DOWNLOAD Sony DCR-DVD403 / DCR-DVD403E / DCR-DVD803 / DCR-DVD803E (serv.man3) Service Manual ↓ Size: 1.04 MB | Pages: 82 in PDF or view online for FREE

Model
DCR-DVD403 DCR-DVD403E DCR-DVD803 DCR-DVD803E (serv.man3)
Pages
82
Size
1.04 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-dvd403-dcr-dvd403e-dcr-dvd803-dcr-dvd803e-sm3.pdf
Date

Sony DCR-DVD403 / DCR-DVD403E / DCR-DVD803 / DCR-DVD803E (serv.man3) Service Manual ▷ View online

6-49
DCR-DVD403/DVD403E/DVD803/DVD803E
1.
Diagnosis section
Use these buttons when diagnosing the drive block.
2.
Adjustment section
Use these buttons when adjusting the drive block.
3.
Comment display section
At the execution of diagnosis and adjustment, its progress situa-
tion is displayed.
1)
[Clear]
 button
This button clears the comment in the display section.
2)
[LOG]
 button
This button saves the comment in the display section as a log
file.
4.
Status display section
The result of diagnosis and adjustment is displayed.
5.
[SET]
 button (After completing the TEST)
This button cancels the TEST mode set to the cam coder during
the diagnosis and adjustment. If the TEST mode is cancelled suc-
cessfully, the following message is displayed.
Note:
Before exiting the AUDIT, be sure to cancel the TEST mode
by clicking the SET button of “After completing the TEST”.
Unless the TEST mode is cancelled, the drive may not op-
erate normally, such that “disc cover does not open”, “drive
error is displayed”, etc.
[Clear]
 button
[LOG]
 button
Fig. 6-2-8
Fig. 6-2-9
When OK
When NG
Fig. 6-2-10
6.
[STOP]
 button
This button stops the diagnosis and adjustment in the midway.
7.
Menu section
1)
[RESET]
 button
This button resets internal register.
(Use this button to interrupt the work so far when diagnosis
and adjustment stopped and no response is returned. The work
terminates with the previous adjustment data written to the
camcoder.)
2)
[Lid Open]
 button
This button opens the disc cover.
3)
[<DVD-R> Write Address]
 button
This button renews the setting of record address of the DVD-
R for Self Jitter Disc.
(Use this button when replacing the disc before the use limit
of DVD-R for Self Jitter Disc.)
8.
Caution display section
At the execution of POWER Adjustment, the caution of POWER
Adjustment is displayed.
Fig. 6-2-11
6-50
DCR-DVD403/DVD403E/DVD803/DVD803E
2-3-2.
Diagnosing Method
Order
1
2
3
4
Diagnostic item
Sensor
Operation
Click the 
[START]
 button of “DIAGNOSIS”.
Check the movement of the pickup lens (Fo-
cus direction/Tracking direction), and click
the 
[OK]
 button in the message window.
Set the DVD-R Reference Disc.
(At this time, when the Shock Sensor senses
a shock normally, this message disappears.)
Set the DVD-R Reference Disc, and then
close the disc cover and click the 
[OK]
 but-
ton in the message window.
Message
Disc
No Disc
No Disc
DVD-R
Reference Disc
2-3.
DIAGNOSIS
2-3-1.
Menu in Diagnosis Section
START button:
All items of diagnosis buttons are executed
in the descending order.
Diagnosis button:
Only the diagnostic item assigned to the
button name is executed.
Status lamp:
Diagnosis status is displayed with color.
White
Not diagnosed
Red blinking
Diagnosis in progress
Green
Diagnosis OK
Red
Diagnosis NG
START button
Status lamp
Diagnosis buttons
Fig. 6-2-12
6-51
DCR-DVD403/DVD403E/DVD803/DVD803E
Order
5
6
7
8
9
10
11
12
13
14
Diagnostic item
-R Seek
-R Read
-R Write
-RW Seek
-RW Read
-RW Write
+RW Seek
+RW Read
+RW Write
Operation
(If the diagnosis result of previous item is OK,
this item is executed successively.)
(If the diagnosis result of previous item is OK,
this item is executed successively.)
Remove the DVD-R Reference Disc, and set
the DVD-R for Self Jitter Disc, and then close
the disc cover and click the 
[OK]
 button in
the message window.
Remove the DVD-R for Self Jitter Disc, and
set the DVD-RW Reference Disc, and then
close the disc cover and click the 
[OK]
 but-
ton in the message window.
(If the diagnosis result of previous item is OK,
this item is executed successively.)
Remove the DVD-RW Reference Disc, and
set the DVD-RW DOW Disc, and then close
the disc cover and click the 
[OK]
 button in
the message window.
Remove the DVD-RW DOW Disc, and set
the DVD+RW Reference Disc, and then close
the disc cover and click the 
[OK] 
button in
the message window.
(If the diagnosis result of previous item is OK,
this item is executed successively.)
(If the diagnosis result of previous item is OK,
this item is executed successively.)
Remove the DVD+RW Reference Disc.
(On the AUDIT screen, if the status lamps of
respective diagnosis buttons are all lit in
green, the diagnosis is over.)
Message
Disc
DVD-R
Reference Disc
DVD-R
for Self Jitter Disc
DVD-RW
Reference Disc
DVD-RW
DOW Disc
DVD+RW
Reference Disc
No Disc
Note:
Before exiting the AUDIT, click the 
[SET]
 button of “After completing the TEST” to cancel the TEST mode.
6-52
DCR-DVD403/DVD403E/DVD803/DVD803E
2-4.
POWER ADJUSTMENT
In the POWER Adjustment, operate the drive with the disc cover left open. During the adjustment, be sure to observe the following
precautions:
1) Set the optical sensor disc correctly.
2) Keep the distance of more than 30 cm apart from the camcoder.
3) Work on the LCD screen side of the camcoder (opposite side of the drive).
2-4-1.
Menu in POWER Adjustment Section
START button:
All items of adjustment buttons are ex-
ecuted in the descending order.
Adjustment button:
Only the adjustment item assigned to the
button name is executed.
Status lamp:
Adjustment status is displayed with color.
White
Not adjusted
Red blinking
Adjustment in progress
Green
Adjustment OK
Red
Adjustment NG
START button
Status lamp
Adjustment buttons
Fig. 6-2-13
Page of 82