2-3.
Note on Removing and Installing the Imager Board
With the following features, this unit is likely to capture foreign particles.
• The imager sensor size is large.
• The space between the imager sensor and the lens is small.
• The space between the imager sensor and the lens is small.
Therefore, pay close attention to foreign particles.
DSC-RX1RM2
2-5
2-4.
Note on Replacing the LSV-1601A Device and the IM Imager Unit
When replacing the LSV-1601A device and the IM imager unit, perform
“2-2-5. Imager DRA Data”
.
DSC-RX1RM2
2-6
2-5.
Note on Replacing the IM Imager Unit and the CLC
When replacing the IM imager unit and the CLC, perform
“2-2-6. CLC Data”
.
When replacing it, read the QR code of QR seal attached to the CLC.
Get the serial number of the CLC in accordance with following procedure.
1.
Get the serial number of the CLC in accordance with following procedure.
1.
There are two QR seals. Shoot the top of the QR code.
2.
Start "QR_Code_Reader_Ver[].[]"
3.
Click [Select Image], Select the image of QR code.
4.
Adjust the size of QR code to fit into the monitor and click [Start].
Tip
If the image is small (or large), the size is adjustable by [Ctrl]+[Scroll Up/Down] keys.
DSC-RX1RM2
2-7
5.
H and seven digits number is displayed.
HXXXXXXX
6.
Inquire to each HQ about the read serial number and get the CLC data.
DSC-RX1RM2
2-8