Sony SAL85F28 Service Manual ▷ View online
4-7
SAL85F28 (2.8/85 SAM) (85mm F2.8 SAM)
4-5. FOCUSING ERROR AMOUNT CHECK
Shoot images with the lens to be tested and the AE master lens under the following conditions (Note 1), and compare the images to check
the error amount (Note 2).
Note 1:
the error amount (Note 2).
Note 1:
・
Shooting magnification (60, 40, 20 times)
・
Chart for checking the depth area of image-formation (tilting chart 2 types)
・
Defocus value 0
±
10
μ
m
Note 2:
The higher the magnification, the focusing error amount becomes the bigger. Therefore, it is easy to judge of result.
If the error amount is outside of the range, perform 4-7-4. Focusing Error Amount Adjustment (Write
⊿
SB) .
Equipment
Chart for checking the depth area of image-formation (40, 60 times)
Acquire the Chart_for_checking_image_formation_40x_60x_(E).zip from the each HQ.
Acquire the Chart_for_checking_image_formation_40x_60x_(E).zip from the each HQ.
Chart for checking the depth area of image-formation (20 times)
Acquire the Chart_for_checking_image_formation_20x_(E).zip from the each HQ.
Acquire the Chart_for_checking_image_formation_20x_(E).zip from the each HQ.
Software
Acquire the following either software from the each HQ.
Acquire the following either software from the each HQ.
Software
Camera
DSLR-A700 Defocus checker
DSLR-A700
Defocus Checker 2
SLT-A37/A57/A58/A65/A77/A99
Table 4-5-1
Camera (One of DSLR-A700, SLT-A37/A57/A58/A65/A77/A99)
HASP key
Personal Computer (supporting Seus-EX)
AE Master Lens
J-6082-597-A: 50 mm/F1.7
Illumination
J-6082-642-A: Fluorescent Lamp (specified color rendering)
J-6082-643-A: Fluorescent Light Stand (high-frequency lighting type)
Memory Card
Tripod
HASP key
Personal Computer (supporting Seus-EX)
AE Master Lens
J-6082-597-A: 50 mm/F1.7
Illumination
J-6082-642-A: Fluorescent Lamp (specified color rendering)
J-6082-643-A: Fluorescent Light Stand (high-frequency lighting type)
Memory Card
Tripod
1. Preparation
1) Insert the memory card to the camera.
2) Set the camera and chart for checking the depth area of image-formation as shown in Table 4-5-2, Fig. 4-5-1 and Fig. 4-5-2.
1) Insert the memory card to the camera.
2) Set the camera and chart for checking the depth area of image-formation as shown in Table 4-5-2, Fig. 4-5-1 and Fig. 4-5-2.
Note 1:
Shooting distance is obtained by shooting magnification and focal length as following.
[Shooting distance] = [shooting magnification]
×
[focal length]
Note 2:
Select the combination according to the Table 4-5-2 Guidelines table.
Note 3:
If the shooting distance using a 60 times chart cannot be ensured indoors, temporarily use a combination of 40 times chart or 20 times chart.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
3) Connect the camera and personal computer (when using HASP Key) with USB cable and activate Defocus Checker 2 or DSLR-A700
Defocus checker.
In case Defocus Checker 2 is used, click [Connect] to set connection mode.
Note:
Note:
If an abnormal phenomenon appears during installation of the teleconverter used by the user, install the user s teleconverter.
Guidelines Table
Selection of
Shooting magni-
fication
Shooting magni-
fication
AF Assist Chart (Size)
Refer to Fig. 4-5-1.
Refer to Fig. 4-5-1.
Applicable Cam-
era (image sensor
type)
era (image sensor
type)
Applicable Lens
Calculation example of shoot-
ing distance
[shooting magnification]
ing distance
[shooting magnification]
×
[focal length] = [shooting dis-
tance]
tance]
60 times
(middle distance)
(middle distance)
AF Assist Chart 60 Times
(200 mm
(200 mm
×
100 mm)
APS-C size type
All
60 times
×
50 mm = 3000 mm
40 times
(middle distance)
(middle distance)
AF Assist Chart 40 Times
(132 mm
(132 mm
×
66 mm)
35 mm full size type
All
40 times
×
50 mm = 2000 mm
20 times
(short distance)
(short distance)
AF Assist Chart 20 Times
(66 mm
(66 mm
×
33 mm)
both size available
Macro lens
Lens with a focal
length of more
than 300 mm
Lens with a focal
length of more
than 300 mm
•
•
•
20 times
×
300 mm = 6000 mm
Table
4-5-2
(100 mm)
(66 mm)
(33 mm)
(200 mm)
(132 mm)
(66 mm)
AF Assist Chart
60 Times
60 Times
AF Assist Chart
40 Times
40 Times
AF Assist Chart
20 Times
20 Times
Fig.
