Sony SAL85F14Z Service Manual ▷ View online

HELP
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
HELP17
Anti-diffusion agent (A-20): J-6082-611-A
Grease (G-85):
J-6082-626-A
Apply the anti-diffusion agent (A-20) and the grease (G-85) to the indicated location of 1st moving barrel.
HELP18
Anti-diffusion agent (A-20): J-6082-611-A
Apply the anti-diffusion agent (A-20) to the indicated portions of 2nd move frame lens block.
1st Ball Frame Lens Block
1st Moving Barrel
Apply the anti-diffusion agent (A-20) 
(All round)
Apply the anti-diffusion
agent (A-20) 
(All round)
Apply the grease (G-85) 
(All round)
2nd Move Frame Lens Block
Apply the anti-diffusion agent (A-20) 
(All round)
Apply the anti-diffusion 
agent (A-20) (All round)
HELP
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
HELP19
Adhesive bond (B-10): J-6082-612-A
1.
Tighten the cam tube retainer as far as it goes to the focus cam ring with the lens special fixture, and loosen by 2 to 5mm.
2.
Keeping the cam tube retainer stopped carefully, move the fixed barrel in the arrow direction.
Confirm that the fixed barrel moves a little at this moment. (Less than 0.01mm)
3.
Apply the adhesive bond (B-10) to two indicated locations in figure.
4.
After assembling, confirm that the focus cam ring rotates smoothly.
5.
Adjust by rotating the fixed barrel so that the position of hole for installing the distance tube stopper comes to the position of range A
shown in figure of focus cam ring.
Cam Tube
A
Cogwheel
Cam Tube Retainer
Focus Cam Ring
Fixed Barrel
Fixed Barrel
25 to 35 mm
Cam Tube
Cam Tube Retainer
Apply the adhesive bond (B-10) 
(Two places in the width of 25 to 35 mm.)
Apply the adhesive bond (B-10) 
(Two places in the width of 25 to 35 mm.)
HELP
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
HELP20
1.
Affix the main flexible setting (A) tape to the fixed barrel, aligning with the hole.
2.
Peel the back paper off the main flexible setting (A) tape and affix it to the main flexible unit, aligning with the hole as an index.
Note:
When affixing, eliminate bending or floating from the trace of flexible unit.
3.
Peel the back papers (2 sheets) off the main flexible setting (A) tape of main flexible unit
4.
Affix the main flexible unit to the inner side of fixed barrel.
5.
Affix 2 sheets of polyester tape (black) 10mm to the locations indicated in figure.
Fixed Barrel
Hole
Main Flexible Setting (A) Tape
Main Flexible Setting (B) Tape
Main Flexible Unit
Fixed Barrel
Polyester Tape (Black) 10 mm
HELP
SAL85F14Z (Planar 1.4/85) (Planar T
*
 85mm F1.4 ZA)
6.
Install the ground spring to the position indicated in figure with two screws.
HELP21
Grease (G-35):
J-6082-621-A
Anti-diffusion agent (A-20): J-6082-611-A
Apply the grease (G-35) to the specified portions (five locations on the groove) of focus cam ring and the anti-diffusion agent (A-20) to
the specified portions.
HELP22
Anti-diffusion agent (A-20): J-6082-611-A
Adhesive bond (B-40):
J-6082-614-A
Grease (G-35):
J-6082-621-A
1.
Apply the adhesive bond (B-40) to the screwed portion of focus stopper and tighten the fixed barrel with the focus stopper.
2.
Apply the anti-diffusion agent (A-20) and the grease (G-35) to the indicated portions of fixed barrel.
Ground Spring
Screw
Apply the grease (G-35) 
(To the groove in 5 places)
Apply the anti-diffusion 
agent (A-20) (All round)
Fixed Barrel
Apply the grease (G-35) (To the groove in 8 places)
Focus Stopper
Apply the adhesive bond (B-40)
Apply the grease (G-35) (All round)
Apply the grease (G-35) (All round)
Apply the grease (G-35) 
(All round)
Apply the anti-diffusion agent 
(A-20) (All round)
Apply the anti-diffusion agent (A-20) (All round)