DOWNLOAD Sony DCR-PC1000 / DCR-PC1000E (serv.man4) Service Manual ↓ Size: 1.12 MB | Pages: 79 in PDF or view online for FREE

Model
DCR-PC1000 DCR-PC1000E (serv.man4)
Pages
79
Size
1.12 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc1000-dcr-pc1000e-sm4.pdf
Date

Sony DCR-PC1000 / DCR-PC1000E (serv.man4) Service Manual ▷ View online

6-6
DCR-PC1000/PC1000E
Fig. 6-1-3.
7
5
3
2
6
4
1
Adjustment remote
commander (RM-95)
AC power
adaptor 
AC IN
For tape path adjustment
1
 RF MON
2
 SWP
3
 GND
4
 XSC EEP (
*2
)
5
 EEP SCK (
*2
)
6
 EEP SO (
*2
)
7
 EEP SI (
*2
)
I/F unit for LANC control
(J-6082-521-A)
*1
*1
*1: Don’t connect any cable 
to these connectors.
*2 : 
Not used.
[CONNECTION OF EQUIPMENT]
1
 
Open the jack cover.
2
 
Open the cassette lid.
3
 
Screw (M1.4 
×
1.5) (Silver)
4
 
CPC lid
CN002
CN001
BATT
LANC
Not used
Not used
Not used
8
1
CPC-15
(J-6082-564-A)
CPC lid
H
H
Screw
M1.4 
×
1.5
3-062-214-01
Silver
Cassette lid
Jack cover
6-7
DCR-PC1000/PC1000E
White
Black
841mm
1189mm
1-1-3.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
1.
POWER switch (PS11800 block) ............... CAMERA-TAPE
2.
NIGHT SHOT switch (Lens block) ................................. OFF
3
WIDE SELECT (SB10600 block) ..................................... 4:3
4.
BACK LIGHT switch (PS11800 block) .......................... OFF
5.
MENU settings (Touch panel)
   CAMERA SET menu
PROGRAM AE .................................................... AUTO
SPOT METER ...................................................... AUTO
EXPOSURE ......................................................... AUTO
WHITE BALANCE ............................................. AUTO
AE SHIFT ..................................................................... 0
FOCUS .......................................................... MANUAL
TELE MACRO ......................................................... OFF
COLOR SLOW SHUTTER ..................................... OFF
ZEBRA ..................................................................... OFF
DIGITAL ZOOM ..................................................... OFF
STEADY SHOT ....................................................... OFF
   PICT. APPLI menu
DIGITAL EFFECT ................................................... OFF
PICTURE EFFECT .................................................. OFF
DEMO MODE ......................................................... OFF
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig. 6-1-4.
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (All white frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. And set data for the all white frame.
3)
Flange back adjustment chart
Make the chart shown in Fig. 6-1-5 using A0 size (1189mm 
×
841mm) black and white vellum paper.
Fig. 6-1-5.
Note: Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Color bar chart (Color reproduction adjustment frame )
Fig. a
(Video output terminal
output waveform)
Fig. b (TV monitor picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a
and the TV monitor display shown in Fig. b.
6-8
DCR-PC1000/PC1000E
4. Preparing the Flash Adjustment Box
A dark room is required to provide an accurate strobe adjustment.
If it is not available, prepare the flash adjustment box as given below;
1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2 sheets)
400 mm
woody board B (2 sheets)
370 mm
woody board C (1 sheet)
700 mm
513 mm
513 mm
700 mm
700 mm
730 mm
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper side
of woody board A, B and C are internal. (Fig. 6-1-7)
Fig. 6-1-6.
woody board A
woody board B
woody board B
woody board C
woody board A
Fig. 6-1-7.
6-9
DCR-PC1000/PC1000E
1-2.
INITIALIZATION OF EEPROM DATA
Note1: Pages used for the EEPROM consists of 22 pages. These are 8, A
to D, 18, 1A to 1C, 63 to 6F pages.
Note2: When reading or writing the 18, 1A to 1C page data, select page:
0, address: 10, and set data: 01, then select 8, A, B, or C page. The
18, 1A, 1B, or 1C page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: When reading or writing the 63 to 6F page data, select page: 0,
address: 10, and set data: 06, then select 3, 4, 5, 6, 7, 8, 9, A, B, C,
D, E, or F page. The 63, 64, 65, 66, 67, 68, 69, 6A, 6B, 6C, 6D,
6E, or 6F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1-2-1.
INITIALIZATION OF A, B, D, 1A, 1B PAGE DATA
Note: When reading or writing the A, B, D page data, select page: 0,
address: 10, and set data: 00.
When reading or writing the 1A or 1B page data, select page: 0,
address: 10, and set data: 01, then select A or B page. The 1A or 1B
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the A, B, D, 1A, 1B Page Data
Note1: If the A, B, D, 1A, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, B, D, 1A, 1B page data
2) Touch panel adjustment
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
D
Adjusting Address
10 to 7F
Adjusting page
1A
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
04
Set the following data.
60 (DCR-PC1000 (NTSC))
61 (DCR-PC1000E (PAL))
4
7
01
XX
Set the data. (Note2)
5
7
00
01
Set the data, and press PAUSE
button. (Note)
6
7
02
Check that the data changes to
“01”
7
Perform “Modification of A, B,
D, 1A, 1B Page Data”.
Note2: XX=20: Initializing A page
XX=21: Initializing B page
XX=22: Initializing D page
XX=23: Initializing 1A page
XX=24: Initializing 1B page
XX=25: Initializing A and 1A page
XX=26: Initializing B and 1B page
XX=28: Initializing A, B, D, 1A and 1B pages
2. Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the A, B, D page data, select page: 0, address:
10, and set data: 00.
3)
When changing the 1A, 1B page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 1A, 1B page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, B, D, 1A, 1B
Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
Note: If the following symptoms occur after completing of the
“Modification of A, B, D, 1A, 1B page data”, check that the data of
addresses: 1A to 4F of A page and the data of addresses: 12 to 19 of
D page are same as those of the same model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
Page of 79
Display