5-19
DCR-IP5/IP5E/IP7BT/IP7E
6. Flange Back Check
Subject
Siemens star
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE
end.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Note:
When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 6, address: 04, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Shoot the Siemens star with the zoom TELE end.
4)
Turn on the auto focus.
5)
Check that the lens is focused (Note).
6)
Select page: 6, address: 21, and set data: 10.
7)
Shoot the Siemens star with the zoom WIDE end.
8)
Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 6, address: 04, and set data: 00.
5-20
DCR-IP5/IP5E/IP7BT/IP7E
7. Optical Axis Adjustment
Align the lens optical Axis with that of the CCD imager. If deviated,
center of picture can lose focus when zoom is operated from the
WIDE end to the TELE end.
Subject
Siemens star
Measurement Point
Check on the monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
69
Switch setting:
POWER .................................................................. CAMERA
Preparations before adjustments:
1)
Connect a DV camcorder to the monitor TV.
2)
Playback the monoscope segment of the system check tape
(XH5-5 (NTSC), XH5-5P (PAL)) with the DV camcorder.
3)
Attach the optical axis frame chart (transparent) on the monitor
TV screen. Center of monoscope image and that that of optical
axis frame must be agree.
4)
Disconnect the DV camcorder from the monitor TV.
5)
Connect the MICRO MV camcorder which must be adjusted
to the monitor TV.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 40, and set data: 02.
3)
Select page: 6, address: 41, and set data: 01.
4)
Select page: F, address: 69, set data: 00 and press the PAUSE
button.
5)
Place the Siemens star 2.0 m away from the front of the lens.
6)
Shoot the Siemens star with the zoom TELE end.
7)
Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
8)
Shoot the Siemens star with the zoom WIDE end.
9)
Measure on the monitor TV screen in which area of the optical
axis frame the center of the Siemens star is located. Measure
the amount of displacement (distance between the center of
the Siemens star and the center of the optical axis frame.) The
measurement value is named L1.
10) Read the correction data corresponding to the area from Table
5-1-11.
11) Select page: F, address: 69, set the correction data and press
the PAUSE button.
12) Shoot the Siemens star with the zoom TELE end.
13) Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
14) Shoot the Siemens star with the zoom WIDE end.
15) Measure the amount of displacement (distance between the
center of the Siemens star and the center of the optical axis
frame.) The measurement value is named L2.
16) Compare the values L1 and L2, and confirm that L2 is smaller
than L1. If L2 is lager than L1, select page: F, address: 69 and
set data: 00 and press the PAUSE button.
Table 5-1-11.
Processing after Completing Adjustments:
1)
Select page: 0, address: 01, and set data: 00.
2)
Select page: 6, address: 40, and set data: 00.
3)
Select page: 6, address: 41, and set data: 00.
Area
1
2
3
4
5
6
7
8
Display phase
22.6
°
 to 67.5
°
67.6
°
 to 112.5
°
112.6
°
 to 157.5
°
157.6
°
 to 202.5
°
202.6
°
 to 247.5
°
247.6
°
 to 292.5
°
292.6
°
 to 337.5
°
337.6
°
 to 22.5
°
Correction data
Page: F
Address: 69
01
02
03
04
05
06
07
08
Fig. 5-1-8.
5-21
DCR-IP5/IP5E/IP7BT/IP7E
8. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart (Color reproduction
adjustment frame) Note1
Adjustment Page
F
Adjustment Address
1D
Note1:
Refer to “11. Picture Frame Setting”.
Switch setting:
1)
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
96
00
Set the data.
3
6
97
Set the following data, and press
PAUSE button.
48: DCR-IP5/IP7BT (NTSC)
31: DCR-IP5E/IP7E (PAL)
4
6
01
6F
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note2)
Note2:
The adjustment data will be automatically input to page: F, address:
1D
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
96
00
Set the data.
2
6
97
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
9. F No. & ND Light Quantity Standard Data Input
Compensate the unevenness of the light quantity of the iris meter
and ND filter.
Subject
Clear chart (All white)
(Approx. 27cm from the front of the lens)
Adjustment Page
F
Adjustment Address
24 to 2D
Note1:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
Procedure
1
Adjust the camera direction so that
the whole of the screen is white.
2
0
01
01
Set the data.
3
6
01
BB
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note2)
Note2:
The adjustment data will be automatically input to page: F, address:
24 to 2D.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
5-22
DCR-IP5/IP5E/IP7BT/IP7E
11. LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart (Color reproduction
adjustment frame) Note1
Measurement Point
Display data of page 1 (Note3)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E, 1F, 46 to 49
Specified Value
0FF0 to 1010
Note1:
Refer to “11. Picture Frame Setting”.
Note2:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note3:
This adjustment should be carried out upon completion of the F
No. & ND light quantity standard data input.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
LV data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
0D
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note5)
4
F
10
2E
Set the data, and press PAUSE
button.
5
1
Check that the display data (Note4)
satisfies the specified value.
6
6
01
00
Set the data, and press PAUSE
button.
7
6
3F
10
Set the data.
8
6
01
85
Set the data, and press PAUSE
button.
9
6
02
Check that the data changes to
“01”. (Note6)
Note5:
The adjustment data will be automatically input to page: E, address:
1E, 1F.
Note6:
The adjustment data will be automatically input to page: E, address:
46 to 49.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
F
10
00
Set the data, and press PAUSE
button.
3
6
3F
00
Set the data.
4
0
01
00
Set the data.
10. Mechanical Shutter Adjustment
(DCR-IP7BT/IP7E)
Adjust the period which the mechanical shutter is closed, and
compensate the exposure.
Adjustment Page
F
7
Adjustment Address
70 to 84
1D to 20
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 70 to 84.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
3)
Input the following data to page: 7, addresses: 1D to 20.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
4)
Select page: 0, address: 01, and set data: 00.
Address
1D
1E
1F
20
Data
7A
80
80
7F
Address
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
Data
BD
09
6F
07
77
06
A6
05
43
04
E5
58
2B
6D
D9
6D
4D
5D
D9
40
22