DOWNLOAD Sony CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 Service Manual ↓ Size: 16.83 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TRV107 CCD-TRV108 CCD-TRV308 CCD-TRV408 CCD-TRV608
Pages
127
Size
16.83 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
ccd-trv107-ccd-trv108-ccd-trv308-ccd-trv408-ccd-tr.pdf
Date

Sony CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 Service Manual ▷ View online

5-28
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
5-2. MECHANISM SECTION
ADJUSTMENT
Mechanism Section adjustments, checks, and replacement of
mechanism parts, refer to the separate volume “8mm Video
Mechanism Adjustment Manual IX   M2000 Mechanism ”.
2-1. ADJUSTMENT REMOTE COMMANDER
Connect the adjustment remote commander to CN713 of VC-272
board via I/F unit for LANC control (J-6082-521-A) and CPC jig
connector (J-6082-539-A). To operate the adjustment remote
commander, connect the AC power adapter (8.4Vdc) to the DC IN
jack of I/F unit for LANC control, or connect the L series Info-
LITHIUM battery to the battery terminal of I/F unit for LANC
control.
2-2. OPERATING WITHOUT  CASSETTE
1)
Refer to “Section 2. DISASSEMBLY” and supply the power
with the cabinet assembly removed. (So that the mechanical
deck can be operated.)
2)
Connect the adjustment remote commander.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Close the cassette compartment without loading a cassette and
complete loading.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: F, address: 20, set data: 01, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: D, address: 10, set data: 10, and press the PAUSE
button of the adjustment remote commander.
8)
Disconnect the power supply of the unit.
By carrying out the above procedure, the unit can be operated
without loading a cassette.
Be sure to carry out “Processing after Operations” after
checking the operations.
Set the data of page: D, address: 10 to the following if the
sensor ineffective mode, forced VTR power supply On mode
or forced camera power supply ON mode are to be used
together.
Forced VTR power ON mode ........................................ 12
Forced camera power ON mode .................................... 11
[Procedure after checking operations]
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 20, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Disconnect the power supply of the unit.
2-3. TAPE PATH ADJUSTMENT
1. Preparations for Adjustment
1)
Clean the tape path face (tape guide, capstan shaft, pinch roller).
2)
Connect the adjustment remote commander.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: F, address: 20, set data: 08, and press the PAUSE
button of the adjustment remote commander.
(Be sure to perform “Processing after operation” after
completing adjustments.)
6)
Connect the oscilloscope to I/F unit for LANC control.
Channel 1: PB RF (Pin 9 of CN713)
External trigger: SWP (Pin 5 of CN713)
7)
Playback the alignment tape for tracking. (WR5-1NP)
8)
Check that the oscilloscope RF waveform is normal at the
entrance and exit.
If not normal, adjust according to the separate volume “8mm
Video Mechanical Adjustment Manual IX M2000 Mechanism ”.
9)
Perform  “Processing after operations”, after completing
adjustment.
Test point of CPC jig for SB
Note:
Pin No. are those of CN713.
Table 5-2-1.
[Procedure after operations]
1)
Connect the adjustment remote commander, and turn on the
HOLD switch.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: F, address: 20, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Remove the power supply from the unit.
Fig. 5-2-1.
CH1
Entrance 
side
Exit side
Check this section
(Normal waveform)
CH2
(Trigger)
V
Pin No.
14
9
3
5
4
Signal Name
BL
EVF VG
PB RF (MON)
BPF MONI
TMS
TDI
SWP
CAP FG
Pin No.
15
6,8,10
7
2
Signal Name
EVF VCO
BL 4.75
GND
REC RF (RF IN)
TDO
TCK
IR VIDEO
Ver 1.2  2002. 07
5-29
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
5-3. VIDEO SECTION ADJUSTMENTS
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1. Equipment to Required
1)
TV monitor
2)
Oscilloscope (dual-phenomenon, band width above 30 MHz
with delay mode) (Unless specified otherwise, use a 10 : 1
probe.)
3)
Frequency counter
4)
Pattern generator with video output terminal
5)
Digital voltmeter
6)
Audio generator
7)
Audio level meter
8)
Audio distortion meter
9)
Audio attenuator
10) Regulated power supply
11) NTSC alignment tapes
• For tracking adjustment (WR5-1NP)
Parts code : 8-967-995-02
• For video frequency characteristics adjustment (WR5-7NE)
Parts code : 8-967-995-13
• For checking Standard 8 mode operations
For LP (WR5-4NL)
Parts code : 8-967-995-51
For SP (WR5-5NSP)
Parts code : 8-967-995-42
Note:
The following alignment tapes can also be used.
WR5-4NSP (8-967-995-41)
• For checking Hi8 mode operations
For LP (WR5-8NLE)
Parts code : 8-967-995-52
For SP (WR5-8NSE)
Parts code : 8-967-995-43
• For BPF adjustment (WR5-11NS)
Parts code : 8-967-995-71
13) Adjustment remote commander (J-6082-053-B)
14) CPC jig connector (J-6082-539-A)
15) I/F unit for LANC control (J-6082-521-A)
Ver 1.2  2002. 07
5-30
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
3-1-2.
Precautions on Adjusting
1)
