5-29
13. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
13-1. Color Reproduction Adjustment (Without ND Filter)
Mode
STILL
Subject
Color bar chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
41 to 48, 5C to 5F
Note 1:
This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input” and “Auto White Balance
Adjustment”.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If not, turn the
power of the unit OFF/ON.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Check that the picture frame is set to the specified position.
(Refer to “5. Picture Frame Setting”.)
4)
Select page: B, address: 41, set data: 30, and press the PAUSE
button.
5)
Select page: F, address: 37, and set data: 9B.
6)
Select page: 6, address: 01, set data: AB, and press the PAUSE
button.
7)
Select page: 6, address: 01, set data: A9, and press the PAUSE
button.
(The color reproduction adjustment (without ND filter) is
performed and the adjustment data is stored in page: F, address:
41 to 48 and 5C to 5F.)
8)
Select page: 6, address: 02, and check that the data is “01”.
9)
Perform “Color Reproduction Check” and “Processing after
Completing Adjustments”.
Processing after Completing Adjustments:
1)
Select page: B, address: 41, set data: 00, and press the PAUSE
button.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 37, set data: 93, and press the PAUSE
button.
4)
Select page: 5, address: F1, and set data: 00.
5)
Select page: 0, address: 01, and set data: 00.
13-2. Color Reproduction Adjustment (With ND Filter)
Mode
STILL
Subject
Color bar chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
51 to 58, 60 to 63
Note 1:
This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input” and “Auto White Balance
ND Filter Compensation Adjustment”.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If not, turn the
power of the unit OFF/ON.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Check that the picture frame is set to the specified position.
(Refer to “5. Picture Frame Setting”.)
4)
Select page: B, address: 41, set data: 30, and press the PAUSE
button.
5)
Select page: F, address: 37, set data: 9B, and press the PAUSE
button.
6)
Select page: 6, address: 1C, set data: 03, press PAUSE button,
and wait for one second.
7)
Select page: 6, address: 12, set data: 80, press PAUSE button,
and wait for two seconds.
8)
Select page: 6, address: 12, set data: 00, press PAUSE button,
and wait for two seconds.
9)
Select page: 6, address: 01, set data: C3, and press the PAUSE
button.
10) Select page: 6, address: 01, set data: C1, and press the PAUSE
button.
(The color reproduction adjustment (with ND filter) is
performed and the adjustment data is stored in page: F, address:
51 to 58 and 60 to 63.)
11) Select page: 6, address: 02, and check that the data is “01”.
12) Perform “Color Reproduction Check” and “Processing after
Completing Adjustments”.
Processing after Completing Adjustments:
1)
Select page: B, address: 41, set data: 00, and press the PAUSE
button.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 1C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: F, address: 37, set data: 93, and press the PAUSE
button.
5)
Select page: 5, address: F1, and set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
5-30
13-3. Color Reproduction Check
Mode
STILL
Subject
Color bar chart
(Color reproduction adjustment frame)
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Specified Value
Each center of all color luminance
points should settle within each color
reproduction frame.
Note:
This check should be performed at NTSC mode only.
(Click MENU button [SETUP]     [VIDEO OUT]     [NTSC].)
Checking method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: E, address: 52, after noting down the data, set
data: 0B, and press the PAUSE button of the adjustment remote
commander.
3)
Select page: 5, address: F1, and set data: FF.
4)
Select page: B, address: 41, set data: 30, and press the PAUSE
button.
5)
Select page: F, address: 37, set data: 9B, and press the PAUSE
button.
6)
Select page: 6, address: 10, and set data: 01.
7)
Select page: 6, address: 01, set data: 0F, and press the PAUSE
button.
8)
Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
9)
Check that each center of all color luminance points is settled
in each color reproduction frame.
10) Select page: 6, address: 1C, set data: 03, press the PAUSE button
and wait for one second.
11) Select page: 6, address: 12, set data: 80, press the PAUSE button
and wait for two seconds.
12) Select page: 6, address: 12, set data: 00, press the PAUSE button
and wait for two seconds.
13) Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
14) Check that each center of all color luminance points is settled
in each color reproduction frame.
Fig.5-1-17.
Processing after Completing Adjustments:
1)
Select page: E, address: 52, set the data noted down at step 2),
and press the PAUSE button of the adjustment remote
commander.
