Sony DCR-IP5 / DCR-IP5E / DCR-IP7BT / DCR-IP7E (serv.man3) Service Manual ▷ View online

5-35
DCR-IP5/IP5E/IP7BT/IP7E
4. PSIG GRAY Adjustment (PD-142 Board)
Set the PSIG signal level to an appropriate level.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 6 of CN3104 (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
89
Specified Value
A = 5.00 ± 0.05V
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
89
Change the data and set the PSIG
signal level (A) to the specified
value.
(The data should be “00” to “7F”.)
3
C
89
Press PAUSE button.
4
0
01
00
Set the data.
5. Contrast Adjustment (PD-142 Board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 1 of CN3104 (VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
8C
Specified Value
A = 3.70 ± 0.05V
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
8C
Change the data and set the
voltage (A) between the 3 steps
peak and pedestal to the specified
value.
(The data should be “00” to “7F”.)
3
C
8C
Press PAUSE button.
4
0
01
00
Set the data.
5
Check that the specified value of
“Bright Adjustment” is satisfied.
Fig. 5-1-20.
Fig. 5-1-21.
3 steps peak
Pedestal
A
2H
A
2H
5-36
DCR-IP5/IP5E/IP7BT/IP7E
6. Center Level Adjustment (PD-142 Board)
Set the video signal center level of LCD panel to an appropriate
level.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 1 of CN3104 (VG)
Measuring Instrument
Digital voltmeter
Adjustment Page
C
Adjustment Address
8D
Specified Value
A = 7.00 ± 0.05Vdc
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
8D
Change the data and set the DC
voltage (A) to the specified value.
(The data should be “00” to “7F”.)
3
C
8D
Press PAUSE button.
4
0
01
00
Set the data.
7. V-COM Adjustment (PD-142 Board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
C
Adjustment Address
86
Specified Value
The brightness difference between the
section A and section B is minimum.
Note:
This adjustment should be carried out upon completion of the
following adjustments.
Bright adjustment, Black limit adjustment, Contrast adjustment,
Center level adjustment
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
86
Change the data so that the
brightness of the section A and
that of the section B is equal.
(The data should be “80” to “BF”.)
3
C
86
Subtract 1 from the data.
4
C
86
Press PAUSE button.
5
0
01
00
Set the data.
Fig. 5-1-22.
A
A
A
A
B
B
B
B
5-37
DCR-IP5/IP5E/IP7BT/IP7E
8. White Balance Adjustment (PD-142 Board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
8A, 8B
Specified Value
The LCD screen should not be colored.
Note1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC3101
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
8A
85
Set the data, and press PAUSE
button.
3
C
8B
86
Set the data, and press PAUSE
button.
4
C
8B
Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5
C
8A
Change the data so that the LCD
screen is not colored.
6
C
8A
Press PAUSE button.
7
C
8B
Change the data so that the LCD
screen is not colored.
8
C
8B
Press PAUSE button.
9
C
8B
If the LCD screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
5-38
DCR-IP5/IP5E/IP7BT/IP7E
5-2. MECHANISM SECTION
ADJUSTMENT
On the mechanism section adjustment
For detail of mechanism section adjustments, checks, and
replacement of mechanism parts, refer to the separate volume
“MICRO MV MECHANICAL ADJUSTMENT MANUAL 1
 V Mechanism ”.
2-1.
Adjustment Remote Commander
Connect the adjustment remote commander to A/V jack via the
multi-cable for service (J-6082-535- A).
2-2.
OPERATING WITHOUT CASSETTE
1)
Connect the adjustment remote commander.
2)
Turn on the HOLD switch of the adjustment remote
commander.
3)
Close the cassette compartment without loading a cassette and
complete loading.
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: 9, address: 74, set data: 01, and press the PAUSE
button.
6)
Select page: 9, address: 81, set data: 01, and press the PAUSE
button.
7)
Select page: 9, address: C4, set data: 02, and press the PAUSE
button.
8)
Disconnect the power supply of the unit.
By carrying out the above procedure, the unit can be operated
without loading a cassette. Never do opening or closing of the
cassette compartment under this condition.
Be sure to carry out “Procedure checking operations” after
checking the operations.
Set the following data to page: D, address: 10, if the forced
power supply ON mode is to be used together.
Forced VTR power supply ON mode ............................. 02
Forced CAMERA power supply ON mode ................... 01
[Procedure after checking operations]
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 9, address: 74, set data: 00, and press the PAUSE
button.
3)
Select page: 9, address: 81, set data: 00, and press the PAUSE
button.
4)
Select page: 9, address: C4, set data: 00, and press the PAUSE
button.
5)
Select page: 0, address: 01, and set data: 00.
6)
Disconnect the power supply of the unit.
2-3.
TAPE PATH ADJUSTMENT
1. Preparation for Adjustment
1)
Clean the tape running side (tape guide, capstan shaft, pinch
roller, etc.).
2)
Connect an oscilloscope to CPC of VC-263 board.
Channel 1: VC-263 board, CPC Pin qk (Note)
External trigger: VC-263 board CPC Pin qf
Note:
Connect a 75
 resistor between Pins qk of CPC and ws (GND).
3)
Playback the alignment tape for tracking. (XH8-1)
4)
Connect the adjustment remote commander and turn the HOLD
switch to the ON position.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: 9, address: BC, set data: 0D, and press the PAUSE
button.
7)
Select page: 9, address: 81, set data: 62, and press the PAUSE
button.
8)
Select page: 0, address: 01, and set data: 00.
9)
Select page: 3, address: 0A, set data: 40, and press the PAUSE
button.
10) Check that the data of page: 3, address: 0B changes from “40”
to “00”.
11) Rotate the HOLDOFF knob of the oscilloscope so that the
flattest waveform is displayed.
12) Check that the oscilloscope RF waveform is normal at the
entrance and exit.
If not normal, adjust according to the separate volume
“MICRO MV MECHANICAL ADJUSTMENT MANUAL 1
V Mechanism ”.
CPC of VC-263 board
Fig. 5-2-1.
2. Processing after Completing Operations:
1)
Connect the adjustment remote commander and set the HOLD
switch to the ON position.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 9, address: BC, set data: 00, and press the PAUSE
button.
4)
Select page: 9, address: 81, set data: 22, and press the PAUSE
button.
5)
Select page: 0, address: 01, and set data: 00.
Pin No.
1
3
5
7
9
11
13
15
17
19
21
Signal Name
HI XRESET
PWE
HI RXD
MDO
MD2
SWP SO
PLLON DIA
XRESET SW
QTM1
CPC ENV OUT
REG GND
Pin No.
2
4
6
8
10
12
14
16
18
20
22
Signal Name
EVER 3V
HI TXD
HI TEST A
DIS HISIO
RAW PBH
SCK3
SWP
QTM2
RF MON OUT
D 2.8V
REG GND
5msec
CH1
Trigger
Page of 63
Display

Click on the first or last page to see other DCR-IP5 / DCR-IP5E / DCR-IP7BT / DCR-IP7E (serv.man3) service manuals if exist.