DOWNLOAD Sony DCR-PC1000 / DCR-PC1000E (serv.man4) Service Manual ↓ Size: 1.12 MB | Pages: 79 in PDF or view online for FREE

Model
DCR-PC1000 DCR-PC1000E (serv.man4)
Pages
79
Size
1.12 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc1000-dcr-pc1000e-sm4.pdf
Date

Sony DCR-PC1000 / DCR-PC1000E (serv.man4) Service Manual ▷ View online

6-34
DCR-PC1000/PC1000E
12. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note4)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
6F (Note2)
Adjustment Address
2A, 2B
Specified Value
0FE0 to 1020
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: When reading or writing the 6F page data, select page: 0, address:
10, and set data: 06, then select F page. The 6F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform  “10. Picture Frame Setting (All White Frame)” before
this adjustment.
Note5: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE SELECT ................................................................  4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not, perform
“10. Picture Frame Setting (All
White Frame)”.
2
0
01
01
Set the data.
3
0
10
00
Set the data.
4
6
4D
40
Set the data.
5
6
C9
10
Set the data.
6
Wait for more than 6 sec.
7
6
01
0D
Set the data, and press PAUSE
button.
8
6
02
Check that the data changes to
“01” within 20 sec. (Note6)
9
0
03
1E
Set the data.
10
1
Check that the display data
(Note5) satisfies the specified
value.
Note6: The adjustment data will be automatically input to page: 6F,
address: 2A, 2B.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
C9
00
Set the data.
3
0
03
00
Set the data.
4
0
01
00
Set the data.
5
Perform “Auto White Balance
Adjustment”.
6
If finishing the camera system
adjustments, perform “Processing
after Completing Adjustments” of
“10. Picture Frame Setting (All
White Frame)”.
6-35
DCR-PC1000/PC1000E
13. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note3)
Filter
Filter C14 for color temperature
correction
Adjustment Page
6E (Note2)
6F (Note2)
Adjustment Address
10 to 1F
FC to FF
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: When reading or writing the 6E and 6F page data, select page: 0,
address: 10, and set data: 06, then select E page or F page. The 6E
page or 6F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Perform  “10. Picture Frame Setting (All White Frame)” before
this adjustment.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE SELECT ................................................................. 4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
Check that the picture frame is
“All white frame”. If not, perform
“10. Picture Frame Setting (All
White Frame)”.
3
0
01
01
Set the data.
4
0
10
00
Set the data.
5
6
4D
40
Set the data.
6
Wait for more than 2 sec.
7
0
10
06
Set the data.
8
F
FC
2D
Set the data, and press PAUSE
button. (Note4)
9
F
FD
D0
Set the data, and press PAUSE
button. (Note4)
10
F
FE
5C
Set the data, and press PAUSE
button. (Note4)
11
F
FF
00
Set the data, and press PAUSE
button. (Note4)
12
0
10
00
Set the data.
13
6
01
47
Set the data, and press PAUSE
button.
14
6
01
45
Set the data, and press PAUSE
button.
15
6
02
Check that the data changes to
“01”. (Note5)
Note4: Data setting of 6F page.
Note5: The adjustment data will be automatically input to page: 6E,
address: 10 to 1F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
4D
00
Set the data.
3
6
90
00
Set the data.
4
6
91
00
Set the data.
5
6
92
00
Set the data.
6
6
93
00
Set the data.
7
6
01
00
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
9
Remove the C14 filter.
Note6: If finishing the camera system adjustments, reset the WIDE
SELECT switch to “16:9”.
6-36
DCR-PC1000/PC1000E
14. PCGM Standard Data Input
Adjust the matrix coefficient for compensating the variation in
spectral responsivity, to carry out presumed detection of the light
source for AWB.
Adjustment Page
6F (Note1)
Adjustment Address
2E to 3F
Note1: When reading or writing the 6F page data, select page: 0, address:
10, and set data: 06, then select F page. The 6F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: NTSC model : DCR-PC1000
PAL model
: DCR-PC1000E
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 0, address: 10, and set data: 06.
3)
Input the following data to page: F, addresses: 2E to 3F.
Note: Press the PAUSE button each time to set the data.
4)
Select page: 0, address: 01, and set data: 00.
5)
Select page: 0, address: 10, and set data: 00.
PAL
29
0C
FF
D0
FF
A4
00
DE
1E
BA
01
50
FF
FD
FF
FE
19
C7
Address
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
NTSC
27
5D
FF
52
FF
9C
01
3E
1E
B8
00
87
FF
FC
00
20
1A
F0
Data
Ver 1.1  2005. 09
6-37
DCR-PC1000/PC1000E
15. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Adjustment Page
6E (Note1)
Adjustment Address
20 to 27
Note1: When reading or writing the 6E page data, select page: 0, address:
10, and set data: 06, then select E page. The 6E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE SELECT ................................................................. 4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Picture frame setting:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
1F
10
Set the data.
3
6
4D
40
Set the data.
4
6
90
XL
Set the data. (Note2)
5
6
91
XH
Set the data. (Note2)
6
6
92
YL
Set the data. (Note2)
7
6
93
YH
Set the data. (Note2)
8
6
01
79
Set the data, and press PAUSE
button.
9
Check that the picture frame
becomes “Color reproduction
adjustment frame”.
(Refer to “9. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”.)
Note2: XL, XH, YL and YH are the data read in the “9. Picture Frame
Setting (Color Reproduction Adjustment Frame)”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
1F
10
Set the data.
4
6
4D
40
Set the data.
5
6
C9
10
Set the data.
6
6
9E
00
Set the data.
7
6
9D
27
Set the data.
8
6
01
61
Set the data, and press PAUSE
button.
9
6
02
Check that the data is “01”.
(Note3)
Note3: The adjustment data will be automatically input to page: 6E,
address: 20 to 27.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
01
00
Set the data.
2
0
10
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
6
9D
00
Set the data.
5
6
C9
00
Set the data.
6
Perform “Color Reproduction
Check (Indoor)”.
Page of 79
Display

Click on the first or last page to see other DCR-PC1000 / DCR-PC1000E (serv.man4) service manuals if exist.