6-46
DCR-PC1000/PC1000E
27. Strobe White Balance Adjustment & Check
Adjust and check the white balance when the strobe light flashes.
Subject
Paper which reflection rate is 18%
(50cm from the front of the lens)(Note1)
Measurement Point
Display data of page 1 (Note7)
Measuring Instrument
Adjustment remote commander
Adjustment Page
6F (Note5)
Adjustment Address
F8, F9
Specified Value
bit15 is “1”
Note1: Background paper (J-2501-130-A). Perform this adjustment in the
dark room or use the flash adjustment box. (Refer to “1-1-
3.Precaution”.)
Note2: Any light other than the strobe light should not light up the paper.
Note3: This adjustment should be carried out upon completion of “HALL
Adjustment”, “Flange Back Adjustment”, “Auto White Balance
Adjustment” and “Strobe Light Level Adjustment”
Note4: After the power is turned on, this adjustment can be done only
once.
Note5: When reading or writing the 6F page data, select page: 0, address:
10, and set data: 06, then select F page. The 6F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note6: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note7: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
WIDE SELECT ................................................................. 4:3
3)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
01
7E
Set the data.
4
7
04
01
Set the data.
5
7
00
01
Set the data, and press PAUSE
button.
6
6
9C
01
Set the data.
7
6
65
AE
Set the data.
8
6
C9
10
Set the data.
9
6
01
B9
Set the data, and press PAUSE
button.
10
Check the flashing.
11
6
02
Check that the data is “01”.
(Note8)
12
6
01
00
Set the data, and press PAUSE
button.
13
Wait for 3 sec.
14
6
01
E7
Set the data, and press PAUSE
button.
15
Check the flashing.
16
0
03
33
Set the data.
17
1
Check that bit15 of the display
data (Note7) is “1”. (Note9)
Note8: The adjustment data will be automatically input to page: F, address:
F8, F9.
Note9: When bit15 of the display data is “1”, the display data is “8000”
to “FFF0”.
If the specified value is not satisfied. Contents of the error are
displayed at the lower digit (bit0 to bit3) of the display data. (For
the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”.)
bit0=1: The white balance is deviated in the blue direction
bit1=1: The white balance is deviated in the yellow direction
bit2=1: The white balance is deviated in the red direction
bit3=1: The white balance is deviated in the cyan direction
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
7
01
7E
Set the data.
4
7
04
00
Set the data.
5
7
00
01
Set the data, and press PAUSE
button.
6
6
65
00
Set the data.
7
6
9C
00
Set the data.
8
6
C9
00
Set the data.
9
0
01
00
Set the data.
6-47
DCR-PC1000/PC1000E
1-4.
COLOR ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENT
Note1: When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2: Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3: As the PANEL OPEN switch is attached to the cabinet (R), this
cabinet must be attached when performing adjustments.
If you perform the adjustments with cabinet (R) removed, set the
following data.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
Note4: NTSC model : DCR-PC1000
PAL model
: DCR-PC1000E
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
LCD panel .................................................................... Closed
3)
WIDE SELECT ................................................................. 4:3
1. EVF Automatic Adjustment (VC-398 board)
This adjustment does the following adjustment items automatically.
VCO adjustment
Contrast adjustment
Mode
CAMERA-TAPE
Signal
Arbitrary
Adjustment Page
C
Adjustment Address
3F, 40 (VCO adj.)
47 (Contrast adj.)
Note1: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
71
00
Set the data, and press PAUSE
button.
3
3
01
5A
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note2)
6
C
3F
Read the data, and this data is
named D
3F
.
7
Convert D
3F
 to decimal notation,
and obtain D
3F
’. (Note3)
8
Calculate D
40
’ using following
equations (Decimal calculation)
[NTSC model]
When D
3F
’   245
D
40
’ = D
3F
’+10
When D
3F
’ > 245
D
40
’ = 255
[PAL model]
When D
3F
’   10
D
40
’ = D
3F
’– 10
When D
3F
’ < 10
D
40
’ = 0
9
Convert D
40
’ to a hexadecimal
number, and obtain D
40
. (Note3)
10
C
40
D
40
Set the data, and press PAUSE
button.
11
C
71
41
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
Note2: If the data is “01”, adjustment has errors. Contents of the error is
written into page: 3, addresses: C6. See the following table.
Note3: Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
Data of page: 3,
address: C6
5E
61
Contents of error
VCO adjustment error
Contrast adjustment error
6-48
DCR-PC1000/PC1000E
2. White Balance Adjustment (VC-398 board)
Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
CAMERA-TAPE
Signal
Arbitrary
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
45, 46
Specified Value
The EVF screen should not be colored.
Note1: Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC7001
Note2: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
45
80
Set the data, and press PAUSE
button.
3
C
46
80
Set the data, and press PAUSE
button.
4
C
46
Check that the EVF screen is not
colored. If not colored, proceed to
step 10.
5
C
45
Change the data so that the EVF
screen is not colored.
6
C
45
Press PAUSE button.
7
C
46
Change the data so that the EVF
screen is not colored.
8
C
46
Press PAUSE button.
9
C
46
If the EVF screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
6-49
DCR-PC1000/PC1000E
1-5.
LCD SYSTEM ADJUSTMENT
Note1: When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2: The LCD system adjustments should be carried out upon
completion of “3-4. VIDEO SYSTEM ADJUSTMENTS”.
Note3: Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note4: If you perform the adjustments with the PANEL OPEN/CLOSE
switch removed, set the following data.
1) Select page: 3, address: C4, and set data: 65.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
Note5: NTSC model : DCR-PC1000
PAL model
: DCR-PC1000E
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
(Except for “Touch Panel Adjustment”.)
2)
LCD panel ...................................................................... Open
3)
WIDE SELECT ............................................................... 16:9
1. LCD Automatic Adjustment (PD-252 board)
This adjustment does the following adjustment items automatically.
VCO adjustment
Contrast adjustment
Mode
CAMERA-TAPE
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
50, 51 (VCO adj.)
58 (Contrast adj.)
Note1: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
70
00
Set the data, and press PAUSE
button.
3
3
01
5A
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note2)
6
C
50
Read the data, and this data is
named D
50
.
7
Convert D
50
 to decimal notation,
and obtain D
50
’. (Note3)
8
Calculate D
51
’ using following
equations (Decimal calculation)
[NTSC model]
When D
50
’   245
D
51
’ = D
50
’ + 10
When D
50
’ > 245
D
51
’ = 255
[PAL model]
When D
50
’   10
D
51
’ = D
50
’ – 10
When D
50
’ < 10
D
51
’ = 0
9
Convert D
51
’ to a hexadecimal
number, and obtain D
51
. (Note3)
10
C
51
D
51
Set the data, and press PAUSE
button.
11
C
70
41
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
Note2: If the data is “01”, adjustment has errors. Contents of the error is
written into page: 3, addresses: C6. See the following table.
Note3: Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
Data of page: 3,
address: C6
58
60
Contents of error
VCO adjustment error
Contrast adjustment error
Page of 79
Display