6-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
6F (Note2)
Adjustment Address
48 to 58
Note1: Make the lens horizontal and perform this adjustment.
Note2: When reading or writing the 6F page data, select page: 0, address:
10, and set data: 06, then select F page. The 6F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE SELECT ................................................................. 4:3
4)
COLOR SLOW SHUTTER (CAMERA SET menu) ...... OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
4D
40
Set the data.
4
6
64
04
Set the data.
5
6
01
13
Set the data, and press PAUSE
button. (Note2)
6
Wait for 2 sec.
7
Place a ND filter on the lens so
that the optimum image is obtain.
8
6
01
29
Set the data, and press PAUSE
button.
9
6
02
Check that the data changes to
“01”. (Note4)
Note4: The adjustment data will be automatically input to page: 6F,
address: 48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
01
25
Set the data, and press PAUSE
button.
4
6
01
00
Set the data, and press PAUSE
button.
5
6
4D
00
Set the data.
6
6
64
00
Set the data.
7
0
01
00
Set the data.
8
Perform “Flange Back Check”
7. Flange Back Check
7-1. Flange Back Check (Using Flange Back
Adjustment Jig)
Subject
Flange back adjustment jig
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE
end.
Note: The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE SELECT ................................................................. 4:3
Preparations:
1)
Install the flange back adjustment jig so that the distance
between it and the front of the lens of the camcorder is less
than 3cm.
2)
To open the IRIS, decrease the luminous intensity to the chart
of the flange back adjustment jig up to a point before noise
appear on the image. (Approx. 200 lux)
3)
Check that at both the zoom TELE end and WIDE end, the
center of the chart and center of the monitor TV screen coincide.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
Set the data.
2
6
41
01
Set the data.
3
6
4D
40
Set the data.
4
6
64
04
Set the data.
5
Shoot the chart with the zoom
TELE end.
6
6
2C
02
Set the data.
7
Check that the lens is focused.
8
Shoot the chart with the zoom
WIDE end.
9
Check that the lens is focused.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
2C
00
Set the data.
2
6
40
00
Set the data.
3
6
41
00
Set the data.
4
6
4D
00
Set the data.
5
6
64
00
Set the data.
6
Reset the WIDE SELECT
switch to “16:9”.
6-31
DCR-PC1000/PC1000E
7-2. Flange Back Check (Using Siemens Star)
Subject
Siemens star
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE
end.
Note1: The data of page: 0, address: 10 must be “00”.
Note2: When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE SELECT ................................................................. 4:3
Preparations:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
(Approx. 200 lux)
Checking method:
Order Page Address Data
Procedure
1
6
40
01
Set the data.
2
6
41
01
Set the data.
3
6
4D
40
Set the data.
4
6
64
04
Set the data.
5
Shoot the chart with the zoom
TELE end.
6
Turn on the auto focus.
7
Check that the lens is focused.
(Note2).
8
6
21
10
Set the data.
9
Shoot the chart with the zoom
WIDE end.
10
Check that the lens is focused.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
21
00
Set the data.
2
6
40
00
Set the data.
3
6
41
00
Set the data.
4
6
4D
00
Set the data.
5
6
64
00
Set the data.
6
0
03
00
Set the data.
7
Reset the WIDE SELECT switch
to “16:9”.
8. Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed for every
F number, and compensate the exposure.
Adjustment Page
6F (Note1)
Adjustment Address
76 to 8B
Note1: When reading or writing the 6F page data, select page: 0, address:
10, and set data: 06, then select F page. The 6F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: NTSC model : DCR-PC1000
PAL model
: DCR-PC1000E
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 0, address: 10, and set data: 06.
3)
Input the following data to page: F, addresses: 76 to 8B.
Note: Press the PAUSE button each time to set the data.
4)
Select page: 0, address: 01, and set data: 00.
5)
Select page: 0, address: 10, and set data: 00.
