DOWNLOAD Sony DCR-IP1 / DCR-IP1E (serv.man4) Service Manual ↓ Size: 743.08 KB | Pages: 66 in PDF or view online for FREE

Model
DCR-IP1 DCR-IP1E (serv.man4)
Pages
66
Size
743.08 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-ip1-dcr-ip1e-sm4.pdf
Date

Sony DCR-IP1 / DCR-IP1E (serv.man4) Service Manual ▷ View online

DCR-IP1/IP1E
6-22
4.
Flange Back Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
(Using the minipattern box)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
 Siemens star chart with ND filter
for minipattern box (Note 1)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Specified value
Data of page: F, address: 57 is
“00” to “08”
Note 1:
Dark Siemens star chart.
Note 2:
Perform “HALL Adjustment” “MR Adjustment” before
this adjustment.
Note 3:
Perform the adjustment with the lens in horizontal state.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Note 5:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 6:
 Don’t touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) COLOR SLOW S (Menu Setting) ................................... OFF
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 7:
 The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camcorder is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Fig.6-1-7
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
13
Press PAUSE button.
3
6
01
27
Press PAUSE button. (Note 8)
4
6
02
Check the data changes to
“01”.
5
F
57
Check the data is “00” to
“08”.
Note 8:
The adjustment data will be automatically input to page:
F, address: 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
0
01
00
5
Perform “Flange Back
Check”.
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01 Vdc
Output current : more than 3.5 A
DCR-IP1/IP1E
6-23
5-2.
Flange Back Adjustment (2) 
RadarW
RadarW
RadarW
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Specified value
Data of page: F, address: 57 is
“00” to “08”
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 4:
 Don’t touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) COLOR SLOW S (Menu Setting) ................................... OFF
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(Subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
13
Press PAUSE button.
3
Place ND filter on the lens so
that the optimum image is
obtain.
4
6
01
29
Press PAUSE button. (Note 5)
5
6
02
Check the data changes to
“01”.
6
F
57
Check the data is “00” to
“08”.
Note 5:
The adjustment data will be automatically input to page:
F, address: 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
0
01
00
5
Perform “Flange Back
Check”.
5.
Flange Back Adjustment
(Using the flange back adjustment chart and
subject more than 500 m away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
5-1.
Flange Back Adjustment (1) 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Specified value
Data of page: F, address: 57 is
“00” to “08”
Note 1:
Perform “HALL Adjustment” and “MR Adjustment” be-
fore this adjustment.
Note 2:
Perform the adjustment with the lens in horizontal state.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 5:
 Don’t touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) COLOR SLOW S (Menu Setting) ................................... OFF
Preparations before adjustments:
1) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
13
Press PAUSE button.
3
6
01
15
Press PAUSE button. (Note 6)
4
6
02
Check the data changes to
“01”.
5
F
57
Check the data is “00” to
“08”.
Note 6:
The adjustment data will be automatically input to page:
F, address: 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
0
01
00
5
Perform “Flange Back
Adjustment (2)”.
DCR-IP1/IP1E
6-24
6.
Flange Back Check
Subject
 Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1:
 Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Note 2:
When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Preparations before adjustments:
1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
Shoot the Siemens star with
the zoom TELE end.
4
Turn on the auto focus.
5
0
03
0F
6
1
Check that the lens is
focused. (Note 2)
7
6
2C
02
8
Shoot the Siemens star with
the zoom WIDE end.
9
Observe the TV monitor and
check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
6
40
00
3
6
41
00
4
0
03
00
DCR-IP1/IP1E
6-25
7.
Picture Frame Setting (Center frame)
Subject
Clear chart (Center frame)
(1 m from the front of lens)
Measurement Point
Video terminal of A/V jack (75 
terminated)
Measuring Instrument
Monitor TV
Specified Value
A clear chart must be shot in larger
size than nine grids in the center of
frame shown on the screen.
(Fig. 6-1-8)
Note:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) ZOOM .................................................................... WIDE end
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Setting method:
Order Page Address Data
Procedure
1
Shoot a clear chart in the
center of screen with the
zoom at WIDE end.
2
0
01
01
3
E
EF
91
Press PAUSE button.
4
Check that a clear chart is
shot in larger size than nine
grids in the center of frame
shown on the screen.
5
E
EF
00
Press PAUSE button.
6
0
01
00
7
In the following adjustment,
if the “Center frame” is used,
adjust the clear chart to this
position.
A clear chart must be shot in larger size than central nine grids. 
Fig.6-1-8
8.
F No. & ND Light Quality Standard Data Input
RadarW
RadarW
RadarW
RadarW
RadarW
Correct the lens iris and the dispersion of the ND filter light quan-
tity.
Subject
Clear chart (Center frame)
Adjustment Page
F
Adjustment Address
1C to 23
Note 1:
Perform “Mechanical Shutter Adjustment” after this ad-
justment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) ZOOM .................................................................... WIDE end
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
2C
01
3
6
01
BB
Press PAUSE button. (Note 4)
4
6
02
Check the data changes to “01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 1C to 23.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
0
01
00
Page of 66
Display

Click on the first or last page to see other DCR-IP1 / DCR-IP1E (serv.man4) service manuals if exist.