2)
Select page: B, address: 41, set data: 00, and press the PAUSE
button.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
4)
Select page: 6, address: 1C, set data: 00, and press the PAUSE
button.
5)
Select page: F, address: 37, set data: 93, and press the PAUSE
button.
6)
Select page: 6, address: 10, and set data: 00.
7)
Select page: 5, address: F1, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
R-Y
R
G
M
G
Y
L
C
Y
B
Burst position
NTSC mode
5-31
14. White Balance Check
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video output terminal
Measuring Instrumen
Vectorscope
Specified Value
Fig. 5-1-16. A to C
Checking method:
1)
Check that the lens is not covered with either filter.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 5, address: F1, and set data: FF.
4)
Select page: B, address: 41, set data: 30, and press the PAUSE button.
5)
Select page: F, address: 37, set data: 9B, and press the PAUSE button.
6)
Select page: 6, address: 01, set data: 0F, and press the PAUSE
button of the adjustment remote commander.
7)
Check that the center of the white luminance point is within
the circle shown Fig. 5-1-16. (A).
8)
Select page: 6, address: 1C, set data: 03, and press the PAUSE
button and wait for one second.
9)
Check that the center of the white luminance point is with in
the circle shown Fig. 5-1-18. (A).
10) Select page: 6, address: 1C, set data: 00, and press the PAUSE
button.
11) Select page: 6, address: 01, set data: 23, and press the PAUSE
button.
12) Place the C14 filter on the lens.
13) Check that the center of the white luminance point settles in
the circle shown Fig. 5-1-18. (B).
14) Remove the C14 filter, and place the ND filter 1.5 (1.0 +0.4+0.1)
on the lens.
15) Check that the white luminance point stopped moving, and then
remove the ND filter 1.5.
16) Check that the center of the white luminance point settles within
the circle shown Fig. 5-1-18. (C).
Processing after Completing Adjustments:
1)
Select page: B, address: 41, and set data: 00.
2)
Select page: F, address: 37, and set data: 93.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE button.
4)
Select page: 5, address: F1, and set data: 00.
5)
Select page: 0, address: 01, and set data: 00.
R-Y
3mm
0.5mm
B-Y
3mm
R-Y
B-Y
2.0mm
6mm
6mm
R-Y
B-Y
6mm
1.0mm
6mm
Fig.5-1-18.(A)
Fig.5-1-18.(B)
Fig.5-1-18.(C)
15. Strobe White Balance Adjustment
Adjust the white balance when the strobe light flashes.
Mode
STILL
Subject
Flash adjustment box (Note5)
(1.0m from the front of the lens)
Adjustment Page
F
Adjustment Address
4D, 4E, 68, 69, 6A, 6B
Note 1:
Perform this adjustment in the flash adjustment box.
Note 2:
Any light other than the strobe light should not light up the plate.
Note 3:
This adjustment should be carried out upon completion of
“HALL Adjustment”, “Flange Back Adjustment”, “Light Level
Adjustment” and “Auto White Balance Adjustment”.
Note 4:
Check that the data of page: 6, address: 02 is “00”. If not, turn the
power of the unit OFF/ON.
Note 5:
Refer to “4. Preparing the Flash Adjustment Box”. (See page 5-7)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: B, address: 41, set data: 30, and press the PAUSE
button.
4)
Select page: 6, address: 90, and set data: 00.
5)
Select page: 6, address: 91, and set data: 00.
6)
Select page: 6, address: 92, and set data: 00.
7)
Select page: 6, address: 93, and set data: 60.
8)
Select page: 6, address: 2C, and set data: 01.
9)
Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
10) Select page: 6, address: 01, set data: B9, and press the PAUSE
button.
11) Check the flashing of the strobe light.
(The strobe white balance adjustment is performed and the
adjustment data is stored in page: F, address: 4D, 4E, 68, 69,
6A and 6B.)
12) Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 2C, and set data: 00.
2)
Select page: 6, address: 93, and set data: 00.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
4)
Select page: B, address: 41, set data: 00, and press the PAUSE
button.
5)
Select page: 5, address: F1, and set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
5-32
16. Strobe Light Level and White Balance Check
Check the light level regulation and the white balance when the
strobe light flashes.