4-5-1
Camera Setting
Exposure mode
Focus Mode
Focus Area
Focus Mode
Focus Area
Image Size
Super SteadyShot
Drive Mode
Super SteadyShot
Drive Mode
: A (Open Aperture)
: MF
: Spot Focus Area
(Fixed at the center)
: L
: OFF
: Self-timer
: MF
: Spot Focus Area
(Fixed at the center)
: L
: OFF
: Self-timer
Shooting distance
Set the optical axis to the center
of the AF assist chart.
of the AF assist chart.
AF Assist Chart
(60 Times/40 Times)
(60 Times/40 Times)
Chart for checking the depth area of image-formation
(60 Times/40 Times)
(60 Times/40 Times)
Fig.
4-5-2
4-8
SAL85F28 (2.8/85 SAM) (85mm F2.8 SAM)
2. Shooting procedure
1) Click the [Start] of Defocus Checker 2 or DSLR-A700 Defocus checker to start the measurements.
2) Adjust defocus value to obtain 0
1) Click the [Start] of Defocus Checker 2 or DSLR-A700 Defocus checker to start the measurements.
2) Adjust defocus value to obtain 0
μ
m in the manual focus mode.
The tolerance is 0
±
10
μ
m . (Fig. 4-5-3)
3) Click the [Stop] of Defocus Checker 2 or DSLR-A700 Defocus checker.
4) Shoot an image by self-timer.
5) Perform the steps 1) to 4) by using the AE master lens and the lens to be tested.
4) Shoot an image by self-timer.
5) Perform the steps 1) to 4) by using the AE master lens and the lens to be tested.
Note 1:
Shoot images with the AE master lens and the lens to be tested using the same camera.
Note 2:
Perform entire work within 10 minutes because values become unstable as the camera temperature increases.
If the work continues for 10 minutes or longer, cool down the camera and then restart the work.
Note 3:
Since focusing error amount increases in shooting images at a middle or long distance, comprehensive focusing error amount cannot be
determined correctly only by results with short-distance setting. If the shooting distance using a 60 times chart cannot be ensured indoors,
take either of the following methods.
determined correctly only by results with short-distance setting. If the shooting distance using a 60 times chart cannot be ensured indoors,
take either of the following methods.
Method 1
Use 35 mm full size type camera (SLT-A99) and 40 times chart. (When using the 40 times chart, shooting distance can shorten to 2/3 of 60
times chart.)
times chart.)
Method 2
Check the focusing error amount of short distance using 20 times chart temporarily. After that, shoot the something images outdoors in the
middle distance for using 60 times chart, and then check the focusing amount of middle distance.
middle distance for using 60 times chart, and then check the focusing amount of middle distance.
Defocus Checker 2
(For SLT-A37/A57/A58/A65/A77/A99)
(For SLT-A37/A57/A58/A65/A77/A99)
DSLR-A700 Defocus checker
(For DSLR-A700)
(For DSLR-A700)
In case Good (0
± less than 10 μm), frame
of waveform area displays in green.
In case Good (0
± less than 10 μm), frame
of waveform area and defocus value display
in green.
in green.
Fig.
4-5-3
3. The focusing error amount check
1) Open the images shot with the lens to be tested and the AE master lens by the image display software on the PC. (Display the images at
1) Open the images shot with the lens to be tested and the AE master lens by the image display software on the PC. (Display the images at
the same pixel magnification.)
2) Check the displacement between the focus position (peak of image-formation) of the lens to be tested and the focus position of the AE
master lens. (Refer to Fig. 4-5-4 and Fig. 4-5-5.)
3) Compare the error amount in step 2) with the reference value of Table 4-5-3 and check whether the error amount is within the accept-
able range. If the error amount is outside of the range, perform 4-7-4. Focusing Error Amount Adjustment (Write
⊿
SB) .
Reference value
Focal length/
85 mm
Distance
(mm)
1.7 m (20 times)
0
±
18
3.4 m (40 times)
0
±
74
5.1 m (60 times)
0
±
166
Table
4-5-3
<For reference 1: shooting image by AE master lens> (Fig. 4-5-4)
Assume it standard image in the setting environment.
If the peak of image-formation is to equal distance with AF assist chart position, it is ideal. In actual fact, the image of before and
behind the peak is displayed. (Because the environment, the individual difference of camera and lens conditions are combined.)
