DOWNLOAD Sony DCR-PC350 / DCR-PC350E (serv.man4) Service Manual ↓ Size: 1.82 MB | Pages: 74 in PDF or view online for FREE

Model
DCR-PC350 DCR-PC350E (serv.man4)
Pages
74
Size
1.82 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc350-dcr-pc350e-sm4.pdf
Date

Sony DCR-PC350 / DCR-PC350E (serv.man4) Service Manual ▷ View online

6-30
DCR-PC350/PC350E
11. ND ON/OFF Adjustment
Adjustment to reduce the difference in the amount of light when
the ND filter is on and when the ND filter is off.
Subject
Clear chart (All white frame with
zoom WIDE end)  (Note1)
(0.4m (PTB-450) or 0.16m (PTB-
1450) from the front of the lens)
Adjustment Page
19 (Note2)
Adjustment Address
28
Note1: Shoot the clear chart with the zoom WIDE end. And adjust the
direction of the camera so that the chart is located in the center of
the screen.
Note2: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... WIDE end
4)
FOCUS .................................................................. MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
65
AE
Set the data.
4
6
C9
10
Set the data.
5
F
A1
Memorize the data.
6
F
A1
C0
Set the data.
7
6
01
71
Set the data, and press PAUSE
button.
8
6
02
Check that the data changes to
“01”. (Note4)
Note4: The adjustment data will be automatically input to page: 19,
address: 28.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
F
A1
Set the memorized data, and
press PAUSE button.
3
6
65
00
Set the data.
4
6
C9
00
Set the data.
5
6
01
00
Set the data, and press PAUSE
button.
6
0
01
00
Set the data.
12. Picture Frame Setting (All White Frame)
When performing “Auto White Balance Standard Data Input”, “LV
Standard Data Input”, “Auto White Balance Adjustment” and “White
Balance Check”, set the picture frame to “All white frame”.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
TV monitor (Under scan mode)
Specified Value
Whole of the screen is white
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Setting method:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
90
70
Set the data.
3
6
91
02
Set the data.
4
6
92
00
Set the data.
5
6
93
46
Set the data.
6
6
01
79
Set the data, and press PAUSE
button.
7
Check that the whole of the
screen is white.
8
Perform the following
adjustments.
How to release the picture frame setting:
After completing “Auto White Balance Standard Data Input”, “LV
Standard Data Input”, “Auto White Balance Adjustment” and “White
Balance Check”, release the data setting.
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
90
00
Set the data.
4
6
91
00
Set the data.
5
6
92
00
Set the data.
6
6
93
00
Set the data.
6-31
DCR-PC350/PC350E
13. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note4)
Adjustment Page
F
14 (Note2)
Adjustment Address
2E to 31
E8 to F3
Note1: This adjustment should be carried out upon completion of “ND
ON/OFF Adjustment”.
Note2: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform  “12. Picture Frame Setting (All White Frame)” before
this adjustment.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not,
perform “12. Picture Frame
Setting (All White Frame)”.
2
0
01
01
Set the data.
3
0
10
00
Set the data.
4
Wait for more than 2 sec.
5
6
01
43
Set the data, and press PAUSE
button.
6
6
01
41
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
2E to 31 and to page: 14, address: E8 to F3
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
Perform “LV Standard Data
Input”.
5
If finish the camera system
adjustments, perform “How to
release the picture frame setting”
of “12. Picture Frame Setting
(All White Frame)”.
14. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note4)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform  “12. Picture Frame Setting (All White Frame)” before
this adjustment.
Note5: Displayed data of the adjustment remote commander.
1 : XX : XX
     Display data
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not,
perform “12. Picture Frame
Setting (All White Frame)”.
2
0
01
01
Set the data.
3
6
C9
10
Set the data.
4
Wait for more than 6 sec.
5
6
01
0D
Set the data, and press PAUSE button.
6
6
02
Check that the data changes to
“01” within 20 sec. (Note6)
7
0
03
1E
Set the data.
8
1
Check that the display data (Note5)
satisfies the specified value.
Note6: The adjustment data will be automatically input to page: F, address:
1A, 1B.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE button.
2
6
C9
00
Set the data.
3
0
03
00
Set the data.
4
0
01
00
Set the data.
5
Perform “Auto White Balance
Adjustment”.
6
If finish the camera system
adjustments, perform “How to
release the picture frame setting”
of “12. Picture Frame Setting
(All White Frame)”.
6-32
DCR-PC350/PC350E
15. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note3)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
14 (Note2)
Adjustment Address
32 to 35, 44 to 47
F4 to FF
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Perform  “12. Picture Frame Setting (All White Frame)” before
this adjustment.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
Check that the picture frame is
“All white frame”. If not,
perform “12. Picture Frame
Setting (All White Frame)”.
3
0
01
01
Set the data.
4
Wait for more than 2 sec.
5
0
10
00
Set the data.
6
F
44
2D
Set the data, and press PAUSE
button.
7
F
45
20
Set the data, and press PAUSE
button.
8
F
46
5A
Set the data, and press PAUSE
button.
9
F
47
80
Set the data, and press PAUSE
button.
10
6
01
47
Set the data, and press PAUSE
button.
11
6
01
45
Set the data, and press PAUSE
button.
12
6
02
Check that the data changes to
“01”. (Note4)
Note4: The adjustment data will be automatically input to page: F, address:
32 to 35, 44 to 47 and to page: 14, address: F4 to FF
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
Remove the C14 filter.
5
If finish the camera system
adjustments, perform “How to
release the picture frame setting”
of “12. Picture Frame Setting
(All White Frame)”.
6-33
DCR-PC350/PC350E
16. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Adjustment Page
14 (Note1)
Adjustment Address
A0 to A7
Note1: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Picture frame setting:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
1F
10
Set the data.
3
6
90
XL
Set the data. (Note2)
4
6
91
XH
Set the data. (Note2)
5
6
92
YL
Set the data. (Note2)
6
6
93
YH
Set the data. (Note2)
7
6
01
79
Set the data, and press PAUSE
button.
8
Check that the picture frame
becomes “Color reproduction
adjustment frame”.
(Refer to “9. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”.)
Note2: XL, XH, YL and YH are the data read in the “9. Picture Frame
Setting (Color Reproduction Adjustment Frame)”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
1F
10
Set the data.
4
6
C9
10
Set the data.
5
6
9E
00
Set the data.
6
6
9D
31
Set the data.
7
6
01
61
Set the data, and press PAUSE
button.
8
6
02
Check that the data is “01”.
(Note3)
Note3: The adjustment data will be automatically input to page: 14,
address: A0 to A7
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
01
00
Set the data.
2
0
10
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
6
9D
00
Set the data.
5
6
C9
00
Set the data.
6
Perform “Color Reproduction
Check”.
Page of 74