DCR-IP1/IP1E
6-14
7.
1E Page table
Note 1:
If reading/writing data on pages 1E, set data: 01 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 1E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 11
Fixed data-1 (Initialized data)
12
13
Fixed data-2
14 to 17
Fixed data-1 (Initialized data)
18
19
1A
1B
1C
Fixed data-2
1D
1E
1F
20 to 7B
Fixed data-1 (Initialized data)
7C
Fixed data-2
7D to D1
Fixed data-1 (Initialized data)
D2
D3
D4
Fixed data-2
D5
D6 to D8
Fixed data-1 (Initialized data)
D9
DA
DB
Fixed data-2
DC
DD to FA
Fixed data-1 (Initialized data)
FB
FC
FD
Fixed data-2
FE
FF
6.
19 Page table
Note 1:
If reading/writing data on pages 19, set data: 01 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 19 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 14
Fixed data-1 (Initialized data)
15
Fixed data-2
16 to 23
Fixed data-1 (Initialized data)
24
28
28
25
D8
D8
Hall adj.
26
28
28
27
D8
D8
28 to 53
Fixed data-1 (Initialized data)
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
Fixed data-2
61
62
63
64
65
66
67
68
69
6A
6B
6C to A6
Fixed data-1 (Initialized data)
A7
A8
Fixed data-2
A9 to FF
Fixed data-1 (Initialized data)
DCR-IP1/IP1E
6-15
8.
1F Page table
Note 1:
If reading/writing data on pages 1F, set data: 01 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
AD to AF
Fixed data-1 (Initialized data)
B0
B1
Fixed data-2
B2
B3
Fixed data-1 (Initialized data)
B4
Fixed data-2
B5 to B7
Fixed data-1 (Initialized data)
B8
B9
Fixed data-2
BA
BB
Fixed data-1 (Initialized data)
BC
Fixed data-2
BD
Fixed data-1 (Initialized data)
BE
Fixed data-2
BF to C9
Fixed data-1 (Initialized data)
CA
CB
Fixed data-2
CC to FF
Fixed data-1 (Initialized data)
DCR-IP1/IP1E
6-16
1-2-4.
Initialization of 4, 8, 9, C Page Data
Note:
Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of 4, 8, 9, C Page Data
Note1:
If “Initialization of Pages 4, 8, 9, C” is executed, all data
on pages 4, 8, 9, C are initialized. (Only an individual
page cannot be initialized)
Note 2:
If the 4, 8, 9, C page data has been initialized, the fol-
lowing adjustments need to be performed again.
1) Modification of 4, 8, 9, C page data
2) LCD system adjustments (if all areas were initialized)
3) Node unique ID No. input (if all areas were initial-
ized)
4) Servo, RF system adjustments (if all areas were ini-
tialized)
5) Video system adjustments (if all areas were initial-
ized)
Adjustment Page
4
Adjustment Address
00 to FF
Adjustment Page
8
Adjustment Address
00 to FF
Adjustment Page
9
Adjustment Address
00 to FF
Adjustment Page
C
Adjustment Address
10 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
Set the following data, and
press PAUSE button. (Note 3)
If all areas are initialized:
3
3
81
00
If other than adjustment
address is initialized:
01
4
3
80
0F
Press PAUSE button.
5
3
80
Check the data changes to
“1F”.
6
Perform “Modification of 4,
8, 9, C Page Data”
Note 3:
If other than adjustment address was initialized, the ad-
justed data is not initialized.
2.
Modification of 4, 8, 9, C Page Data
If the 4, 8, 9, C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table. If different, change them to the adjustment
initial values.
Processing after Completing Modification 4, 8, 9, C page
data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
3.
4 Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 4, 8, 9, C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 4, 8, 9, C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
4.
8 Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 4, 8, 9, C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 4, 8, 9, C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 9E
Fixed data-1 (Initialized data)
9F
Fixed data-2
A0 to AD
Fixed data-1 (Initialized data)
AE
AF
Fixed data-2
B0
B1
Fixed data-1 (Initialized data)
B2
Fixed data-2
B3 to FF
Fixed data-1 (Initialized data)
DCR-IP1/IP1E
6-17
5.
9 Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 4, 8, 9, C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 4, 8, 9, C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 0E
Fixed data-1 (Initialized data)
0F
10
Fixed data-2
11
12 to B6
Fixed data-1 (Initialized data)
B7
Fixed data-2
B8 to FF
Fixed data-1 (Initialized data)
6.
C Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 4, 8, 9, C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 4, 8, 9, C Page Data”)
Address
Initial value
Remark
NTSC PAL
10
00
00
11
00
00
CAP FG adj.
12
00
00
13
00
00
14 to 19
Fixed data-1 (Initialized data)
1A
80
80
1B
80
80
CAP FG adj.
1C
70
70
1D
Fixed data-1 (Initialized data)
1E
00
00
CAP FG adj.
1F
00
00
20
00
00
21
00
00
22
00
00
23
00
00
24
00
00
25
00
00
Emergency memory address
26
00
00
27
00
00
28
00
00
29
00
00
2A
00
00
2B
00
00
2C
80
80
T reel FG duty adj.
2D
Fixed data-1 (Initialized data)
2E
80
80
CAP FG adj.
2F
Fixed data-1 (Initialized data)
30
19
19
31
9A
9A
Playback switching position adj.
32
19
19
33
9A
9A
34
00
00
35
00
00
Recording switching position adj.
36
00
00
37
00
00
38 to 3B
Fixed data-1 (Initialized data)
3C
07
07
Chroma BPF f
0
 adj.
3D
00
00
3E
00
00
3F
00
00
Pch LMS adj.
40
01
01
41
FF
FF
42
FE
FE