The image of before and behind the peak, assume it reference standard image.
When shooting the image with sharpness setting of the camera to + side, it is easy to distinguish the peak of imaging area remarkably.
If the peak of image-formation is to equal distance with AF assist chart position, it is ideal. In actual fact, the image of before and
behind the peak is displayed. (Because the environment, the individual difference of camera and lens conditions are combined.)
The image of before and behind the peak, assume it reference standard image.
When shooting the image with sharpness setting of the camera to + side, it is easy to distinguish the peak of imaging area remarkably.
Enlargement of same pixel magnification
Example of image shot with
a certain AE master lens under
a certain environment.
a certain AE master lens under
a certain environment.
Identifying the peak position of
image-formation:
• Center of sharpest area
• Center of area with less color fogged
- Front defocus area: Magenta fogged
- Rear defocus area: Green fogged
image-formation:
• Center of sharpest area
• Center of area with less color fogged
- Front defocus area: Magenta fogged
- Rear defocus area: Green fogged
Example where peak position accidentally matches
the AF Assist Chart position
the AF Assist Chart position
Fig.
4-5-4
•
•
•
•
•
•
4-9
SAL85F28 (2.8/85 SAM) (85mm F2.8 SAM)
<For reference 2: The example of focusing error amount value check> (Fig. 4-5-5)
Check the displacement between the focus position (peak of image-formation) of the lens to be tested and the focus position (peak of im-
age-formation) of the AE master lens.
Check the displacement between the focus position (peak of image-formation) of the lens to be tested and the focus position (peak of im-
age-formation) of the AE master lens.
Example of image shot with lens to be tested (50 mm F1.4)
Example of image shot with AE master lens
Peak area
(existing around 7 to 8 cm
of the rear scale)
(existing around 7 to 8 cm
of the rear scale)
Peak area
(existing around 6 to 7 cm
of the front scale)
(existing around 6 to 7 cm
of the front scale)
Error amount = approx. 14 cm
Fig.
4-5-5
Example of decision:
The lens to be tested has a tendency of backward defocusing compared to the AE master lens. The error amount is approx. 14 cm.
Compare this error amount with the reference value and check whether the error amount is within the acceptable range.
If the error amount is outside the acceptable range, perform 4-7-4. Focusing Error Amount Adjustment (Write
The lens to be tested has a tendency of backward defocusing compared to the AE master lens. The error amount is approx. 14 cm.
Compare this error amount with the reference value and check whether the error amount is within the acceptable range.
If the error amount is outside the acceptable range, perform 4-7-4. Focusing Error Amount Adjustment (Write
⊿
SB) .
4-1-2. Adjustment Flow Chart
4-6. INSTALLATION OF LENS ADJUSTMENT PROGRAM
4-6-1. Installing the Lens Adjustment Program (ActuatorCheckerSAM)
Equipment used
Personal Computer
Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
Finished Inspection JIG II (AC 100 - 240 V)
Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
Finished Inspection JIG II (AC 100 - 240 V)
Note 1:
Personal computer must have the condition that Windows Vista/7 runs normally and USB is connectable.
Note 2:
Acquire the Lens Adjustment Program (ACSAM-S-VerX.XX.zip) from the each HQ.
1. Saving Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
1) Unzip the Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
2) Save ACSAM-S-VerX.XX.exe in an arbitrary folder.
1) Unzip the Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
2) Save ACSAM-S-VerX.XX.exe in an arbitrary folder.
Note:
The version of ACSAM-S-VerX.XX.exe might be updated.
4-6-2. Connection of Finished Inspection JIGⅡ and Startup of Lens Adjustment Program (ActuatorCheck-
erSAM)
Note 1:
Confirm that 4-6-1. Installing the Lens Adjustment Program (ActuatorCheckerSAM) has been completed before this procedure is executed.
Note 2:
In case of performing Finished inspection, be sure to perform in the condition that the lens is laid down (do not perform in the lens standing con-
dition).
Equipment
Personal Computer
Finished Inspection JIG II (AC 100 - 240 V)
Note:
Finished Inspection JIG II (AC 100 - 240 V)
Note:
The cables and so on are not supplied as accessories.
