Sony CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 Service Manual ▷ View online

5-16
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
6. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment frame)
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
3F, 41, AF, B0
Specified Value
All color luminance points should settle
within each color reproduction frame.
Note: CCD TYPE S model: CCD-TRV107/TRV108/TRV608
CCD TYPE M model: CCD-TRV308/TRV408
Switch setting:
1)
NIGHT SHOT (Lens block) ............................................ OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
LIGHT (FK-2000 block) .................................................. OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 77, and write down the data.
3)
Select page: F, address: 77, set data: 29 and press the PAUSE
button.
4)
Select page: F, address: 2B, set data: 17 and press the PAUSE
button.
5)
Select page: 6, address: 01, set data: 3D, and press the PAUSE
button.
6)
Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
7)
Change the data of page: F, address: 3F, 41, AF and B0, settle
each color luminance point in each color reproduction frame.
Note: Be sure to press the PAUSE button of the adjustment remote
commander before changing the addresses. If not, the new data
will not be written to the memory.
Processing after Completing Adjustments:
1)
Select page: F, address: 77, set the data written down at step 2),
and press the PAUSE button.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
3)
Select page: 0, address: 01, and set data: 00.
Burst position
For CCD TYPE S
Burst position
For CCD TYPE M
Fig. 5-1-11.
5-17
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
7. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
34 to 39
Note1: This adjustment should be carried out upon completion of “Color
reproduction adjustments”.
Note2: After the power is turned on, this adjustment can be done only
once.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
NIGHT SHOT (Lens block) ............................................ OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
LIGHT (FK-2000 block) .................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Wait for 2 sec.
3
6
01
11
Set the data, and press PAUSE
button.
4
6
01
0D
Set the data, and press PAUSE
button
5
6
02
Check that the data changes to
“01”. (Note4)
Note4: The adjustment data will be automatically input to page: F, address:
34 to 39.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Perform “Auto White Balance
Adjustment”.
5-18
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
8. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
3A, 3B
Specified Value
1/6 CCD TYPE S model:
R ratio: 2B80 to 2C80
B ratio: 5E00 to 5F00
1/4 CCD TYPE S model:
R ratio: 2A80 to 2B80
B ratio: 6100 to 6200
1/4 CCD TYPE M model:
R ratio: 2B00 to 2C00
B ratio: 6100 to 6200
Note1: 1/6 CCD TYPE S model: CCD-TRV107/TRV108
1/4 CCD TYPE S model: CCD-TRV608
1/4 CCD TYPE M model: CCD-TRV308/ TRV408
Note2: After the power is turned on, this adjustment can be done only
once.
Note3: Perform “Auto White Balance & LV Standard Data Input” before
this adjustment.
Note4: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
NIGHT SHOT (Lens block) ............................................ OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
LIGHT (FK-2000 block) .................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
0
01
01
Set the data.
3
F
90
Write down the data.
4
F
90
Set the following data, and press
PAUSE button.
2C: 1/6 CCD TYPE S model
2B: 1/4 CCD TYPE S model
2B: 1/4 CCD TYPE M model
5
F
91
Write down the data.
6
F
91
Set the following data, and press
PAUSE button.
00: 1/6 CCD TYPE S model
00: 1/4 CCD TYPE S model
80: 1/4 CCD TYPE M model
7
F
92
Write down the data.
8
F
92
Set the following data, and press
PAUSE button.
5E: 1/6 CCD TYPE S model
61: 1/4 CCD TYPE S model
61: 1/4 CCD TYPE M model
9
F
93
Write down the data.
10
F
93
80
Set the data, and press PAUSE
button.
11
6
01
A7
Set the data, and press PAUSE
button.
12
Wait for 2 sec.
13
6
01
A5
Set the data, and press PAUSE
button.
14
6
02
Check that the data changes to
“01”. (Note5)
15
6
01
3F
Set the data, and press PAUSE
button.
16
0
03
04
Set the data.
17
1
Check that the display data (Note4)
satisfies the R ratio specified value.
18
0
03
05
Set the data.
19
1
Check that the display data (Note4)
satisfies the B ratio specified value.
Note5: The adjustment data will be automatically input to page: F, address:
3A, 3B.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
F
90
Set the data that is written down
at step 3, and press PAUSE button.
3
F
91
Set the data that is written down
at step 5, and press PAUSE button.
4
F
92
Set the data that is written down
at step 7, and press PAUSE button.
5
F
93
Set the data that is written down
at step 9, and press PAUSE button.
6
0
03
00
Set the data.
7
0
01
00
Set the data.
5-19
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
9. White Balance Check
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Specified Value
Fig. 5-1-12. A to B
Switch setting:
1)
NIGHT SHOT (Lens block) ............................................ OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
LIGHT (FK-2000 block) .................................................. OFF
Checking method:
Order Page Address Data
Procedure
Indoor white balance check
1
Check that the lens is not covered
with either filter.
2
6
01
0F
Set the data, and press PAUSE
button.
3
Check that the center of the white
luminance point is within the
circle shown Fig. 5-1-12. A.
4
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
5
6
01
3F
Set the data, and press PAUSE
button.
6
Place the C14 filter on the lens.
7
Check that the center of the
white luminance point is within
the circle shown Fig. 5-1-12. B.
8
Remove the C14 filter.
LV data check
9
Place the ND filter 1.5 (1.0 + 0.1
+ 0.4) on the lens.
10
6
01
0F
Set the data, and press PAUSE
button.
11
Wait for 2 sec.
12
0
03
06
Set the data.
13
1
Check that the display data (Note)
satisfies the specified value.
   Specified value: 0000 to 0BC0
Note: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
03
00
Set the data.
R-Y
B-Y
1.5mm
3mm
3mm
Fig. 5-1-12. (A)
Fig. 5-1-12. (B)
R-Y
2mm
B-Y
2mm
Page of 127
Display

Click on the first or last page to see other CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 service manuals if exist.