Sony DCR-IP5 / DCR-IP5E / DCR-IP7BT / DCR-IP7E (serv.man3) Service Manual ▷ View online

5-11
DCR-IP5/IP5E/IP7BT/IP7E
00 to 0F
10
11
12
13
14 to 19
1A
1B
1C
1D to 1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38 to 3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
CAP FG duty adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
CAP FG duty adj.
Emergency memory address
T reel FG duty adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
Switching position adj.
XREC ACT adj.
Fixed data-1
Chroma BPF fo adj.
Pch LMS adj.
Address
Remark
Initial value
1-2-2.
INITIALIZATION OF C, 4, 8, 9 PAGE DATA
1. Initializing the C, 4, 8, 9 Page Data
Note1: If “Initializing the C, 4, 8, 9 Page Data” is performed, all
data of the E page, F page and 7 page will be initialized.
(It is impossible to initialize a single page.)
Note2:
If the C, 4, 8, 9 page data has been initialized, following adjustments
need to be performed again.
1) Modification of C, 4, 8, 9 page data
2) Serial No. input
3) Servo and RF system adjustments
4) Video system adjustments
5) Color view finder system adjustments
6) LCD system adjustments
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
4
Adjusting Address
00 to FF
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
9
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
81
00
Set the data, and press PAUSE
button.
3
3
80
0F
Set the data, and press PAUSE
button.
4
3
80
Check that the data changes to
“1F”.
5
Perform “Modification of C, 4, 8,
9 Page Data”.
2. Modification of C, 4, 8, 9 Page Data
If the C, 4, 8, 9 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C, 4, 8, 9 Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press the PAUSE
button.
3. C Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, 4, 8,
9 Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, 4, 8,
9 Page Data”.)
00
00
00
00
80
80
70
00
00
00
00
00
00
00
00
00
00
00
00
00
80
80
19
9A
19
9A
00
00
00
00
07
00
00
00
00
00
00
00
00
00
00
00
00
00
00
5-12
DCR-IP5/IP5E/IP7BT/IP7E
41
85
86
5E
36
90
6F
AE
7C
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D to 6F
70
71
72
73
74
75
76
77
78 to 7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90 to 93
94
95
96
97 to FF
Pch LMS adj.
Mch LMS adj.
Pch AEQ adj.
Mch AEQ adj.
Pch AEQ adj.
Mch AEQ adj.
AGC adj.
Read clock fo adj.
Fixed data-1
Timing ATF center value adj.
Fixed data-1
VCO adj. (EVF)
Bright adj. (EVF)
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
VCO adj. (EVF)
Fixed data-1
VCO adj.(LCD)
V COM adj. (LCD)
Bright adj. (LCD)
Black limit adj.(LCD)
PSIG GRAY adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
Center level adj. (LCD)
Fixed data-1
VCO adj. (LCD)
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-1
Address
Remark
Initial value
Address
Remark
Initial value
Table. 5-1-6.
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
2B
2B
2E
2E
28
A1
00
00
00
00
00
00
00
00
7B
A8
9D
7E
33
92
70
A1
EB
0C
C Page
5-13
DCR-IP5/IP5E/IP7BT/IP7E
4. 4 Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, 4, 8,
9 Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, 4, 8,
9 Page Data”.)
6. 9 Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, 4, 8,
9 Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, 4, 8,
9 Page Data”.)
00
00
00
00 to 08
09
0A
0B
0C to 11
12
13
14 to 24
25
26 to E4
E5
E6 to FF
Fixed data-1
Serial No. input
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Table. 5-1-9.
00 to E9
EA
EB to FF
60 (*1)
00 (*2)
Fixed data-1
Fixed data
Fixed data-1
Table. 5-1-7.
*1: Mechanical microprocessor ver. 1.0.
*2: Mechanical microprocessor ver. 2.0. or later.
Confirmation of the mechanical microprocessor ver. 1.0:
(VC-263 board IC1103)
Order Page Address Data
Procedure
1
3
FF
The data should be “53”.
2
3
F8
The data should be “10”.
5. 8 Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, 4, 8,
9 Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, 4, 8,
9 Page Data”.)
Address
Remark
00 to 0F
10
11 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-8.
Address
Remark
Initial value
5-14
DCR-IP5/IP5E/IP7BT/IP7E
1-2-3.
INITIALIZATION OF B PAGE DATA
(DCR-IP7BT/IP7E)
Switch setting:
POWER ................................................................. MEMORY
Memory Stick slot ............................... Insert a Memory Stick
1. Initializing the B Page Data
Note: If  the B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of B page data
2) Writing the network default setting value
Adjusting page
B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
5
0E
00
Set the data, and press PAUSE
button.
3
5
01
F3
Set the data, and press PAUSE
button.
4
5
00
01
Set the data, and press PAUSE
button.
5
Wait for 3 sec.
6
5
0E
Check that the data changes to
“01”.
7
Perform “Modification of B Page
Data”.
2. Modification of B Page Data
If the B page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press PAUSE
button.
3. Writing the Network Default Setting Value
Writing method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
5
01
E7
Set the data, and press PAUSE
button.
3
5
09
80
Set the data, and press PAUSE
button.
4
5
0A
Set the following data, and press
PAUSE button.
03: US model
01: Except US model
5
5
00
01
Set the data, and press PAUSE
button.
6
5
0E
Check that the data is “01”.
7
0
01
00
Set the data.
4. B Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B Page
Data”.)
Address
Remark
00 to 0F
10
11 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-10.
Page of 63
Display