Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-ip1-dcr-ip1e-sm4.pdf
Date

Sony DCR-IP1 / DCR-IP1E (serv.man4) Service Manual ▷ View online

DCR-IP1/IP1E
6-18
C Page table
Address
Initial value
Remark
NTSC PAL
43
04
04
44
FF
FF
45
F8
F8
46
12
12
47
2A
2A
48
12
12
49
F8
F8
4A
FF
FF
Pch LMS adj.
4B
04
04
4C
FE
FE
4D
FF
FF
4E
01
01
4F
00
00
50
00
00
51
00
00
52
00
00
53
00
00
54
00
00
55
01
01
56
FF
FF
57
FE
FE
58
04
04
59
FF
FF
5A
F8
F8
5B
12
12
5C
2A
2A
Mch LMS adj.
5D
12
12
5E
F8
F8
5F
FF
FF
60
04
04
61
FE
FE
62
FF
FF
63
01
01
64
00
00
65
00
00
66
00
00
67 to 6A
Fixed data-1 (Initialized data)
6B
48
48
AGC adj.
6C to 6F
Fixed data-1 (Initialized data)
70
00
00
71
00
00
72
00
00
73
00
00
Timing ATF center value adj.
74
00
00
75
00
00
76
00
00
77
00
00
Address
Initial value
Remark
NTSC PAL
78 to 7A
Fixed data-1 (Initialized data)
7B
7C
Fixed data-2
7D to 8B
Fixed data-1 (Initialized data)
8C
6A
84
LCD automatic adj. (VCO adj.)
8D
84
6A
8E
9A
9A
V-COM adj.
8F
88
88
LCD automatic adj. (RGB AMP adj.)
90, 91
Fixed data-1 (Initialized data)
92
A0
A0
Transmissive mode white balance adj.
93
A0
A0
94
44
44
LCD automatic adj. (Contrast adj.)
95, 96
Fixed data-1 (Initialized data)
97
A0
A0
LCD automatic adj. (PSIG black adj.)
98 to A1
Fixed data-1 (Initialized data)
A2
Fixed data-2
A3 to B6
Fixed data-1 (Initialized data)
B7
8C
8C
Reflective mode white balance adj.
B8
5E
5E
B9, BA
Fixed data-1 (Initialized data)
BB
59
59
S VIDEO OUT Y level adj.
BC
70
70
S VIDEO OUT chroma level adj.
BD
50
50
BE to DC
Fixed data-1 (Initialized data)
DD
00
00
DE
00
00
Node unique ID No. input
DF
00
00
E0 to E6
Fixed data-1 (Initialized data)
E7
Fixed data-2
E8 to F8
Fixed data-1 (Initialized data)
F9
Fixed data-2
FA to FF
Fixed data-1 (Initialized data)
DCR-IP1/IP1E
6-19
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. (Except “66MHz/54MHz Origin Oscillation Check”)
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
1.
66MHz/54MHz Origin Oscillation Check
(CD-458 board) (66MHz: NTSC/54MHz: PAL)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
R5027 (Pin td of IC5001) on CD-458
board or
CL403 (Pin <zcm of IC401) on VC-333
board
Measuring Instrument
Frequency counter
Specified value
f = 33000000 
± 921 Hz (NTSC)
f = 27000000 
± 755 Hz (PAL)
Note:
NTSC model: DCR-IP1
PAL model: DCR-IP1E
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
Fig. 6-1-6
R5027
R5028
IC5001
Measurement
Point
CD-458 BOARD
IC401
IC301
Measurement
Point
VC-333 BOARD
DCR-IP1/IP1E
6-20
2.
HALL Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
For detecting the position of lens iris and ND filter, adjust the hall
AMP gain and offset.
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
19
Adjustment Address
13 to 18, 92
24 to 27
Specified value 1
D4 to DC
Specified value 2
24 to 2C
Specified value 3
D2 to DE
Specified value 4
22 to 2E
Note 1:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
IRIS displayed data
ND displayed data
Note 2:
If reading/writing data on pages 19, set data: 01 to page:
0, address: 10, and then select pages 9. By this data set-
ting, the pages 19 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
6D
Press PAUSE button. (Note 3)
3
6
02
Check the data changes to “01”.
4
6
01
00
Press PAUSE button.
Note 3:
The adjustment data will be automatically input to page:
F, address: 13 to 18, 92 and page: 19, address: 24 to 27.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
2
6
01
01
Press PAUSE button.
3
6
01
03
Press PAUSE button.
4
1
Check that the IRIS dis-
played data (Note 1) satisfied
the specified value 1.
5
6
01
01
Press PAUSE button.
6
1
Check that the IRIS dis-
played data (Note 1) satisfied
the specified value 2.
7
6
01
6B
Press PAUSE button.
8
6
01
69
Press PAUSE button.
9
1
Check that the ND displayed
data (Note 1) satisfied the
specified value 3.
10
6
01
6B
Press PAUSE button.
11
1
Check that the ND displayed
data (Note 1) satisfied the
specified value 4.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
03
00
3
0
01
00
DCR-IP1/IP1E
6-21
3.
MR Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
The inner focus lens MR adjustment is carried out automatically.
In whichever case, the focus will be deviated during auto focus-
ing/manual focusing.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified value 1
40 to C0
Specified value 2
03 to 78
Specified value 3
88 to FD
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
Perform “Flange Back Adjustment” after this adjustment.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
BD
Press PAUSE button. (Note 5)
3
6
02
Check the data changes to
“01”.
4
F
5A
5B
5C
5D
5
F
5E
60
62
64
6
F
5F
61
63
65
Note 5:
The adjustment data will be automatically input to page:
F, address: 58, 5A to 65.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
01
00
Check that the data of each
address satisfied the specified
value 1.
Check that the data of each
address satisfied the specified
value 2.
Check that the data of each
address satisfied the specified
value 3.
Page of 66
Display