5-37
5. Contrast Adjustment (Control Switch Block (FK) )
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN002 (VG)
External trigger: Pin 8 of CN002
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
84
Specified Value
A = 3.31 ± 0.07V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 03.
3)
Select page: D, address: 84, change the data and set the voltage
(A) between the 10 steps peak and pedestal to the specified
value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 5, address: F1, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Fig.5-1-21.
A
2H 
GAMMA1 limiter level
Pedestal
Fig.5-1-22.
A
2H 
10 steps peak
Pedestal
4. Bright Adjustment (Control Switch Block (FK) )
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN002 (VG)
External trigger: Pin 8 of CN002
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
80
Specified Value
A = 2.17 ± 0.08V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 03.
3)
Select page: 2, address: 10, and set data: 01.
4)
Select page: D, address: 80, change the data and set the voltage
(A) between the pedestal and GAMMA1 limiter level to the
specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 2, address: 10, and set data: 00.
7)
Select page: 5, address: F1, set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
5-38
7. V-COM Level Adjustment (Control Switch Block (FK) )
Set the common electrode drive signal level of LCD to the specified
value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 8 of CN002 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
86
Specified Value
A= 6.50 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 03.
3)
Select page: D, address: 86, change the data and set the COM
signal level (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 5, address: F1, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Fig.5-1-23.
A
2H
Green 
White (100%)
A
2H
Fig.5-1-24.
6. Color Adjustment (Control Switch Block (FK) )
Set the color saturation to the standard value. If deviated, the color
will be to dark or light.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN002 (VG)
External trigger: Pin 8 of CN002
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
81
Specified Value
A= 544 ± 50mV
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 04.
3)
Select page: D, address: 81, change the data and set the voltage
(A) between the white 100% (Reference level) and green to
the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 5, address: F1, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
5-39
9. White Balance Adjustment (HI-70 board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
82, 83
Specified Value
The LCD screen should not be colored.
Note 1:
Use the AC power adaptor during this adjustment.
Note 2:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC802 (LCD DRIVE)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 02.
3)
If used AC adapter, select page: D, address: 1C, after noting
the data, set data: 00, and press PAUSE button.
If used battery, select page: D, address: 1D, after noting the
data, set data: 0C.
4)
Select page: D, address: 82 and 83, set the data to the initial
value.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
5)
Check that the LCD screen is not colored. If colored, change
the data of page: D, address: 82 and 83 so that the LCD screen
is not colored.
Note:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
6)
Select page: D, address: 1C or 1D, set the data noted down at
step 3).
7)
Select page: 5, address: F1, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
Address
Data
82
B9
83
B7
Fig.5-1-25.
A
A
A
A
B
B
B
B
8. V-COM Adjustment
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
88
Specified Value
The brightness difference between the
section A and section B is minimum.
Note 1 :
Perform “Bright Adjustment” and “Contrast Adjustment” before
this adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: 01.
3)
Select page: 2, address: 10, and set data: 02.
4)
Select page: D, address: 88, change the data so that the
brightness of the section A and that of the section B is equal.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 5, address: F1, and set data: 00.
7)
Select page: 2, address: 10, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
5-40
1-6.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Battery End Adjustment (SY-56 board)
Check the battery end voltage.
Mode
STILL
Subject
Arbitrary
Measurement Point
Display data of page: 2, address: 51
Measuring Instrument
Adjustment remote commander
Adjustment Page
D
Adjustment Address
30 to 34, 4A
Connection:
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-1-24.
Adjusting method:
1)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 3.5 ± 0.1Vdc.
2)
Turn off the power supply.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Turn on the power supply.
5)
Insert the memory stick to the unit, and set to the STILL mode.
6)
Set the FOCUS switch MANUAL side.
7)
Select page: 0, address: 01, and set data: 01.
8)
Decrease the output voltage of the regulated power supply so
that the digital voltmeter display is 3.00 ± 0.01Vdc.
9)
Select page: 2, address: 51, read the data, and this data is named
Vref.
10) Select page: D, address: 30, set data: Vref, and press the PAUSE
button of the adjustment remote commander.
11) Convert Dref to decimal notation, and obtain Dref’. (Refer to
Table 5-2-1. “Hexadecimal-decimal conversion table” of “5-2.
Service mode”)
12) Calculate V
31
', V
32
', V
33
', V
34
' and V
4A
' using following equations
(decimal calculation), convert it to a hexadecimal number, and
input each adjustment address.
Address: 31
V
31
' = Vref’+3
Address: 32
V
32
' = Vref’+10
Address: 33
V
33
' = Vref’+10
Address: 34
V
34
' = Vref’+10
Address: 4A
V
4A
' = Vref’+17
Note:
After setting each data, be sure to press the PAUSE button.
13) Select page: 0, address: 01, and set data: 00.
Fig.5-1-26.
Regulated power supply 
(3.5 
±
 0.1 Vdc)
Digital voltmeter
CN001
1
3
DD-131 BOARD
Page of 127
Display