DOWNLOAD Sony DSC-RX1RM2 (serv.man2) Service Manual ↓ Size: 13.4 MB | Pages: 126 in PDF or view online for FREE

Model
DSC-RX1RM2 (serv.man2)
Pages
126
Size
13.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL2
File
dsc-rx1rm2-sm2.pdf
Date

Sony DSC-RX1RM2 (serv.man2) Service Manual ▷ View online

Section 2
Service Note
2-1. 
Operation Notes
2-1-1. 
Flexible Board
• Make sure that the conductive side of a flexible board does not have any stain or foreign materials.
• Do not touch the conductive side of flexible boards with bare hands.
• Plug in a flexible board straight, fully into the connector until it reaches the end inside.
Flexible
Board
Flexible
Board
Connector
Connector
Reference line
Flexible
Board
Connector
Connector
Flexible
Board
Reference line
Connector
Connector
Flexible
Board
Flexible
Board
Reference line
OK 
(The flexible board was plugged in 
straight and completely)
(The flexible board was plugged in 
crooked.)
NG 
NG 
(The flexible board was not plugged in 
completely.)
• When opening the connector's holder in direction A, do not open it with excessive force.
Holder
Connector
Flexible Board
A
A
• When closing the connector's holder, press it evenly while pushing a flexible board in direction B.
Holder
Insulation side
Connector
Flexible Board
B
• Make sure that the flat cable and flexible board are not cracked or bent at the contact end.
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
• Do not apply excessive force to the gilded flexible board.
2-1-2. 
Fine-Wire Coaxial Cable
• The proper way to disconnect a connector is to grab the connector instead of the wires. If you pull on the wires,
they might be broken.
• The proper way to connect a connector is to grab the connector instead of the wires. If you push on the wires, they
might be broken.
DSC-RX1RM2
2-1
2-2. 
Precaution on Replacing the SY-1059 Board
The board for repair is not recorded the information unique to a model. Therefore the following data are needed to write.
Note
The [LOAD AND WRITE] function in “ADJUSTMENT DATA BACKUP” on the DATA tab in the Adjust Manual
overwrites all data of the unit. Therefore execute the [LOAD AND WRITE] before performing the following operation.
2-2-1. 
Destination Data
The destination data stored in the repairing board is different from the destination setting stored in the board before
replacement in some cases.
When the board has been replaced with a repairing board, be sure to set the destination.
Method of the destination data write:
Start the Adjust Manual in the Adjust Station and execute the “Destination data write” on the ADJUST tab.
2-2-2. 
Restore Data
Before replacing the board with a repairing board, be sure to extract the data from the former one.
Method of the data extracting:
Start the Adjust Manual in the Adjust Station and execute the “RESTORE DATA” on the DATA tab.
2-2-3. 
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have
been written.
These IDs have not been written in a new repairing board. Therefore, after the board has been replaced, be sure to write
these IDs to a new repairing board.
Method of the ID writing:
Start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB SERIAL No. INPUT” on
the ADJUST tab.
2-2-4. 
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the
IC’s unique number (MAC address) must be reloaded.
Procedure of the MAC address update:
Note
Perform the below operations after all work has been done.
1.
Start the Adjust Manual in the Adjust Station and execute the “Wireless LAN Setting (MAC Address)” on
the ADJUST tab.
2.
Operate the unit to initialize of SSID/PW.
DSC-RX1RM2
2-2
Applicable parts:
• SY-1059 Board
Note
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required.
Accordingly, download the Flyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) and print out it, and attach
it to the set when returning the set to customer.
2-2-5. 
Imager DRA Data
When you replace to the SY repairing board, get the imager DRA data from the former SY board beforehand. After
replacing the SY board, perform "Imager DRA Data Write" on the Adjust manual to write the imager DRA data gotten.
Note
In the following cases, perform the “Imager DRA EBC Adj” and “Imager SF2 adj” on the Adjust Manual, and write the
imager DRA data.
• When you cannot get the imager DRA data from the unit before replacing the SY board
• When replacing the lens or the imager unit
SF2 adjustment chart (J-6082-803-A) is required in "Imager DRA SF2 adj".
Lens replacement
EBC adjustment
Perform "Imager DRA EBC adj" on the Adjust Manual
Imager unit replacement
SF2 adjustment
Perform "Imager DRA SF2 adj" on the Adjust Manual
Write the imager DRA data
Perform "Imager DRA Data Write" on the Adjust Manual
SY board replacement
Get imager DRA data
OK
NG
2-2-6. 
CLC Data
When you replace to the SY repairing board, get the CLC data from the former SY board beforehand. After replacing
the SY board, perform "CLC Data Carry" on the Adjust manual to write the CLC data gotten.
Note
• If you can not get the CLC data from the former SY board, inquire to each HQ. Get the CLC data with serial number
of the unit.
• When replacing the imager unit or the CLC, inquire to each HQ. Read the CLC serial number from QR code given
on the CLC. Get the CLC data from CLC serial number.
DSC-RX1RM2
2-3
CLC unit replacement
Read the QR code
Get the serial number of CLC
Imager unit replacement
Inquire to the each HQ
Get the CLC data from CLC serial number
Write the CLC data
Perform "CLC Data Carry" on the Adjust Manual
Inquire to the each HQ
Get the CLC data 
from unit serial number
SY board replacement
Get CLC data
OK
NG
DSC-RX1RM2
2-4
Page of 126
Display

Click on the first or last page to see other DSC-RX1RM2 (serv.man2) service manuals if exist.