Sony CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 Service Manual ▷ View online

5-8
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
1-2.
INITIALIZATION OF D, E, F, 7 PAGE DATA
1. Initializing the D, E, F, 7 Page Data
Note1: If “Initializing the D, E, F, 7 Page Data” is performed, all
data of the D page, E page, F page and 7 page will be
initialized. (It is impossible to initialize a single page.)
Note2: If the D, E, F, 7 page data has been initialized, “Modification of D,
E, F, 7 Page Data” and all adjustments need to be performed again.
Adjusting page
D
Adjusting Address
10 to 7F
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to 6B
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
00
55
Set the data.
3
6
01
55
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”.
5
2
00
29
Set the data
6
2
01
29
Set the data, and press the PAUSE
button.
7
Perform “Modification of D, E, F,
7 Page Data”.
2. Modification of D, E, F, 7 Page Data
If the D, E, F, 7 page data has been initialized, change the data of
the “Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D, E, F, 7 Page
data
Order Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press the PAUSE
button.
Note: If the following symptoms occur after completing of the
“Modification of D, E, F, 7 page data”, check that the data of the
“Fixed data-2” addresses of D page are same as those of the same
model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD or viewfinder
screen is flashing.
2) The power is shut off so that unit cannot operate.
3. D Page Table
Note1: Fixed data-1: Initialized data. (Refer to “1. Initializing the D, E, F,
7 Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of D, E, F,
7 Page Data”.)
00 to 0F
10
11 to 12
13
14 to 19
1A
1B to 1E
1F
20 to 21
22
23
24
25 to 26
27
28 to 31
32
33
34
35
36
37
38
39
3A to 3B
3C
3D
3E to 40
41
42
43
44
45
46
47
48
49
4A
4B
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Address
Remark
Initial data
5-9
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
4C
4D
4E
4F
50
51 to 54
55
56 to 57
58
59
5A
5B
5C
5D to 5E
5F
60 to 72
73
74 to 7B
7C
7D to 7F
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Table. 5-1-2.
Initial data
4. F Page table
Note1: Fixed data-1: Initialized data. (Refer to “1. Initializing the D, E, F,
7 Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of D, E, F,
7 Page Data”.)
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E to 21
22
23
24
25 to 2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C to 3E
3F
40
41
42 to 44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
00
00
00
00
00
00
00
00
00
00
00
00
52
89
88
80
7A
2B
80
65
80
8D
87
33
34
8C
28
07
3A
4A
12
0B
54
00
19
00
37
00
00
Emergency memory address
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
HALL adj.
Fixed data-2
AWB & LV standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
28MHz origin osc. Adj.
Flange back adj.
Address
Remark
Initial data
D page
5-10
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60 to 61
62
63
64 to 68
69
6A to 72
73
74
75
76
77 to 85
86
87 to 93
94
95
96 to AB
AC
AD to AE
AF
B0
B1
B2
B3 to B5
B6
B7
B8
B9 to C9
CA
CB
CC
CD
CE to DD
DE
DF
E0
E1
E2
E3
E4 to E8
E9
EA
EB
EC
ED
EE
EF to F1
F2
F3
F4 to FF
04
00
00
00
83
0B
00
50
68
62
B4
B4
A0
A6
80
FD
F4
0F
31
Flange back adj.
Fixed data-2
Flange back adj.
CAP FG offset adj.
Switching position adj.
Fixed data-1
AFC fo adj.
Y OUT level adj.
C OUT level adj.
Fixed data-1
REC Y current adj.
Fixed data-1
REC C/AFM current adj.
Fixed data-1
1.5MHz deviation adj.
BPF fo adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Color reproduction adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial data
Address
Remark
Initial data
Table. 5-1-3.
F page
5-11
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
Address
Remark
00 to 01
02
03 to 06
07
08 to 09
0A
0B
0C
0D
0E to 0F
10
11 to 15
16
17 to 1E
1F
20 to 25
26
27 to 39
3A
3B to 40
41
42
43
44
45
46 to 50
51
52
53
54
55 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
00 to 22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E to 30
31
32
33
34
35
36
37 to 39
3A
3B to 40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E to 53
54
55
56 to 6B
A0
2F
71
8A
2E
AD
60
65
50
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
RGB AMP adj. (EVF) *1
Fixed data-1
Contrast adj. (EVF)  *1
Fixed data-1
Fixed data-2
VCO adj. (LCD)
Fixed data-1
V COM adj. (LCD)
RGB AMP adj. (LCD)
Fixed data-1
COM AMP adj.(LCD)
White balance adj.(LCD)
Contrast adj.(LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial data
5. E Page Table
Note: Fixed data-1: Initialized data. (Refer to “1. Initializing the D, E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of D, E, F, 7
Page Data”.)
Table. 5-1-4
6. 7 Page Table
Note: Fixed data-1: Initialized data. (Refer to “1. Initializing the D, E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of D, E, F, 7
Page Data”.)
*1: EVF TYPE S model (CCD-TRV107/TRV308/TRV408/
TRV608)
Table. 5-1-5.
Page of 127
Display

Click on the first or last page to see other CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 service manuals if exist.