4-12
SAL24F20Z (Distagon 2/24 ZA T * SSM) (Distagon T * 24mm F2 ZA SSM)
2.  Startup of Lens Adjustment Program (ActuatorCheckerSSM)
1)  Turn on the personal computer and the finished inspection JIG II.
2) Start up ACSSM-S-VerX.XX.exe  from an arbitrary folder.
Note:
At the first time using, the followings appear on the screen (Fig. 4-7-3).
It is required to ask HQ about the password for the Com/User Characteristic Number and the manufacturer/type name of the personal 
computer.
Ex.  Com/User Characteristic Number :  iYdDZfq9q
 
Personal Computer : 
SONY PCV-RZ33P
It is no need to input password to the computer once registered.
(The screen requires password does not appear.)
If the personal computer or the finished inspection JIG II is changed, the password and the Com/User Characteristic Number are 
changed.Therefore on the startup, the password input is required again
3) Input the password and click [OK [Ent]], the following appears on the screen (Fig. 4-7-4).
Fig. 4-7-3
Fig. 4-7-4
4-7-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM)
1) Start 
up ACSSM-S-VerX.XX.exe .
 
 Fig. 
4-7-5
2)  When the Japanese window appears, click the [Setup] button, change the language to English.
Note: 
Depending on the initial startup or setting made at the previous startup, the window differs.
3)  Set the following contents in the SETUP window.
MODEL 
Model to be adjustment in this time
Language English
State 
Final or Half
 Table 
4-7-1
4)  Confirm that all of the items are set, and click [Save].
 
 Fig. 
4-7-6
5)  Click the [Finish] to close the SETUP window.
4-7-4. About Inspection Procedure of Lens Adjustment Program (ActuatorCheckerSSM)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the in-
spection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one. 
4-8.  HALF COMPLETION ADJUSTMENT/INSPECTION (ActuatorCheckerSSM)
HALF COMPLETION INSPECTION (ActuatorChecker)
Half Completion JIG
Note:
  Please make the Half Completion JIG in each service station.
 
  For how to create a half completion JIG, refer to Note 6 of  4-1-1. List of Service Tools and Equipment.
4-8-1. Preparation
1.  Connect the inspecting lens to the equipment. (Refer to  4-7-2. Connection of Finished Inspection JIG II/Half Completion JIG and 
Startup of Lens Adjustment Program (ActuatorCheckerSSM) .)
2.  Start up the lens adjustment program (ACSSM-S-VerX.XX.exe).
3. Click 
[
Setup
]
 and perform the initial setting. (Refer to  4-7-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM) .)
Note:
   When the Multi Serial window opens, take the following actions.
 
Process No. 
You need not enter process number.
 
Serial No. 
When the mount block assy is replaced, enter a serial number.
 
CZ No. 
Enter a CZ number in the following cases.
 
 
When the mount block assy is replaced
 
 
When the name ring is replaced
 Fig. 
4-8-1
4-13
SAL24F20Z (Distagon 2/24 ZA T * SSM) (Distagon T * 24mm F2 ZA SSM)
4-8-2. Half Completion Adjustment/Inspection Item
Perform Half Completion Adjustment/Inspection items in the order as shown below.
1. Adjustment/Inspection Method
1) Click 
[Start[Ent]].
2)  Follow the instruction on the menu.
2. Adjustment/Inspection Item
1)  Adjust Focus Brush
2)  Focus Pattern (Motor)
3)  Adjust & Check MR
4) Focus Aging
5)  Adjust Driving Frequency & Gain
6) Focus Load
7) Check Sound
8) Search 
Focus-Adj
Note 1:
  This item is not adjusted automatically in case of starting Adjust-
ment/Inspection with clicking
 
[Start[Ent]].
Note 2:
 When performing Adjust & Check MR  from [Start[Ent]], the 
following dialog box appears in some cases. At this time, a mes-
sage  Retry?  appears even when the adjustment has been suc-
cessfully completed. Click  [No[BS]]  to go to the next step.
 
