Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc350-dcr-pc350e-sm4.pdf
Date

Sony DCR-PC350 / DCR-PC350E (serv.man4) Service Manual ▷ View online

6-18
DCR-PC350/PC350E
5. 14 Page Table
Note1: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”).
Table. 6-1-12.
00 to 2B
2C
2D
2E
2F
30
31
32
33
34
35
36 to 3F
40
41
42
43
44
45
46
47
48 to 97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
00
00
00
00
00
00
00
00
EE
F5
45
2F
FE
FF
44
39
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Mixed color compensation adj.
Color reproduction adj.
Mixed color compensation adj.
Initial value
NTSC PAL
Address
Remark
Initial value
00
00
00
00
00
00
00
00
EE
F5
45
2F
FE
FF
44
39
00
00
00
00
00
00
00
00
00
00
B2
B3
B4
B5
B6
B7
B8 to BF
C0
C1
C2
C3
C4
C5
C6
C7
C8 to D1
D2
D3 to D4
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF to E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
00
00
00
00
00
00
1A
00
07
00
1A
00
07
00
1A
00
07
00
11
00
0A
00
11
00
0A
00
11
00
0A
00
Mixed color compensation adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
AWB standard data input
Auto white balance adj.
00
00
00
00
00
00
1A
00
07
00
1A
00
07
00
1A
00
07
00
11
00
0A
00
11
00
0A
00
11
00
0A
00
Initial value
NTSC PAL
Address
Remark
Initial value
6-19
DCR-PC350/PC350E
6. 19 Page Table
Note1: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”).
00 to 05
06
07 to 1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40 to 47
48
49
4A
4B
4C
4D
4E to 53
00
00
00
00
28
D8
28
D8
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
CCD Output 2ch Matching adj. (1)
HALL adj.
ND ON/OFF adj.
Fixed data-1
CCD Output 2ch Matching adj. (1)
CCD Output 2ch Matching adj. (2)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Initial value
NTSC PAL
Address
Remark
Initial value
00
00
00
00
28
D8
28
D8
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Table. 6-1-13.
54
55
56
57
58
59
5A to 5F
60
61
62
63
64
65
66 to 67
68
69
6A to 76
77
78
79 to 86
87
88
89
8A
8B to F5
F6
F7
F8
F9
FA
FB to FF
00
00
00
00
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Emergency memory address
(Camera section)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
00
00
00
00
Initial value
NTSC PAL
Address
Remark
Initial value
6-20
DCR-PC350/PC350E
7. 1E Page Table
Note1: When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”).
8. 1F Page Table
Note1: When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”)
Address
00 to 17
18
19
1A
1B
1C
1D
1E
1F to AC
AD
AE to C8
C9
CA to D0
D1
D2
D3
D4
D5
D6 to D9
DA
DB
DC
DD to DF
E0
E1
E2
E3
E4 to F0
F1
F2
F3
F4 to FF
Remark
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Address
00 to 39
3A
3B to 69
6A
6B to 8D
8E
8F to 95
96
97
98 to AB
AC
AD
AE
AF
B0 to B8
B9
BA
BB to C9
CA
CB
CC
CD
CE to D1
D2
D3 to D9
DA
DB to E4
E5
E6 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-14.
Table. 6-1-15.
6-21
DCR-PC350/PC350E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for “54MHz/
67.5MHz Origin Oscillation Adjustment”), check that the specified
values of “VIDEO SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. 54MHz/67.5MHz Origin Oscillation Adjustment
(CD-537 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Note1: 54MHz .............. DCR-PC350E (PAL)
67.5MHz ........... DCR-PC350 (NTSC)
Subject
Not required
Measurement Point
Pin <zzb> of IC1601 on VC-370 board
(R1606)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
f = 13500000 
±
 68Hz
Note2: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
Fig. 6-1-8.
IC1601
VC-370 board (SIDE A)
Page of 74
Display