DOWNLOAD Sony DCR-PC1000 / DCR-PC1000E (serv.man4) Service Manual ↓ Size: 1.12 MB | Pages: 79 in PDF or view online for FREE

Model
DCR-PC1000 DCR-PC1000E (serv.man4)
Pages
79
Size
1.12 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc1000-dcr-pc1000e-sm4.pdf
Date

Sony DCR-PC1000 / DCR-PC1000E (serv.man4) Service Manual ▷ View online

6-14
DCR-PC1000/PC1000E
Initial value
NTSC PAL
Address
Remark
Initial value
48
49 to 4B
4C
4D
4E
4F
50
51
52
53 to 54
55
56
57
58
59 to 5E
5F
60 to 61
62
63
64 TO 65
66
67
68
69 to 6A
6B
6C to 74
75
76 to 78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B to 90
91
92
93
94
95
96
97 to 98
99
9A to A0
6C
90
B8
80
80
52
9A
95
91
BA
85
00
00
00
00
33
D2
A8
23
80
78
80
B8
80
80
52
9A
95
8C
CD
92
00
00
00
00
33
D2
A8
23
80
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
VCO adj. (LCD)
V COM adj. (LCD)
Fixed data-1
Fixed data-2
Transmissive mode white balance
adj. (LCD)
Contrast adj. (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Reflective mode white balance adj.
(LCD)
Fixed data-1
Fixed data-2
Fixed data-1
IC4701 LINE OUT Y level adj.
IC4701 LINE OUT chroma level adj.
IC4701 automatic adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
IC4701 automatic adj.
Fixed data-1
A1
A2
A3
A4
A5 to A6
A7
A8
A9
AA
AB
AC
AD
AE to AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB to CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
D7 to DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8 to F3
F4
F5
F6
F7
F8
F9
FA
FB
1F
1F
1F
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
19
19
19
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
IC4701 automatic adj.
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Serial No. input
Fixed data-1
Emergency memory address
(Mechanism section)
Initial value
NTSC PAL
Address
Remark
Initial value
C page
6-15
DCR-PC1000/PC1000E
Table. 6-1-8.
5. 18 Page Table
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Initial value
NTSC PAL
Address
Remark
Initial value
FC
FD
FE
FF
00
00
00
00
00
00
00
00
Emergency memory address
(Mechanism section)
Table. 6-1-9.
6. 1C Page Table
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Note3: When checking the 3 page data, the data of page: 0, address: 10
must be “00”.
C page
Address
00
01
02 to D7
D8
D9 to DC
DD
DE
DF
E0
E1 to E3
E4
E5 to F1
F2
F3 to F6
F7
F8 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-10.
Address
Remark
Initial value
00 to 77
78
79 to A9
AA
AB to B2
B3
B4
B5
B6
B7
B8
00
00
00
00
00
80
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Error rate check
Address
Remark
Initial value
Address
Remark
Initial value
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9 to D4
D5
D6 to E5
E6
E7
E8
E9
EA
EB
EC
ED to EE
EF
F0
F1 to F3
F4
F5
F6
F7
F8
F9
FA to FF
00
00
00
00
00
00
00
00
00
00
80
00
00
00
00
00
Error rate check
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2 (Modified data. Copy
the data built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
6-16
DCR-PC1000/PC1000E
1-2-3.
INITIALIZATION OF 63 to 6F PAGE DATA
Note: When reading or writing the 63 to 6F page data, select page: 0,
address: 10, and set data: 06, then select 3, 4, 5, 6, 7, 8, 9, A, B, C,
D, E, or F page. The 63, 64, 65, 66, 67, 68, 69, 6A, 6B, 6C, 6D, 6E,
or 6F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 63 to 6F Page Data
Note1: If “Initializing the 63 to 6F Page Data” is performed, all data of
the 63 to 6F pages will be initialized. (It is impossible to initialize
a single page.)
Note2: If the 63 to 6F page data has been initialized, following adjustments
need to be performed again.
1) Modification of 63 to 6F page data
2) Camera system adjustments
Adjusting page
63
Adjusting Address
00 to FF
Adjusting page
64
Adjusting Address
00 to FF
Adjusting page
65
Adjusting Address
00 to FF
Adjusting page
66
Adjusting Address
00 to FF
Adjusting page
67
Adjusting Address
00 to FF
Adjusting page
68
Adjusting Address
00 to FF
Adjusting page
69
Adjusting Address
00 to FF
Adjusting page
6A
Adjusting Address
00 to FF
Adjusting page
6B
Adjusting Address
00 to FF
Adjusting page
6C
Adjusting Address
00 to FF
Adjusting page
6D
Adjusting Address
00 to FF
Adjusting page
6E
Adjusting Address
00 to FF
Adjusting page
6F
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D: DCR-PC1000 (NTSC)
2F: DCR-PC1000E (PAL)
4
6
03
01
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
6
01
00
Set the data, and press PAUSE
button.
7
Perform “Modification of 63 to
6F Page Data”.
2. Modification of 63 to 6F Page Data
If the 63 to 6F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 63 to 6F page data, select page: 0, address:
10, and set data: 06.
After completing the modification of 63 to 6F page data, reset
the data of this address to “00”.
3)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
4)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 63 to 6F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
3. 63 Page Table
Note1: When reading or writing the 63 page data, select page: 0, address:
10, and set data: 06, then select 3 page. The 63 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 63 to
6F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 63 to
6F Page Data”.)
Address
00 to 4D
4E
4F to 55
56
58 to 65
66
67 to 75
76
77 to 7D
7E
7F to 81
82
83
84
85
86
87 to 89
8A
8B to 8E
8F
90 to 91
92
93 to 95
96
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
6-17
DCR-PC1000/PC1000E
Table. 6-1-11.
4. 64 Page Table
Note1: When reading or writing the 64 page data, select page: 0, address:
10, and set data: 06, then select 4 page. The 64 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 63 to
6F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 63 to
6F Page Data”.)
Table. 6-1-12.
Address
Remark
97 to 99
9A
9B to 9D
9E
9F to A1
A2
A3 to A5
A6
A7 to A8
A9
AA to AE
AF
B0
B1
B2 to B6
B7
B8
B9
BA to BE
BF
C0
C1
C2 to C6
C7
C8
C9
CA to CE
CF
D0
D1
D2 to D6
D7
D8
D9
DA to F6
F7
F8 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
00 to 0F
10
11
12 to 1F
20
21
22
23
24
25
26
27
28 to 3F
40
41
42
43 to 49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62 to DD
DE
DF
E0 to E7
E8
E9 to FD
FE
FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
63 page
Page of 79
Display