DOWNLOAD Sony DSC-RX1RM2 (serv.man2) Service Manual ↓ Size: 13.4 MB | Pages: 126 in PDF or view online for FREE

Model
DSC-RX1RM2 (serv.man2)
Pages
126
Size
13.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL2
File
dsc-rx1rm2-sm2.pdf
Date

Sony DSC-RX1RM2 (serv.man2) Service Manual ▷ View online

2-9. 
Note on Attaching the EVF Block Section
When attaching the EVF Block Section, work with care between the EVF Block Section and gap (and step) of the front
cabinet.
About the attaching method, refer to the “Notes on Assembling the BTH Block Section”.
After attaching, perform that the clearance and step between front cabinet and EVF block section are within the following
specification.
Specification:
0.35 mm or less
0.30 mm or less
0.30 mm or less
convex 0.15 mm or less
Gap
Step
concave 0.1 mm or less
DSC-RX1RM2
2-17
2-10.  Notes on Attaching the IM Imager Unit and the CLC
When attaching the IM imager unit and the CLC, be careful about the pasting positions of the sheet and the tapes in the
figure below.
Tape AS (2040)
Tape AS (2040)
Sheet PD
ACF Reinforcement 
Tape (61100)
About attachment method, refer to the “Notes on Assembling the Overall Section-3”.
After attached the sheet and tapes, perform the operation check.
Operation check (After assembled the IM imager unit)
Pop up the VF Assy, confirm that the flexible board is not protruding to the red circle portion in the figure below.
Operation check (After assembling the unit)
About operation check after assembled the unit, refer to the 
“2-12. Note on After Attaching the LSV-1601A Device, the
IM Imager Unit and the CLC”
.
DSC-RX1RM2
2-18
2-11.  Notes on Attaching the LSV-1601A Device
When attaching the IM imager unit and the CLC, be careful about the pasting positions of the sheet and the tapes in the
figure below.
Tape P (4.5 x 25)
Tape AS (2040)
Sheet PD
ACF Reinforcement 
Tape (61100)
About attachment method, refer to the “Notes on Assembling the Overall Section-3”.
After attached the sheet and tapes, perform the operation check.
Operation check (After assembling the unit)
About operation check after assembled the unit, refer to the 
“2-12. Note on After Attaching the LSV-1601A Device, the
IM Imager Unit and the CLC”
.
DSC-RX1RM2
2-19
2-12.  Note on After Attaching the LSV-1601A Device, the IM Imager Unit
and the CLC
After attaching the LSV-1601A device, the IM imager unit and the CLC, perform the confirming of leak light according
to the following procedure.
1.
Cover the lens cap with the unit state.
2.
Insert the memory card to the camera.
Note
Use the memory card of a slow transfer speed.
• SD memory card : CLASS 4
• Memory stick : Mark 2
3.
Select MENU button → Setup → Setting reset → Shooting setting reset, reset the camera setting.
4.
Set the camera shooting setting as follows.
• Shooting mode : M
• Focus mode : MF (Infinity)
• Picture quality : RAW+JPEG
• ISO sensitivity : 3200
• Iris : F5.6
• WB : cloudiness
• DRO : OFF
• NR when Long seconds : OFF (MENU button → Shooting setting → NR when Long seconds)
OFF
±0±0±0
D-R
OFF
3:2
42
M
RAW+JAVCHD60i
OFF
Tv
M
25
MF
BULB
F5.6
ISO3200
DSC-RX1RM2
2-20
Page of 126
Display