5-26
2. VCO Adjustment (SY-59 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 7 of CN704 (HSY)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
D7 (NTSC)
DD (PAL)
Specified Value
f = 15734 ± 30 Hz (NTSC)
f = 15745 ± 30 Hz (PAL)
Menu setting:
VIDEO OUT of SET UP menu ............................................ NTSC
(This adjustment must be performed in NTSC mode, so don’t set
the menu setting to “PAL”.)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F0, set data: 01.
3)
Select page: D, address: D7, change the data and set the HSY
frequency (f) to the NTSC specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: D, address: DD, change the data and set the HSY
frequency (f) to the PAL specified value.
6)
Press the PAUSE button.
7)
Select page: 5, address: F0, set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
3. D Range Adjustment (SY-59 board)
Set the D range of the LCD driver to the specified value. If deviated,
the LCD screen will become blackish or saturated (whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN704 (VG)
External trigger: Pin 8 of CN704
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D5
Specified Value
A = 3.62 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 03.
3)
Select page: D, address: D5, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 5, address: F1, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-16.
A
2H
Pedestal
Pedestal
5-27
4. Bright Adjustment (SY-59 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN704 (VG)
External trigger: Pin 8 of CN704
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D0
Specified Value
A = 2.00 ± 0.08V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 03.
3)
Select page: 2, address: 10, set data: 01.
4)
Select page: D, address: D0, change the data and set the voltage
(A) between the pedestal and GAMMA1 limiter level to the
specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 2, address: 10, set data: 00.
7)
Select page: 5, address: F1, set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-17.
5. Contrast Adjustment (SY-59 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN704  (VG)
External trigger: Pin 8 of CN704
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D4
Specified Value
A = 3.31 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 03.
3)
Select page: D, address: D4, change the data and set the voltage
(A) between the pedestal and 10 steps peak to the specified
value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 5, address: F1, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-18.
A
2H
GAMMA 1 limiter level
Pedestal
A
2H
10 steps peak
Pedestal
5-28
6. Color Adjustment (SY-59 board)
Set the color saturation to the standard value. If deviated, the color
will be too dark or light.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN704 (VG)
External trigger: Pin 8 of CN704
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D1
Specified Value
A = 544 ± 50mV
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 04.
3)
Select page: D, address: D1, change the data and set the voltage
(A) between the white 100% (Reference level) and green to
the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 5, address: F1, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-19.
7. V-COM Level Adjustment (SY-59 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 8 of CN704 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D6
Specified Value
A = 6.30 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: D6, change the data and set the V-
COM signal level (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-20.
A
2H
White 100 %
Green
A
2H
5-29
8. V-COM Adjustment (SY-59 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
D8
Specified Value
The brightness difference between the
section A and section B is minimum.
Note:
Perform “Bright Adjustment” and “Contrast Adjustment” before this
adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 02.
3)
Select page: 2, address: 10, set data: 02.
4)
Select page: D, address: D8, change the data so that the
brightness of the section A and that of the section B is equal.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 5, address: F1, set data: 00.
7)
Select page: 2, address: 10, set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
Fig. 5-1-21.
9. White Balance Adjustment (SY-59 board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
D2, D3
Specified Value
The LCD screen should not be
colored.
Note 1:
Use the AC power adaptor during this adjustment.
Note 2:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC803
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 02.
3)
Select page: D, address: D2 and D3, set the data to the initial
value.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
4)
Check that the LCD screen is not colored. If colored, change
the data of page: D, address: D2 and D3 so that the LCD screen
is not colored.
Note:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
5)
Select page: 5, address: F1, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
A
A
A
A
B
B
B
B
Data
D2
B9
D3
B7
Address
Page of 89