Connect the adjustment remote commander to CN713 of VC-
272 board via I/F unit for LANC control (J-6082-521-A) and
CPC jig connector (J-6082-539-A). To operate the adjustment
remote commander, connect the AC power adapter to the DC
IN jack of I/F unit for LANC control, or connect the L series
Info-LITHIUM battery to the battery terminal of I/F unit for
LANC control.
2)
The adjustments of this unit are performed in the VTR mode
or camera mode.
To set to the VTR mode, set the power switch to “PLAYER” or
set the “Forced VTR Power ON mode” using the adjustment
remote commander (Note1).
To set to the Camera mode, set the power switch to “CAMERA”
or set the “Forced Camera Power ON mode” using the
adjustment remote commander (Note2).
After completing adjustments, be sure to exit the “Forced VTR
Power ON Mode” or “Forced Camera Power ON Mode”.
(Note3)
3)
The front panel block (SI-033 board, microphone unit, video
light) need not be connected. To remove, disconnect the
following connector.
SI-033 board CN752 (16P 0.5mm)
4)
As removing the cabinet (R) assembly (removing CN709 of
the VC-272 board) means removing the lithium 3V power
supply (CF-2000 block BT001), data such as date, time, user-
set menus will be lost. After completing adjustments, reset these
data. If the cabinet (R) assembly has been removed, the self-
diagnosis data, data on history of use (total drum rotation time
etc.) will be lost. Before removing, note down the self-diagnosis
data (data of page: 2, address: B0 to C6) and the data on history
use (data of page: 2, address: A2 to AA and E0 to E2). (Refer
to “5-4.Service Mode”.)
5)
The cabinet (R) assembly (CF-2000 block, LCD block) need
not be connected to operate the VTR block. When removing
the cabinet (R) assembly, disconnect the following connectors.
(Note4)
1. VC-272 board CN709 (22P, 0.5mm)
2. VC-272 board CN701 (20P, 0.8mm)
6)
The lens block (CD-354 board) need not be connected. To
remove, disconnect the following connectors.
1. VC-272 board CN271 (14P, 0.5mm)
2. VC-272 board CN301 (24P, 0.5mm)
7)
The EVF block (VF-150 board) need not be connected. To
remove, disconnect the following connectors.
VC-272 board CN705 (20P, 0.5mm)
8)
The USB connector need not be connected. To remove,
disconnect the following connectors. (CCD-TRV608)
VC-272 board CN715 (6P, 0.5mm)
9)
By setting the “Forced VTR Power ON mode” or “Forced
Camera Power ON mode”, the video section can be operate
even if the control switch block (SS-2000) has been removed.
When removing the control switch block (SS-2000), disconnect
the following connector.
VC-272 board CN711 (5P 0.8mm)
Note1:
Setting the “Forced VTR Power ON” mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button.
The above procedure will enable the VTR power to be turned on
with the control switch block (SS-2000) removed.
After completing adjustments, be sure to exit the “Forced VTR
Power ON mode”.
Note2:
Setting the “Forced Camera Power ON” mode (Camera mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button.
The above procedure will enable the camera power to be turned
on with the control switch block (SS-2000) removed.
After completing adjustments, be sure to exit the “Forced Camera
Power ON mode”.
Note3:
Exiting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
3) Select page: 0, address: 01, and set data: 00.
Note4:
When the FK-2000 block or the CF-2000 block is removed, the
VTR does an unusual movement for one minute after the power is
turned on. So, operate the VTR by the adjustment remote
commander (with the HOLD switch set in the OFF position) after
it passes for more than one minute.
Ver 1.2  2002. 07
5-31
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
3-1-3.
Adjusting Connectors
Some of the adjusting points of the video section are concentrated
in CN713 of VC-272 board. Connect the Measuring instrument and
the adjustment remote commander via the I/F unit for LANC control
(J-6082-521-A) and CPC jig connector (J-6082-539-A) to CN713.
To operate the adjustment remote commander, connect the AC power
adapter to the DC IN jack of I/F unit for LANC control, or connect
the L series Info-LITHIUM battery to the battery terminal of I/F
unit for LANC control.
The following table shows the Pin No. and signal name of CN713.
Table 5-3-1.
The following table shows the arrangement of the test points of I/F
unit for LANC control. (Pin No. are those of CN713.)
Table 5-3-2.
3-1-4.
Connecting the Equipment
Connect the measuring instruments as shown in Fig. 5-3-2 and
perform the adjustments.
Fig. 5-3-2.
Adjustment
remote
commander
LANC jack
Main unit
A/V OUT jack
TV monitor
VIDEO
(Yellow)
AUDIO (Black)
Pin No.
1
2
3
4
5
6
7
8
Signal Name
N.C.
IR VIDEO
BPF MONI
CAP FG
RF SWP
REG GND
REC RF
REG GND
Pin No.
9
10
11
12
13
14
15
16
Signal Name
PB RF
REG GND
LANC OUT
LANC IN
XLANC POWER ON
EVF VG
VCO
N.C.
Pin No.
14
9
3
5
4
Signal Name
BL
EVF VG
PB RF (MON)
BPF MONI
TMS
TDI
SWP
CAP FG
Pin No.
15
6,8,10
7
2
Signal Name
EVF VCO
BL 4.75
GND
REC RF (RF IN)
TDO
TCK
IR VIDEO
Fig. 5-3-1.
CPC jig connector
CPC jig
Remove the CPC lid
CN713
Conductor side
16
1
Ver 1.2  2002. 07
Page of 127
Display

Sony CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 Service Manual ▷ Download