Sony DCR-IP5 / DCR-IP5E / DCR-IP7BT / DCR-IP7E (serv.man3) Service Manual ▷ View online

5-23
DCR-IP5/IP5E/IP7BT/IP7E
12. Picture Frame Setting
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.5m from the front of the lens)
Measurement Point
Video output of A/V jack
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Switch setting:
1)
POWER .................................................................. CAMERA
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Setting method:
1)
Adjust the zoom and the camera direction, and set to the
specified position.
2)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.
Check on the oscilloscope
1. Horizontal period
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
Fig. 5-1-9.
Fig. 5-1-10.
Fig. 5-1-11.
2. Vertical period
Check on the monitor TV (Underscanned mode)
5-24
DCR-IP5/IP5E/IP7BT/IP7E
13. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment frame)
Measurement Point
Video output of A/V jack
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
35, 37, 3C, 3D
Specified Value
All color luminance points should settle
within each color reproduction frame.
Note1:
This adjustment should be carried out upon completion of the LV
standard data input.
Note2:
NTSC model: DCR-IP5/IP7BT
PAL model: DCR-IP5E/IP7E
Switch setting:
1)
POWER .................................................................. CAMERA
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 8E, set data: 29, and press the PAUSE
button.
3)
Select page: F, address: C0, set the following data and press
the PAUSE button.
37: NTSC model
B7: PAL model
4)
Select page: 6, address: 01, set data: 3D, and press the PAUSE
button.
5)
Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
6)
Change the data of page: F, address: 35, 37, 3C and 3D, and
settle each color luminance point in each color reproduction
frame.
Note:
Be sure to press the PAUSE button before changing the
addresses. If not, the new data will not be written to the memory.
Processing after Completing Adjustments:
1)
Select page: F, address: 8E, set data: 2E, and press the PAUSE
button.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
3)
Select page: 0, address: 01, and set data: 00.
Burst position
For NTSC model
Burst position
For PAL model
Fig. 5-1-12.
5-25
DCR-IP5/IP5E/IP7BT/IP7E
14. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
30 to 33
Note1:
After the power is turned on, this adjustment can be done only
once.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
DIGITAL ZOOM (Menu display) ................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
11
Set the data, and press PAUSE
button.
3
6
01
0B
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note3)
Note3:
The adjustment data will be automatically input to page: E, address:
30 to 33.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Perform “Auto White Balance
Adjustment”.
5-26
DCR-IP5/IP5E/IP7BT/IP7E
15. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note3)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
40, 41
Specified Value
DCR-IP5/IP7BT (NTSC):
R ratio: 2C60 to 2D60
B ratio: 5B00 to 5C00
DCR-IP5E/IP7E (PAL):
R ratio: 2C50 to 2D50
B ratio: 59A0 to 5AA0
Note1:
After the power is turned on, this adjustment can be done only
once.
Note2:
Perform “Auto White Balance Standard Data Input” before this
adjustment.
Note3:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
DIGITAL ZOOM (Menu display) ................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
0
01
01
Set the data.
3
F
42
Write down the data.
4
F
42
2C
Set the data, and press PAUSE
button.
5
F
43
Write down the data.
6
F
43
Set the following data, and press
PAUSE button.
E0 (NTSC), D0 (PAL)
7
F
44
Write down the data.
8
F
44
Set the following data, and press
PAUSE button.
5B (NTSC), 5A (PAL)
9
F
45
Write down the data.
10
F
45
Set the following data, and press
PAUSE button.
80 (NTSC), 20 (PAL)
11
6
01
83
Set the data, and press PAUSE
button.
12
6
01
81
Set the data, and press PAUSE
button.
13
6
02
Check that the data changes to
“01”. (Note4)
14
6
01
3F
Set the data, and press PAUSE
button.
15
6
04
04
Set the data.
16
1
Check that the display data (Note3)
satisfies the R ratio specified value.
17
6
04
05
Set the data.
18
1
Check that the display data (Note3)
satisfies the B ratio specified value.
Note4:
The adjustment data will be automatically input to page: F, address:
40, 41.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
04
00
Set the data.
3
F
42
Set the data that is written down
at step 3, and press PAUSE button.
4
F
43
Set the data that is written down
at step 5, and press PAUSE button.
5
F
44
Set the data that is written down
at step 7, and press PAUSE button.
6
F
45
Set the data that is written down
at step 9, and press PAUSE button.
7
0
01
00
Set the data.
Page of 63