
Set the data, and press PAUSE
button.
12
1
Check that the ND display data
(Note1) satisfies the specified
value.4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
0
10
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
6-23
DCR-PC350/PC350E
3. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified Value1
40 to C0
Specified Value2
03 to 70
Specified Value3
90 to FD
Note1: Make the lens horizontal and perform this adjustment.
Note2: Perform this adjustment before “Flange Back Adjustment”.
Note3: The data of page: 0, address: 10 must be “00”.
Note4: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
BD
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note5)
4
F
5A
Check that the data satisfies the
specified value 1.
5
F
5B
Check that the data satisfies the
specified value 1.
6
F
5C
Check that the data satisfies the
specified value 1.
7
F
5D
Check that the data satisfies the
specified value 1.
8
F
5E
Check that the data satisfies the
specified value 2.
9
F
5F
Check that the data satisfies the
specified value 3.
10
F
60
Check that the data satisfies the
specified value 2.
11
F
61
Check that the data satisfies the
specified value 3.
12
F
62
Check that the data satisfies the
specified value 2.
13
F
63
Check that the data satisfies the
specified value 3.
14
F
64
Check that the data satisfies the
specified value 2.
15
F
65
Check that the data satisfies the
specified value 3.
Note5: The adjustment data will be automatically input to page: F, address:
58, 5A to 65.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again
6-24
DCR-PC350/PC350E
4. CCD Output 2ch Matching Adjustment (1)
Correct the dispersion of the black level between the left-right
channels of the CCD imager.
Subject
Arbitrary
Adjustment Page
F
19 (Note3)
Adjustment Address
24 to 27
20 to 23, 2A to 2D
Note1: This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”
Note2: After this adjustment, perform the following adjustments.
“CCD Output 2ch Matching Adjustment (2)”,  “Flange Back
Adjustment”, “Color Reproduction Adjustment”
Note3: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note4: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
F3
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note4)
Note3: The adjustment data will be automatically input to page: F, address:
24 to 27 and to page: 19, address: 20 to 23, 2A to 2D.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
Perform “CCD Output 2ch
Matching Adjustment (2)”.
5. CCD Output 2ch Matching Adjustment (2)
Correct the dispersion between the left-right channels of the CCD
imager.
Subject
Clear chart (All white) (Note1)
Adjustment Page
19 (Note2)
Adjustment Address
2E to 3F
Note1: Shoot the clear chart with the zoom TELE end.
Note2: This adjustment should be carried out upon completion of the
following adjustments.
CCD Output 2ch Matching adjustment (1)
Note3: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note4: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
2C
01
Set the data.
4
6
40
01
Set the data.
5
6
01
F5
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01” in about 60 seconds after
pressing PAUSE button.
Note4: The adjustment data will be automatically input to page: 19,
address: 2E to 3F
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
2C
00
Set the data.
4
6
40
00
Set the data.
5
0
01
00
Set the data.
6-25
DCR-PC350/PC350E
6. Flange Back Adjustment (Using Minipattern Box or
Flange Back Adjustment Jig)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Flange back adjustment jig or
minipattern box (Siemens star chart
with ND filter (Note1))
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Specified Value
Data of page: F, address: 57 is “00” to
“09”.
Data of page: 6, address: 0C is “00”.
Note1: Dark Siemens star chart.
Note2: This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”, “MR Adjustment”,
“CCD Output 2ch Matching Adjustment”
Note3: Make the lens horizontal and perform this adjustment.
Note4: The data of page: 0, address: 10 must be “00”.
Note5: Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
COLOR SLOW SHUTTER (CAMERA SET menu) ...... OFF
Preparations for the minipattern box:
1)
The minipattern box is installed as shown in the following
figure.
Note: The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Fig. 6-1-9 (1).
Preparations for the flange back adjustment jig:
1)
Install the flange back adjustment jig so that the distance
between it and the front of the lens of the camcorder is less
than 3cm.
2)
Adjust the illumination intensity to the chart of the flange back
adjustment jig. (350 
±
 50 lux)
3)
Check that at both the zoom TELE end and WIDE end, the
center of the chart and center of the monitor TV screen coincide.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
3
Wait for 2 sec.
4
6
01
27
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note6)
6
6
0C
Check that the data is “00”.
7
F
57
Check that the data is “00” to
“09”.
Note6: The adjustment data will be automatically input to page: F, address:
48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
01
25
Set the data, and press PAUSE
button.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
5
Perform “Flange Back Check”.
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
Preparation of Flange Back Adj.
(Using the flange back adjustment jig)
(Luminance: about 300 lux)
1)
Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2)
Make the height of flange back adjustment jig and the camera
equal.
3)
Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Flange back adjustment jig
Below 3 cm
Camera
Fig. 6-1-9 (2).
Page of 74