SECTION 6
ADJUSTMENTS
DCR-IP1/IP1E
RMT-832
ADJ
Revision History
Revision History
Ver 1.0  2003. 10
Link
Link
Adjusting items when replacing main parts and boards
Before starting adjustments
Adjusting items when replacing main parts and boards
Before starting adjustments
LCD SYSTEM ADJUSTMENTS
CAMERA SYSTEM ADJUSTMENTS
INITIALIZATION OF 4, 8, 9, A, B, C, D, E, F, 14, 
19, 1B, 1E, 1F PAGE DATA
PREPARATIONS BEFORE ADJUSTMENTS
CAMERA SECTION ADJUSTMENTS
LCD SYSTEM ADJUSTMENTS
CAMERA SYSTEM ADJUSTMENTS
INITIALIZATION OF 4, 8, 9, A, B, C, D, E, F, 14, 
19, 1B, 1E, 1F PAGE DATA
PREPARATIONS BEFORE ADJUSTMENTS
CAMERA SECTION ADJUSTMENTS
TAPE PATH ADJUSTMENT
OPERATING WITHOUT CASSETTE
ADJUSTMENT REMOTE COMMANDER
MECHANISM SECTION ADJUSTMENTS
TAPE PATH ADJUSTMENT
OPERATING WITHOUT CASSETTE
ADJUSTMENT REMOTE COMMANDER
MECHANISM SECTION ADJUSTMENTS
AUDIO SYSTEM ADJUSTMENTS
VIDEO SYSTEM ADJUSTMENTS
SERVO AND RF SYSTEM ADJUSTMENTS
SYSTEM CONTROL SYSTEM ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS
VIDEO SECTION ADJUSTMENTS
AUDIO SYSTEM ADJUSTMENTS
VIDEO SYSTEM ADJUSTMENTS
SERVO AND RF SYSTEM ADJUSTMENTS
SYSTEM CONTROL SYSTEM ADJUSTMENTS
PREPARATIONS BEFORE ADJUSTMENTS
VIDEO SECTION ADJUSTMENTS
SERVICE MODE
DATA PROCESS
ADJUSTMENT REMOTE COMMANDER
SERVICE MODE
SERVICE MODE
DATA PROCESS
ADJUSTMENT REMOTE COMMANDER
SERVICE MODE
Sony EMCS Co.
2003J0500-1
  ©2003.10
Published by DI CS Strategy Div
9-876-267-51
Contents of LEVEL 2 and LEVEL 3 Service Manual
CONTENTS
1. SERVICE NOTE
2. DISASSEMBLY
3. BLOCK DIAGRAMS
4. PRINTED WIRING BOARDS AND
SCHEMATIC DIAGRAMS
5. REPAIR PARTS LIST
LEVEL 2
a
a
OVERALL
POWER
DH-041, IF-108, MS-153,
PD-199, SE-139 BOARD
FP-080, FP-081, FP-228,
FP-723, FP-731, FP-732,
FP-733, FP-734, FP-769
FLEXIBLE
EXPLODED VIEWS
ELECTRICAL PARTS
LEVEL 3


CD-458, VC-333 BOARD
a
(CD-458, VC-333 BOARD)
DCR-IP1/IP1E
— 2 —
TABLE OF CONTENTS
6.
ADJUSTMENTS
Before Starting Adjustments ····················································· 6-1
1-1.
Adjusting Items when Replacing
Main Parts ········································································ 6-2
6-1.
Camera Section Adjustments ··········································· 6-4
1-1.
Preparations before Adjustments (CAMERA Section) ··· 6-4
1-1-1. List of Service Tools ························································ 6-4
1-1-2. Preparations ····································································· 6-5
1-1-3. Precaution ········································································ 6-6
1.
Setting the Switch ···························································· 6-6
2.
Order of Adjustments ······················································ 6-6
3.
Subjects ··········································································· 6-6
1-2.
Initialization of 4, 8, 9, A, B, C, D, E, F, 14, 19, 1B,
1E, 1F Page Data ····························································· 6-7
1-2-1. Initialization of A, D Page Data ······································ 6-7
1.
Initializing A, D Page Data ·············································· 6-7
2.
Modification of A, D Page Data ······································ 6-7
3.
A Page Table ···································································· 6-7
4.
D Page Table ···································································· 6-8
1-2-2. Initialization of B, 1B Page Data ····································· 6-9
1.