Mode
STILL
Subject
Flash adjustment box (Note4)
(1.0m from the front of the lens)
Measurement Point
Display data of page: 1
Measuring Instrument
Adjustment remote commander
Specified value
Y level data: 68 to A0 (Note6)
R-Y data: FA to FF or 00 to 06 (Note7)
B-Y data: FA to FF or 00 to 06 (Note7)
Note 1:
Perform this adjustment in the flash adjustment box.
Note 2:
Any light other than the strobe light should not light up the plate.
Note 3:
This adjustment should be carried out upon completion of
“HALL Adjustment”, “Flange Back Adjustment”, “Light Level
Adjustment”, “Auto White Balance Adjustment” and “Strobe White
Balance Adjustment”.
Note 4:
Refer to “4. Preparing the Flash Adjustment Box”. (See page 5-7)
Note 5:
Check that the data of page: 6, address: 02 is “0”.  If not, turn the
power of the unit OFF/ON.
Note 6:
Display data of page 1 of the adjustment remote commander.
1 : 00 : XX
Y level data
Note 7:
Display data of page 1 of the adjustment remote commander.
1 : XX : XX
B-Y data
R-Y data
Checking method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: 6, address: 90, and set data: 00.
4)
Select page: 6, address: 91, and set data: 00.
5)
Select page: 6, address: 92, and set data: 00.
6)
Select page: 6, address: 93, and set data: 60.
7)
Select page: 6, address: 2C, and set data: 01.
8)
Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
9)
Select page: 6, address: 01, set data: 67, and press the PAUSE
button.
10) Check the flashing of the strobe light.
11) Select page: 0, address: 03, and set data: 01.
12) Select page: 1, and check that the Y level data satisfies the
specified value. (Note6)
13) Select page: 0, address: 03, and set data: 02.
14) Select page: 1, and check that the R-Y data and B-Y data satisfy
the specified value respectively.(Note7)
Processing after Completing Adjustments:
1)
Select page: 0, address: 03, and set data: 00.
2)
Select page: 6, address: 2C, and set data: 00.
3)
Select page: 6, address: 93, and set data: 00.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: E, address: 8F, set data: 01, and press the PAUSE
button.
6)
Select page: E, address: 6F, set data: 24, and press the PAUSE
button.
7)
Select page: E, address: 71, set data: 10, and press the PAUSE
button.
8)
Select page: F, address: B9, set data: 00, and press the PAUSE
button.
9)
Select page: 5, address: F1, and set data: 00.
10) Select page: 0, address: 01, and set data: 00.
17. CCD Black Defect Compensation
Mode
STILL
Subject
Clear chart
(25 cm from the front of the lens)
(Note1)
Measurement Point
Display data of page: 6, address: 55
Measuring Instrument
Adjustment remote commander
Adjustment Page
7
Adjustment Address
60 to 87
Specified value
Data < 0A: OK, Data > 0B: NG
Note 1:
Check that there are no dust, no dirt and no reflection on the clear
chart.
Note 2:
Any subject other than the clear chart should not be in the screen.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: F, address: DF, after noting down the data, set
data: 4C, and press the PAUSE button.
4)
Select page: 6, address: 2C, and set data: 01.
5)
Select page: 6, address: 90, and set data: 00.
6)
Select page: 6, address: 91, and set data: 03.
7)
Select page: 6, address: 92, and set data: 00.
8)
Select page: 6, address: 93, and set data: 00.
9)
Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
10) Select page: 6, address: 30, set data: 07, and wait for four
seconds.
11) Select page: 6, address: 01, set data: 8D, and press the PAUSE
button.
(The CCD Block defect compensation is performed and the
adjustment data is stored in page: 7, address: 60 to 87.)
12) Select page: 6, address: 02, and check that the data changes to
“01”.
13) Select page: 6, address: 55 and check that the data satisfies
specified value.
(This value means the number of the Black CCD defect.)
Processing after Completing Adjustments:
1)
Select page: F, address: DF, set the data noted down at step 3),
and press the PAUSE button.
2)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
3)
Select page: 6, address: 2C, and set data: 00.
4)
Select page: 6, address: 91, and set data: 00.
5)
Select page: 6, address: 30, and set data: 00.
6)
Select page: 5, address: F1, and set data: 00.
7)
Select page: 0, address: 01, and set data: 00.
Page of 127