DOWNLOAD Sony DCR-IP1 / DCR-IP1E (serv.man4) Service Manual ↓ Size: 743.08 KB | Pages: 66 in PDF or view online for FREE

Model
DCR-IP1 DCR-IP1E (serv.man4)
Pages
66
Size
743.08 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-ip1-dcr-ip1e-sm4.pdf
Date

Sony DCR-IP1 / DCR-IP1E (serv.man4) Service Manual ▷ View online

DCR-IP1/IP1E
6-30
15. LV Standard Data Input 
RadarW
RadarW
RadarW
Adjust the normal coefficient of the light value at 3200K.
Subject
Clear chart (All white frame)
Measurement Point
Displayed data of page: 1 (Note 4)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note 1:
Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, turn the power of unit OFF/ON.
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Wait for 6 seconds.
3
6
01
0D
Press PAUSE button. (Note 5)
4
6
02
Check the data changes to
“01”.
5
0
03
1E
6
1
Check that the displayed data
(Note 4) satisfied the
specified value.
Note 5:
The adjustment data will be automatically input to page:
F, address: 1A, 1B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
03
00
3
0
01
00
16. Auto White Balance Adjustment 
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart (All white frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
14
Adjustment Address
32 to 35, 44 to 47
F4 to FF
Note 1:
Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
If reading/writing data on pages 14, set data: 01 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 14 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, turn the power of unit OFF/ON.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
0
01
01
3
F
44
2C
Press PAUSE button.
4
F
45
C0
Press PAUSE button.
5
F
46
5B
Press PAUSE button.
6
F
47
80
Press PAUSE button.
7
6
01
47
Press PAUSE button.
8
6
01
45
Press PAUSE button. (Note 4)
9
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 32 to 35 and page: 14, address: F4 to FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
01
00
3
Remove the C14 filter on the
lens.
DCR-IP1/IP1E
6-31
17. Auto White Balance Check 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Clear chart (All white frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0, 0.4 and 0.1
Measurement Point
Video terminal of
Displayed data of
A/V jack
page: 1 (Note 3)
(75 
Ω terminated)
Measuring Instrument
Vectorscope
Adjusting remote
commander
Specified Value
Fig. 6-1-13
R ratio:
(A) and (B)
2C60 to 2D20
B ratio:
5B20 to 5BE0
InOut data:
8000 to 8BC0
Note 1:
Perform “Auto White Balance Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Checking method:
Order Page Address Data
Procedure
OUTDOOR check
1
Place the C14 filter on the
lens.
2
6
01
3F
Press PAUSE button.
3
Wait for 3 seconds.
4
0
03
04
5
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
6
0
03
05
7
1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
8
Check that the center of the
white luminance point within
the circle shown Fig. 6-1-13
(A)
9
6
01
00
Press PAUSE button.
10
Remove the C14 filter
INDOOR check
11
6
01
0F
Press PAUSE button.
12
Wait for 3 seconds.
13
Check that the center of the
white luminance point within
the circle shown Fig. 6-1-13
(B)
14
6
01
00
Press PAUSE button.
InOut data check
15
Place the ND filter 1.5 (1.0 +
0.4 + 0.1) on the lens.
16
0
03
06
17
1
Check that the displayed data
(Note 3) satisfied the InOut
data specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
03
00
3
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
R-Y
B-Y
0.5mm
1mm
3mm
3mm
Fig. 6-1-13 (A)
Fig. 6-1-13 (B)
R-Y
B-Y
2mm
2mm
DCR-IP1/IP1E
6-32
18. Steady shot Check 
RadarW
RadarW
RadarW
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03MA
Type B
ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified value
PITCH data: 2680 to 5080
YAW data: 2680 to 5080
Note 1:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
Displayed data
Note 2:
 Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) ZOOM ..................................................................... TELE end
2) STEADY SHOT (Menu setting) ....................................... ON
Checking method:
Order Page Address Data
Procedure
  PITCH sensor output check (SE2702 of SE-139 board)
1
0
03
11
2
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the PITCH
data specified value.
  YAW sensor output check (SE2701 of SE-139 board)
3
0
03
12
4
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the YAW
data specified value.
5
0
03
00
  Steady shot operation check
6
Shake the set vertically and
horizontally to check that the
steady shot function operates
normally.
19. CCD Defect Check 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Not required
Measurement Point
Check on the monitor TV
Measuring Instrument
Note:
 Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Checking method:
Order Page Address Data
Procedure
1
6
01
07
Press PAUSE button.
2
6
1F
CC
3
6
40
03
4
Check on the monitor screen
that no defect is found.
5
6
40
04
6
Check on the monitor screen
that no defect is found.
7
6
40
05
8
Check on the monitor screen
that no defect is found.
9
6
40
06
10
Check on the monitor screen
that no defect is found.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
40
00
3
6
1F
00
DCR-IP1/IP1E
6-33
1-4.
LCD SYSTEM ADJUSTMENTS
Before perform the LCD system adjustments, check that the data
of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Note 1:
Taken an extreme care not to destroy the liquid crystal
display module by static electricity when replacing it.
Note 2:
Set the “LCD BRIGHT”, “LCD COLOR” to the center
with the menu settings of the touch panel.
Note 3:
Open the LCD panel during the LCD system adjustment.
1.
LCD Automatic Adjustment (PD-199 board)
RadarW
RadarW
RadarW
RadarW
RadarW
This adjustment does the following items automatically.
   VCO Adjustment
   RGB AMP Adjustment
   Contrast Adjustment
   PSIG black adjustment
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Adjustment Page
C
Adjustment Address
8C, 8D (VCO Adjustment)
8F (RGB AMP Adjustment)
94 (Contrast Adjustment)
97 (PSIG black adjustment)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
NTSC model: DCR-IP1
PAL model: DCR-IP1E
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
00
5A
Press PAUSE button. (Note 3)
3
3
01
Check the data changes to
“00”. (Note 4)
4
C
8C
Read the data and this data is
named D
8C
.
5
Convert D
8C
 to decimal notation,
and obtain D
8C
’. (Note 5)
6
Calculate D
8D
’ using following
equations. (decimal calculation)
D
8D
’ = D
8C
’ + 20 (NTSC model)
D
8D
’ = D
8C
’ – 20 (PAL model)
7
Convert D
8D
’ to a hexadecimal
number, and obtain D
8D
. (Note 5)
8
C
8D
D
8D
Press PAUSE button.
9
0
01
00
Note 3:
The adjustment data will be automatically input to page:
C, address: 8C, 8F, 94 and 97.
Note 4:
If the data change to “FF”, adjustment has error. Con-
tents of error is written into page: 3, address: 02. See the
following table.
Note 5:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”.
Data of page: 3, address: 02 Contents of error
58
VCO adjustment error
53
RGB AMP adjustment error
54
Contrast adjustment error
56
PSIG black adjustment error
Page of 66
Display

Click on the first or last page to see other DCR-IP1 / DCR-IP1E (serv.man4) service manuals if exist.