AC Cable (Sold on the Market)
RS232C Cable (D-Sub 9 Pins (Male with Securing Screws), D-Sub 9 Pins (Female with Securing Screws)) Straight Type (Sold on the
Market)
USB to Serial Cable (D-Sub 9 Pins (Male)) (Sold on the Market)
M-BOX-JIG (J-6082-722-A) (Or the Jig supplied with Finished Inspection JIG (J-6082-645-A))
Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
RS232C Cable (D-Sub 9 Pins (Male with Securing Screws), D-Sub 9 Pins (Female with Securing Screws)) Straight Type (Sold on the
Market)
USB to Serial Cable (D-Sub 9 Pins (Male)) (Sold on the Market)
M-BOX-JIG (J-6082-722-A) (Or the Jig supplied with Finished Inspection JIG (J-6082-645-A))
Lens Adjustment Program (ACSAM-S-VerX.XX.zip)
1. Connection
Connect equipment and checking lens as shown in Fig. 4-6-1.
Note:
Note:
ActuatorCheckerSAM cannot start up without the connection to the finished inspection JIG II.
Final
Finished Inspection JIG II
AC Cable
D-sub 9 Pins: Male
D-sub 9 Pins: Female
RS232C Cable
USB to Serial Cable
Lens
Fig.
4-6-1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
4-10
SAL85F28 (2.8/85 SAM) (85mm F2.8 SAM)
2. Startup of Lens Adjustment Program (ActuatorCheckerSAM)
1) Turn on the personal computer and the finished inspection JIG II.
2) Start up ACSAM-S-VerX.XX.exe from an arbitrary folder.
1) Turn on the personal computer and the finished inspection JIG II.
2) Start up ACSAM-S-VerX.XX.exe from an arbitrary folder.
Note:
At the first time using, the followings appear on the screen (Fig. 4-6-2).
It is required to ask HQ about the password for the Com/User Characteristic Number and the manufacturer/type name of the personal
computer.
Ex. Com/User Characteristic Number : iYdDZfq9q
It is required to ask HQ about the password for the Com/User Characteristic Number and the manufacturer/type name of the personal
computer.
Ex. Com/User Characteristic Number : iYdDZfq9q
Personal Computer :
SONY PCV-RZ33P
It is no need to input password to the computer once registered.
(The screen requires password does not appear.)
If the personal computer or the finished inspection JIG II is changed, the password and the Com/User Characteristic Number are
changed. Therefore on the startup, the password input is required again.
(The screen requires password does not appear.)
If the personal computer or the finished inspection JIG II is changed, the password and the Com/User Characteristic Number are
changed. Therefore on the startup, the password input is required again.
3) Input the password and click [OK[Ent]], the following appears on the screen (Fig. 4-6-3).
Fig. 4-6-2
Fig. 4-6-3
4-6-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSAM)
1. Start
up ACSAM-S-VerX.XX.exe .
Fig.
4-6-4
2. When the Japanese window appears, click the [Setup] button, change the language to English.
Note:
Depending on the initial startup or setting made at the previous startup, the window differs.
3. Set the following contents in the SETUP window.
MODEL
Model to be adjustment in this time
Language English
State Final
Process
Service
Table
4-6-1
•
•
•
4. Confirm that all of the items are set.
Fig.
4-6-5
5. Click the [OK] to close the SETUP window.
4-6-4. About Inspection Procedure of Lens Adjustment Program (ActuatorCheckerSAM)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the in-
spection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one.
spection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one.
4-7. FINISHED ADJUSTMENT/INSPECTION (ActuatorCheckerSAM)
Equipment (Only the specific equipment is listed.)
Adhesive Bond (B-10)
4-7-1. Preparation
1. Connect the inspecting lens to the equipment. (Refer to 4-6-2. Connection of Finished Inspection JIG II and Startup of Lens Adjust-
ment Program (ActuatorCheckerSAM) .)
2. Start up the lens adjustment program (ActuatorCheckerSAM).
3. Click [Setup] and perform the initial setting. (Refer to 4-6-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSAM) .)
3. Click [Setup] and perform the initial setting. (Refer to 4-6-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSAM) .)
4-7-2. Finished Adjustment/Inspection Item
1. Adjustment/Inspection Method
1) Click
1) Click
[Start[Ent]].
2) Follow the instruction on the menu.
2. Adjustment/Inspection Item
1) AF/MF
1) AF/MF
Switch
2) LVDD1 Consumption Current
3) Adjust
3) Adjust
PI
4) Focus Pattern (Motor)
5) Stopping Accuracy
6) Write
5) Stopping Accuracy
6) Write
⊿
SB
7) Focus Pattern
8) Search
8) Search
Focus-Adj
Note:
This item is not adjusted automatically in case of starting
Adjustment/Inspection with clicking [Start[Ent]].
4-1-2. Adjustment Flow Chart
•
Fig. 4-7-1
Fig. 4-7-1
Click on the first or last page to see other SAL85F28 service manuals if exist.