Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc1000-dcr-pc1000e-sm4.pdf
Date

Sony DCR-PC1000 / DCR-PC1000E (serv.man4) Service Manual ▷ View online

6-42
DCR-PC1000/PC1000E
21. White Defect Adjustment
Detect the white defective pixels of the CMOS image sensor.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Specified Value
Data of page: 6, address: D3 is “00”.
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Adjustment”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
06
Set the data.
3
B
41
10
Set the data, and press PAUSE
button.
4
0
10
00
Set the data.
5
6
D0
06
Set the data.
6
6
01
21
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”.
8
6
D3
Check that the data is “00”.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
Perform “White Defect Check”.
22. White Defect Check
Check that the white defective pixels are compensated.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Specified Value
Data of page: 6, address: D1 is “00”.
Data of page: 6, address: D2 is “00”
Note1: This adjustment should be carried out upon completion of “White
Defect Adjustment”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
Checking method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
06
Set the data.
3
B
41
40
Set the data, and press PAUSE
button.
4
0
10
00
Set the data.
5
6
D0
04
Set the data.
6
6
01
21
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”.
8
6
D1
Check that the data is “00”.
9
6
D2
Check that the data is “00”.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
D0
00
Set the data.
4
0
10
06
Set the data.
5
B
41
10
Set the data, and press PAUSE
button.
6
0
10
00
Set the data.
7
0
01
00
Set the data.
6-43
DCR-PC1000/PC1000E
23. Black Defect Adjustment
Detect the black defective pixels of the CMOS image sensor.
Subject
Clear chart (All white frame with zoom
TELE end)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
6E (Note2)
Adjustment Address
40 to 5A
Specified Value
Data of page: 6, address: D3 is “00”.
Note1: This adjustment should be carried out upon completion of “White
Defect Adjustment”.
Note2: When reading or writing the 6E page data, select page: 0, address:
10, and set data: 06, then select E page. The 6E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
WIDE SELECT ................................................................. 4:3
3)
FOCUS (CAMERA SET menu) ........................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Turn off the power and turn on
again
2
0
01
01
Set the data.
3
0
10
00
Set the data.
4
6
9C
01
Set the data.
5
6
90
00
Set the data.
6
6
91
04
Set the data.
7
6
92
00
Set the data.
8
6
93
10
Set the data.
9
6
01
79
Set the data, and press PAUSE
button.
10
Check that the whole of the screen
is white.
11
6
D0
01
Set the data.
12
6
01
21
Set the data, and press PAUSE
button.
13
6
02
Check that the data changes to
“01”.
Note4: The adjustment data will be automatically input to page: 6E,
address: 40 to 5A.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
9C
00
Set the data.
4
0
01
00
Set the data.
5
Perform “Black Defect Check”.
24. Black Defect Check
Check that the black defective pixels are compensated.
Subject
Clear chart (All white frame with zoom
TELE end)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point
Adjustment remote commander
Measuring Instrument
Specified Value
Data of page: 6, address: D1 is “00”.
Data of page: 6, address: D2 is “00”
Note1: This adjustment should be carried out upon completion of “Black
Defect Adjustment”.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
WIDE SELECT ................................................................. 4:3
3)
FOCUS (CAMERA SET menu) ........................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
9C
01
Set the data. (Note3)
4
6
90
00
Set the data. (Note3)
5
6
91
04
Set the data. (Note3)
6
6
92
00
Set the data. (Note3)
7
6
93
10
Set the data. (Note3)
8
6
01
79
Set the data, and press PAUSE
button. (Note3)
9
Check that the whole of the screen
is white.
10
0
10
06
Set the data.
11
B
47
07
Set the data, and press PAUSE
button.
12
0
10
00
Set the data.
13
6
D0
03
Set the data.
14
6
01
21
Set the data, and press PAUSE button.
15
6
02
Check that the data changes to “01”.
16
6
D1
Check that the data is “00”.
17
6
D2
Check that the data is “00”.
Note3: When performing this adjustment after “Black Defect Adjustment”,
it is not necessary to carry out Steps 3 to 8.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE button.
3
0
10
06
Set the data.
4
B
47
02
Set the data, and press PAUSE button.
5
0
10
00
Set the data.
6
6
90
00
Set the data.
7
6
91
00
Set the data.
8
6
92
00
Set the data.
9
6
93
00
Set the data.
10
6
D0
00
Set the data.
11
0
01
00
Set the data.
Note4: If finishing the camera system adjustments, reset the WIDE
SELECT switch to “16:9”.
6-44
DCR-PC1000/PC1000E
25. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03MA
Type B: ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2680 to 5080
Note1: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2: The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (CAMERA SET menu) ......................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(FR-229 board SE4001)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value.
Yaw sensor check
(FR-229 board SE4002)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
Move the camcorder, and check
that the steady shot operations
have been performed normally
6-45
DCR-PC1000/PC1000E
26. Strobe Light Level Adjustment
Adjust the light level when the strobe light flashes.
Subject
Paper which reflection rate is 18%
(50cm from the front of the lens)(Note1)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
6F (Note4)
Adjustment Address
8C to 91
Specified Value
Data of page: 6, address: 0C is “00”.
Note1: Background paper (J-2501-130-A). Perform this adjustment in the
dark room or use the flash adjustment box. (Refer to “1-1-
3.Precaution”.)
Note2: Any light other than the strobe light should not light up the paper.
Note3: This adjustment should be carried out upon completion of “HALL
Adjustment”, “Flange Back Adjustment”.
Note4: When reading or writing the 6F page data, select page: 0, address:
10, and set data: 06, then select F page. The 6F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note5: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
WIDE SELECT ................................................................. 4:3
3)
NIGHT SHOT .................................................................. OFF
How to reset the flash error flag
When the flash error self-diagnosis code (E: 91: **) is displayed.
After repair, clear the error flag in the following method.
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
7
01
75
Set the data.
3
7
00
01
Set the data, and press PAUSE
button.
4
7
02
Check that the data is “01”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
01
7E
Set the data.
4
7
04
01
Set the data.
5
7
00
01
Set the data, and press PAUSE
button.
6
6
9C
01
Set the data.
7
6
65
AE
Set the data.
8
6
C9
10
Set the data.
9
6
01
67
Set the data, and press PAUSE
button.
10
Check the flashing.
11
6
02
Check that the data is “01”.
(Note6)
12
6
0C
Check that the data is “00”.
Note6: The adjustment data will be automatically input to page: 6F,
address: 8C to 91.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
7
01
7E
Set the data.
4
7
04
00
Set the data.
5
7
00
01
Set the data, and press PAUSE
button.
6
6
65
00
Set the data.
7
6
C9
00
Set the data.
8
0
01
00
Set the data.