Initializing B, 1B Page Data ············································ 6-9
2.
Modification of B, 1B Page Data ···································· 6-9
3.
B Page Table ···································································· 6-9
4.
1B Page Table ·································································· 6-9
1-2-3. Initialization of E, F, 14, 19, 1E, 1F Page Data ············· 6-10
1.
Initializing of E, F, 14, 19, 1E, 1F Page Data ················ 6-10
2.
Modification of E, F, 14, 19, 1E, 1F Page Data ············· 6-10
3.
E Page Table ·································································· 6-11
4.
F Page Table ·································································· 6-12
5.
14 Page Table ································································· 6-13
6.
19 Page Table ································································· 6-14
7.
1E Page Table ································································ 6-14
8.
1F Page Table ································································ 6-15
1-2-4. Initialization of 4, 8, 9, C Page Data ····························· 6-16
1.
Initializing of 4, 8, 9, C Page Data ································ 6-16
2.
Modification of 4, 8, 9, C Page Data ····························· 6-16
3.
4 Page Table ··································································· 6-16
4.
8 Page Table ··································································· 6-16
5.
9 Page Table ··································································· 6-17
6.
C Page Table ·································································· 6-17
1-3.
Camera System Adjustments ········································· 6-19
1.
66MHz/54MHz Origin Oscillation Check
(CD-458 Board) (66MHz: NTSC/54MHz: PAL) ·········· 6-19
2.
Hall Adjustment ····························································· 6-20
3.
MR Adjustment ····························································· 6-21
4.
Flange Back Adjustment
(Using the minipattern box) ·········································· 6-22
5.
Flange Back Adjustment
(Using the flange back adjustment chart
and subject more than 500 m away) ······························ 6-23
5-1.
Flange Back Adjustment (1) ·········································· 6-23
5-2.
Flange Back Adjustment (2) ·········································· 6-23
6.
Flange Back Check ························································ 6-24
7.
Picture Frame Setting (Center frame) ··························· 6-25
8.
F No. & ND Light Quality Standard Data Input ··········· 6-25
9.
MAX GAIN Adjustment ··············································· 6-26
10.
Mechanical Shutter Adjustment ···································· 6-26
11.
Picture Frame Setting
(Color reproduction adjustment frame) ························· 6-27
12.
Color Reproduction Adjustment ···································· 6-28
13.
Picture Frame Setting (All white frame) ······················· 6-29
14.
Auto White Balance Standard Data Input ····················· 6-29
15.
LV Standard Data Input ················································· 6-30
16.
Auto White Balance Adjustment ··································· 6-30
17.
Auto White Balance Check ··········································· 6-31
18.
Steady shot Check ························································· 6-32
Section
Title
Page
Section
Title
Page
19.
CCD Defect Check ························································ 6-32
1-4.
LCD System Adjustments ············································· 6-33
1.
LCD Automatic Adjustment (PD-199 Board) ··············· 6-33
2.
V-COM Adjustment (PD-199 Board) ···························· 6-34
3.
Transmissive Mode White Balance Adjustment
(PD-199 Board) ····························································· 6-34
4.
Reflective Mode White Balance Adjustment
(PD-199 Board) ····························································· 6-35
6-2.
Mechanism Section Adjustments ·································· 6-36
2-1.
Adjustment Remote Commander ·································· 6-36
2-2.
Operating Without Cassette ··········································· 6-36
2-3.
Tape Path Adjustment ···················································· 6-37
1.
Preparation for Adjustment ··········································· 6-37
2.
Processing after Completing Operations ······················· 6-37
6-3.
Video Section Adjustment ············································· 6-38
3-1.
Preparations before Adjustments ··································· 6-38
3-1-1. Equipment Required ······················································ 6-38
3-1-2. Precautions on Adjusting ··············································· 6-39
3-1-3. Connecting Equipment ·················································· 6-39
3-1-4. Alignment Tapes ···························································· 6-40
3-1-5. Input/Output Level and Impedance ······························· 6-40
3-2.
System Control System Adjustments ···························· 6-41
1.
Initialization of 4, 8, 9, A, B, C, D, E, F, 14, 19,
1B, 1E, 1F Page Data ···················································· 6-41
2.
Touch Panel Adjustment ················································ 6-41
3.
Node Unique ID No. Input ············································ 6-42
3-3.