 Fig. 
4-8-3
4-1-2. Adjustment Flow Chart
4-8-3. Focus Brush Position Check/Adjustment
Equipment (Only the specific equipment is listed.)
Adhesive Bond (B-10)
1. Preparation
1)  Disassemble or assemble the checking lens and make it in the state shown in Fig. 4-8-4.
Brush (Focus)
 Fig. 
4-8-4
Fig. 4-8-2
Fig. 4-8-2
2. Check Method
1)  Set the focus to the infinity end.
2)  Click [Search Focus-Adj]. 
3)  If the focus brush locates on the Inf-Adj-Point, the following pop-up window appears.
 Fig. 
4-8-5
3.   Adjustment Method
1)  Loosen one screw fixing the focus brush and adjust the brush position.
Note:
  Adjust so that the cut portion A of pattern of focus encoder flexible board matches with the contact portion B of brush.
Brush (Focus)
A
B
Apply the grease (B-10)
 Fig. 
4-8-6
2)  After finishing the adjustment, apply the adhesive bond (B-10) to the head of screw. (Refer to Fig. 4-8-6.)
4-1-2. Adjustment Flow Chart
4-8-4.   Adjust & Check MR
Equipment (Only the specific equipment is listed.)
Adhesive Bond (B-10)
1.  Preparation
1)  Set the lens to the state of Fig. 4-7-2 in  4-7-2. Connection of Finished Inspection JIG
/Half Completion JIG and Startup of Lens Ad-
justment Program (ActuatorCheckerSSM).
2. Check/Adjustment Method
1)  Click [Adjust & Check MR].
2)   The processing proceeds to Adjust & Check MR. Enter the upper three digits of the value printed on the flexible board of the ultrasonic 
motor (stator).
 
Example:  When the value is  174
 
 
Ultrasonic motor frequency: 174
 Fig. 
4-8-7
4-14
SAL24F20Z (Distagon 2/24 ZA T * SSM) (Distagon T * 24mm F2 ZA SSM)
174076
 Fig. 
4-8-8
3)  When no problem is found in [Adjust & Check MR],  OK  appears. If  OK  does not appear, move the MR sensor position and adjust 
MR.
 Fig. 
4-8-9
MR sensor assy block
 Fig. 
4-8-10
4)  After adjusting, Apply the adhesive bond (B-10) to the indicated portion.
Apply the grease (B-10)
 
Fig. 4-8-11
4-1-2. Adjustment Flow Chart
4-9. FINISHED ADJUSTMENT/INSPECTION (ActuatorCheckerSSM)
HALF COMPLETION INSPECTION (ActuatorChecker)
Adhesive Bond (B-10)
4-9-1. Preparation
1.  Connect the inspecting lens to the equipment. (Refer to "4-7-2. Connection of Finished Inspection JIG II/Half Completion JIG and 
Startup of Lens Adjustment Program (ActuatorCheckerSAM)".)
2.  Start up the lens adjustment program (ACSSM-S-VerX.XX.exe).
3.  Click [Set.up] and perform the initial setting. (Refer to  4-7-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM) .)
Note:
   When the Multi Serial window opens, take the following actions.
 
Process No. 
You need not enter process number.
 
Serial No. 
When the mount block assy is replaced, enter a serial number.
 
CZ No. 
Enter a CZ number in the following cases.
 
 
When the mount block assy is replaced
 
 
When the name ring is replaced
 Fig. 
4-9-1
4-9-2. Completion  Adjustment/Inspection  Item
1. Adjustment/Inspection Method
1) Click 
[Start[Ent]].
2)  Follow the instruction on the menu.
2. Adjustment/Inspection Item
1) Write 
SB
2) AF/MF 
Switch
3)  Focus Hold Button
4)  LVDD1 Consumption Current
5)  Adjust & Check MR
6)  Adjust Driving Frequency & Gain
7) Focus Drive
7) Check Sound
8) Search 
Focus-Adj
Note 1:
  This item is not adjusted automatically in case of starting Ad-
justment/Inspection with clicking
 
[Start[Ent]].
Note 2:
 When performing Adjust & Check MR  from [Start[Ent]], the 
following dialog box appears in some cases. At this time, a 
message  Retry?  appears even when the adjustment has been 
successfully completed. Click  [No[BS]]  to go to the next 
step.
 
 Fig. 
4-9-3
4-1-2. Adjustment Flow Chart
Fig. 4-9-2
Fig. 4-9-2
4-15
SAL24F20Z (Distagon 2/24 ZA T * SSM) (Distagon T * 24mm F2 ZA SSM)
4-9-3. Focusing Error Amount Adjustment (Write SB)
1) Click 
[Write 
SB].
 [Select 
SB] window is displayed.
 
At this time, the current 
SB is highlighted.
2) Write the 
SB based on the error amount that was confirmed by the  4-5. Focusing Error Amount Check .
 Example)
 
When changing the focus to the front (Front focus):   Select the left side of the button (current 
SB) that is highlighted and press the 
[Enter] key.
 
When changing the focus to the rear (Rear focus): 
 Select the right side of the button (current 
SB) that is highlighted and press the 
[Enter] key.
 
 (0) 
 
(6)
 
To the front focus  To the rear focus
 Fig. 
4-9-4
3) Performs 
the 4-5. Focusing Error Amount Check , and check that the error amount is smaller than the reference value. 
 
If the error amount is larger than the reference value, perform [Write 
SB] again, and repeat steps 1) to 3) until the error amount be-
comes less than reference value.
4-1-2. Adjustment Flow Chart