DOWNLOAD Sony DCR-PC350 / DCR-PC350E (serv.man4) Service Manual ↓ Size: 1.82 MB | Pages: 74 in PDF or view online for FREE

Model
DCR-PC350 DCR-PC350E (serv.man4)
Pages
74
Size
1.82 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc350-dcr-pc350e-sm4.pdf
Date

Sony DCR-PC350 / DCR-PC350E (serv.man4) Service Manual ▷ View online

6-10
DCR-PC350/PC350E
3. A Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Table. 6-1-2.
4. B Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Initial value
NTSC PAL
00 to 0F
10
11 to 17
18
19 to 2E
2F
30
31
32 to 8F
90
91
92
93
94 to FF
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Touch panel adj.
Fixed data-1
Address
Remark
Initial value
00
D4
15
C4
1F
00
D2
1B
C7
10
Table. 6-1-3.
5. D Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Address
00 to FF
Remark
Fixed data-1
00 to 0F
10 to 13
14
15
16
17 to 28
29
2A
2B
2C
2D
2E
2F
30
31 to 32
33
34 to 44
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Address
Remark
45
46 to 47
48
49
4A
4B
4C
4D
4E
4F
50 to 56
57
58 to 70
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-4.
6. 1A Page Table
Note1: When reading or writing the 1A page data, select page: 0, address:
10, and set data: 01, then select A page. The 1A page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Table. 6-1-5.
7. 1B Page Table
Note1: When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Address
00 to FF
Remark
Fixed data-1
Table. 6-1-6.
Address
00 to FF
Remark
Fixed data-1
6-11
DCR-PC350/PC350E
1-2-2.
INITIALIZATION OF 8, C, 18, 1C PAGE DATA
Note: When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 18, 1C page data, select page: 0, address:
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 18, 1C Page Data
Note1: If “Initializing the 8, C, 18, 1C Page Data” is performed, all data
of the 8 page, C page, 18 page and 1C page will be initialized. (It
is impossible to initialize a single page.)
Note2: If the 8, C, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
18
Adjusting Address
00 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
18, 1C Page Data”.
2. Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 18, 1C page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 18, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
6-12
DCR-PC350/PC350E
3. 8 Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Table. 6-1-6.
00 to 29
2A
2B to 3F
40
41 to 43
44
45 to 79
7A
7B to 83
84
85
86
87
88
89
8A to 94
95
96 to AB
AC
AD to B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC to BD
BE
BF
C0 to C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE to D6
D7
D8 to DF
E0
E1
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Address
Remark
E2
E3
E4
E5
E6
E7
E8 to EF
F0
F1 to F9
FA
FB
FC to FF
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
6-13
DCR-PC350/PC350E
4. C Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Initial value
NTSC PAL
00 to 0F
10
11
12
13
14 to 15
16
17 to 24
25
26
27
28 to 3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49 to 4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B to 5F
60
61
62
63
64 to 65
66
67
68
69 to 6A
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
VCO adj. (EVF)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
VCO adj. (LCD)
V COM adj. (LCD)
Fixed data-2
Fixed data-1
Fixed data-2
Transmissive mode white balance
adj. (LCD)
Contrast adj. (LCD)
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Address
Remark
Initial value
EE
00
00
00
E0
5D
7D
59
8A
80
8D
8F
32
80
76
BC
7B
70
52
EE
00
00
00
E0
5D
7D
59
80
8A
8E
8C
35
78
82
BC
73
6F
51
Initial value
NTSC PAL
Address
Remark
Initial value
6B
6C to 74
75
76 to 78
79
7A
7B
7C
7D
7E
7F to A3
A4
A5 to A6
A7
A8
A9
AA
AB
AC
AD
AE to AF
B0
B1
B2
B3
B4
B5
B6 to CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6 to D7
D8
D9
DA
DB
DC to DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8 to F3
8C
86
08
00
46
01
02
00
00
00
97
8C
08
00
46
01
02
00
00
00
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Reflective mode white balance adj.
(LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Serial No. input
Fixed data-1
Page of 74
Display

Click on the first or last page to see other DCR-PC350 / DCR-PC350E (serv.man4) service manuals if exist.