PAL
48
80
34
80
2A
80
22
80
1B
80
50
57
51
47
33
1F
80
80
80
80
80
80
Address
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
NTSC
55
88
3D
8B
31
87
29
7C
1F
7C
52
5B
56
4E
37
1F
80
80
80
80
80
80
Data
6-32
DCR-PC1000/PC1000E
9. Picture Frame Setting
(Color Reproduction Adjustment Frame)
When performing “Color Reproduction Adjustment” and “PCGM
Standard Data Input”, set the picture frame to “Color reproduction
adjustment frame”.
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO
jack
Measuring Instrument
Oscilloscope,
TV monitor (Under scan mode)
Specified Value
A=B, C=D, E=F
Note1: This adjustment should be carried out upon completion of “HALL
Adjustment” and “Flange Back Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Displayed data of the adjustment remote commander.
1 : XX : XX
XL or YL data
XH or YH data
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE SELECT ................................................................  4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Setting method:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
4D
40
Set the data.
3
Adjust the zoom and the camera
direction, and set to the specified
position.
4
Mark the position of the picture
frame on the monitor display,
and adjust the picture frame to
this position in following
adjustments using “Color
reproduction adjustment frame”.
5
0
03
18
Set the data.
6
1
Read XH data and XL data.
(Note3)
7
0
03
22
Set the data.
8
1
Read YH data and YL data.
(Note3)
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
90
XL
Set the data. (Note4)
3
6
91
XH
Set the data. (Note4)
4
6
92
YL
Set the data. (Note4)
5
6
93
YH
Set the data. (Note4)
6
6
01
79
Set the data, and press PAUSE
button.
Note4: XL, XH, YL and YH are the data read in the “Setting method”.
Note5: This picture frame setting can be released in the following method.
How to release the picture frame setting:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
4D
00
Set the data.
4
6
90
00
Set the data.
5
6
91
00
Set the data.
6
6
92
00
Set the data.
7
6
93
00
Set the data.
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-11.
2. Vertical period
Fig. 6-1-12.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-13.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
6-33
DCR-PC1000/PC1000E
10. Picture Frame Setting (All White Frame)
When performing “Auto White Balance Standard Data Input”, “LV
Standard Data Input”, “Auto White Balance Adjustment” and “White
Balance Check”, set the picture frame to “All white frame”.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO
jack
Measuring Instrument
TV monitor (Under scan mode)
Specified Value
Whole of the screen is white
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE SELECT ................................................................. 4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Setting method:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
4D
40
Set the data.
3
6
90
70
Set the data.
4
6
91
02
Set the data.
5
6
92
00
Set the data.
6
6
93
46
Set the data.
7
6
01
79
Set the data, and press PAUSE
button.
8
Check that the whole of the screen
is white.
9
Perform the following
adjustments.
Processing after Completing Adjustments
After completing “Auto White Balance Standard Data Input”, “LV
Standard Data Input”, “Auto White Balance Adjustment” and “White
Balance Check”, release the data setting.
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
4D
00
Set the data.
4
6
90
00
Set the data.
5
6
91
00
Set the data.
6
6
92
00
Set the data.
7
6
93
00
Set the data.
8
Reset the WIDE SELECT switch
to “16:9”.
11. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note4)
Adjustment Page
6E (Note2)
Adjustment Address
00 to 0F
Note1: This adjustment should be carried out upon completion of “Picture
Frame Setting (All White Frame)”.
Note2: When reading or writing the 6E page data, select page: 0, address:
10, and set data: 06, then select E page. The 6E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform  “10. Picture Frame Setting (All White Frame)” before
this adjustment.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE SELECT ................................................................. 4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not, perform
“10. Picture Frame Setting (All
White Frame)”.
2
0
01
01
Set the data.
3
0
10
00
Set the data.
4
6
4D
40
Set the data.
5
Wait for more than 2 sec.
6
6
01
43
Set the data, and press PAUSE
button.
7
6
01
41
Set the data, and press PAUSE
button.
8
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: 6E,
address: 00 to 0F.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
Perform “LV Standard Data
Input”.
5
If finishing the camera system
adjustments, perform “Processing
after Completing Adjustments” of
“10. Picture Frame Setting (All
White Frame)”.
Page of 79
Display

Click on the first or last page to see other DCR-PC1000 / DCR-PC1000E (serv.man4) service manuals if exist.