DOWNLOAD Sony CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 Service Manual ↓ Size: 16.83 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TRV107 CCD-TRV108 CCD-TRV308 CCD-TRV408 CCD-TRV608
Pages
127
Size
16.83 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
ccd-trv107-ccd-trv108-ccd-trv308-ccd-trv408-ccd-tr.pdf
Date

Sony CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 Service Manual ▷ View online

5-24
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
1-5.
LCD SYSTEM ADJUSTMENT
Note 1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note 3:
Set the LCD BRIGHT (Menu display) to the center.
Set the LCD COLOR (Menu display) to the center.
Note 4:
Connect the adjustment remote commander to CN713 of VC-272
board via I/F unit for LANC control (J-6082-521-A) and CPC jig
connector (J-6082-539-A). To operate the adjustment remote
commander, connect the AC power adapter (8.4Vdc) to the DC
IN jack of I/F unit for LANC control, or connect the L series Info-
LITHIUM battery to the battery terminal of I/F unit for LANC
control.
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN5502 of the PD-156 board. Connect the
measuring instruments via the multi CPC jig (J-6082-311-A). The
following table shows the Pin No. and signal name of CN5502.
Table 5-1-8.
1. LCD Type  Check
By measuring the resistor value between Pin 6 of CN5502 and
GND, the type of LCD can be discriminated.
Table 5-1-9.
Pin No.
1
3
5
7
9
Signal Name
VB
VG
VR
C-SYNC/XHD
GND
Pin No.
2
4
6
8
10
Signal Name
XVD OUT
PANEL COM
PANEL ID
XHD OUT
GND
Resistor
value
1.0 k
4.7 k
LCD type
2.5 LCD TYPE S (61k)
3.0 LCD TYPE S (123k)
CCD-
TRV107/TRV108/
TRV308/TRV408
TRV608
PD-156 board
10
9
1
2
CN5502
Ver 1.2  2002. 07
5-25
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
2. VCO Adjustment (PD-156 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 8 of CN5502 (XHD OUT)
Measuring Instrument
Frequency counter
Adjustment Page
7
Adjustment Address
43
Specified Value
f = 15734 ± 30Hz
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
43
Change the data and set the VCO
frequency (f) to the specified value.
3
7
43
Press PAUSE button.
4
0
01
00
Set the data.
3. RGB AMP Adjustment (PD-156 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 3 of CN5502 (VG)
External trigger: Pin 4 of CN5502
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
7
Adjustment Address
46
Specified Value
A = 3.62 ± 0.05V
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
46
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to the
specified value.
(The data should be “00” to “3F”.)
3
7
46
Press PAUSE button.
4
0
01
00
Set the data.
Fig. 5-1-16.
Pedestal
Pedestal
A
2H
5-26
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
4. Contrast Adjustment (PD-156 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 3 of CN5502 (VG)
External trigger: Pin 4 of CN5502
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
7
Adjustment Address
4B
Specified Value
2.5 LCD: A = 3.52 ± 0.07V
3.0 LCD: A = 3.32 ± 0.07V
Note: 2.5 LCD model : CCD-TRV107/TRV108/TRV308/TRV408
3.0 LCD model : CCD-TRV608
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
4B
Change the data and set the
voltage (A) between the 100 IRE
and 0 IRE (pedestal) to the
specified value.
(The data should be “00” to “7F”.)
3
7
4B
Press PAUSE button.
4
0
01
00
Set the data.
5. COM AMP Adjustment (PD-156 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 4 of CN5502 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
7
Adjustment Address
48
Specified Value
2.5 LCD: A = 6.30 ± 0.05V
3.0 LCD: A = 6.05 ± 0.05V
Note: 2.5 LCD model : CCD-TRV107/TRV108/TRV308/TRV408
3.0 LCD model : CCD-TRV608
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
48
Change the data and set the
PANEL COM signal level (A) to
the specified value.
3
7
48
Press PAUSE button.
4
0
01
00
Set the data.
Fig. 5-1-17.
100 IRE
Pedestal
A
2H
Fig. 5-1-18.
A
2H
5-27
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
6. V-COM Adjustment (PD-156 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
7
Adjustment Address
45
Specified Value
The brightness difference between the
section A and section B is minimum.
Note: This adjustment should be carried out upon completion of the
following adjustments.
RGB AMP Adjustment
Contrast Adjustment
COM AMP Adjustment
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
45
Change the data so that the
brightness of the section A and
that of the section B is equal.
3
7
45
Subtract 8 from the data.
4
7
45
Press PAUSE button.
5
0
01
00
Set the data.
7. White Balance Adjustment (PD-156 board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
7
Adjustment Address
49, 4A
Specified Value
The LCD screen should not be colored.
Note: Check the white balance only when replacing the following parts. If
necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5501
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
49
60
Set the data, and press PAUSE
button.
3
7
4A
65
Set the data, and press PAUSE
button.
4
7
49
Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5
7
49
Change the data so that the LCD
screen is not colored.
6
7
49
Press PAUSE button.
7
7
4A
Change the data so that the LCD
screen is not colored.
8
7
4A
Press PAUSE button.
9
7
4A
If the LCD screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
Fig. 5-1-19.
A
A
A
A
B
B
B
B
Page of 127
Display