Servo and  RF System Adjustments ······························ 6-44
1.
CAP FG Adjustment (VC-333 Board) ·························· 6-44
2.
T Reel FG Duty Adjustment (VC-333 Board) ·············· 6-45
3.
Playback Switching Position Adjustment
(VC-333 Board) ····························································· 6-45
4.
Recording Switching Position Adjustment
(VC-333 Board) ····························································· 6-46
5.
Timing ATF Center Value Adjustment
(VC-333 Board) ····························································· 6-46
6.
AGC Adjustment (VC-333 Board) ································ 6-47
7.
Pch LMS Adjustment (VC-333 Board) ························· 6-47
8.
Mch LMS Adjustment (VC-333 Board) ························ 6-48
9.
Error Rate Check (VC-333 Board) ································ 6-48
3-4.
Video System Adjustments ············································ 6-49
1.
Chroma BPF f
0
 Adjustment (VC-333 Board) ················ 6-49
2.
S VIDEO OUT Y Level Adjustment
(VC-333 Board) ····························································· 6-49
3.
S VIDEO OUT Chroma Level Adjustment
(VC-333 Board) ····························································· 6-50
4.
VIDEO OUT Level Check (VC-333 Board) ················· 6-51
3-5.
Audio System Adjustments ··········································· 6-52
1.
Overall Level Characteristics Check ····························· 6-52
2.
Overall Distortion Check ··············································· 6-52
3.
Overall Noise Level Check ············································ 6-52
6-4.
Service Mode ································································· 6-53
4-1.
Adjustment Remote Commander ·································· 6-53
1.
Using the Adjustment Remote Commander ·················· 6-53
2.
Precautions Upon Using the Adjustment
Remote Commander ······················································ 6-53
4-2.
Data Process ·································································· 6-54
4-3.
Service Mode ································································· 6-55
1.
Setting the Test Mode ···················································· 6-55
2.
Emergence Memory Address ········································ 6-55
2-1.
C Page Emergence Memory Address ···························· 6-55
2-2.
EMG Code (Emergency Code) ····································· 6-56
2-3.
MSW Code ···································································· 6-57
3.
Bit Value Discrimination ··············································· 6-58
4.
Switch Check (1) ··························································· 6-58
5.
Switch Check (2) ··························································· 6-59
6.
Up Load Flag Check ······················································ 6-60
DCR-IP1/IP1E
— 3 —
*
 The color reproduction frame is shown on page 6-63
Section
Title
Page
6-1.
IC701 Check ·································································· 6-60
6-2.
IC801 Check ·································································· 6-60
6-3.
IC601 Check ·································································· 6-60
7.
MIC Communication Check ········································· 6-60
8.
LED Check ···································································· 6-60
9.
Record of Use Check (1) ··············································· 6-61
10.
Record of Use Check (2) ··············································· 6-61
11.
Record of Self-diagnosis Check ···································· 6-62
DCR-IP1/IP1E
6-1
SECTION 6
ADJUSTMENTS
1.
Before starting adjustments
EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct.
Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.
Procedure 1
Save the EVR data of the machine in which a board is going to be replaced.  Download the saved data after a
board is replaced.
Remove the EEPROM and install it.
(Former board)
(New board)
Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired.  Install the removed
EEPROM to the replaced board.
Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or
installed, save the data from the same model of the same destination, and download it.
After the EVR data is saved and downloaded, check the
respective items of the EVR data.
(Refer to page 6-3 for the items to be checked)
(Machine before starting repair)
(Machine after a board is replaced)
PC
PC
Save the EVR data 
to a personal computer.
Download the saved 
data to a machine.
(Machine to be repaired)
(Machine to be repaired)
(The same model of the same destination)
Save the data.
Download the data.
PC
Page of 66
Display

Sony DCR-IP1 / DCR-IP1E (serv.man4) Service Manual ▷ Download

  • DOWNLOAD Sony DCR-IP1 / DCR-IP1E (serv.man4) Service Manual ↓ Size: 743.08 KB | Pages: 66 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sony DCR-IP1 / DCR-IP1E (serv.man4) in PDF for free, which will help you to disassemble, recover, fix and repair Sony DCR-IP1 / DCR-IP1E (serv.man4) Movie. Information contained in Sony DCR-IP1 / DCR-IP1E (serv.man4) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.