DOWNLOAD Sony STR-DA2800ES Service Manual ↓ Size: 17.66 MB | Pages: 127 in PDF or view online for FREE

Model
STR-DA2800ES
Pages
127
Size
17.66 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
str-da2800es.pdf
Date

Sony STR-DA2800ES Service Manual ▷ View online

STR-DA2800ES
5
Ver. 1.3
NOTE  OF  REPLACING  THE  IC3903  AND  IC3904  ON  
THE  DCDC  BOARD
IC3903 and IC3904 on the DCDC board cannot exchange with 
single. When these parts are damaged, exchange the complete 
mounted board.
NOTE  OF  REPLACING  THE  IC3500  AND  IC3700  ON  
THE  D-VIDEO  BOARD
IC3500 and IC3700 on the D-VIDEO board cannot exchange with 
single. When these parts are damaged, exchange the complete 
mounted board.
NOTE  OF  REPLACING  THE  IC3505  AND  IC3506  ON  
THE  D-VIDEO  BOARD
Replacement of IC3505 and IC3506 on the D-VIDEO board used 
in this unit requires a special tool.
NOTE  OF  REPLACING  THE  IC5001  ON  THE  DSP 
BOARD
IC5001 on the DSP board cannot exchange with single. When this 
part is damaged, exchange the complete mounted board.
NOTE  OF  REPLACING  THE  IC101, IC501  AND  IC2601  
ON  THE  NETWORK  BOARD
IC101, IC501 and IC2601 on the NETWORK board cannot ex-
change with single. When these parts are damaged, exchange the 
complete mounted board.
NOTE  OF  REPLACING  THE  IC106,  IC107,  IC206  AND  
IC207  ON  THE  NETWORK BOARD
Replacement of IC106, IC107, IC206 and IC207 on the NET-
WORK board used in this unit requires a special tool.
MODEL  IDENTIFICATION
Distinguish the model by UWA-C4Z connector on back panel.
– Back Panel –
US and Canadian models:
UWA-C4Z connector 
does exist.
AEP model:
UWA-C4Z connector 
does not exist.
NEW/FORMER  TYPES  DISCRIMINATION (US model only)
In US model of this unit, the specifi cations have been changed in 
the midway of production.
Repair after distinguishing each type unit to doing the repair refer-
ring to the following.
– Back Panel –
– Remote Control –
SERIAL NO.
88xxxxx : Former type
85xxxxx : New type
Not available  : Former type
Available 
: New type
Remote control name
RM-AAU155  : Former type
RM-AAU195  : New type
“NETFLIX” button
Available 
: Former type
Not available  : New type
“SUBTITLE” symbol
Available 
: Former type
Not available  : New type
STR-DA2800ES
6
CAPACITOR  ELECTRICAL  DISCHARGE  PROCESSING
When checking the board, for the electric shock prevention, con-
nect the resistors to both ends of respective capacitors (C905 on 
the ACDC board) to discharge the capacitors (C905 on the ACDC 
board).
– ACDC Board (Conductor Side) –
C905
800 
:/2 W
ADVANCE  PREPARATION  OF  REPAIR
(US and Canadian models only)
This unit can perform “PRO-UPGRADE” by C4 (Control4) dealer.
When the user is performing “PRO-UPGRADE”, GUI of C4 
(Control4) world is displayed.
Display GUI in the following procedure and confi rm the state of 
displayed GUI.
Connection:
STR-
DA2800ES
monitor
D-VIDEO board
HDMI OUT A ARC connector
(CN3502)
HDMI cable
Procedure:
1.  Press the [
?/1
] button to turn on the main power.
2.  Press the [HOME] button of remote commander.
3.  “PRO-UPGRADE” is not performed when the following 
screen is displayed.
Note: If the following processing is performed to this unit by which 
“PRO-UPGRADE” was performed, this unit returns to the state 
before “PRO-UPGRADE” is performed.
 
• 
Complete NETWORK board replacing
 • 
Factory 
reset
 
Since the change to C4 (Control4) world can perform only by 
C4 (Control4) dealer, fully work carefully.
NOTE  OF  REPLACING  THE  COMPLETE NETWORK  
BOARD
When the complete NETWORK board is exchanged, the MAC ad-
dress has been changed.
Please print and cut out the following explanations, and return it 
with the unit that completes the repair.
MAC address of this receiver has been changed by this repair. 
The customer who uses the MAC address fi ltering function of 
connected access point equipment please set it again. MAC ad-
dress is possible to confi rm it on the System Information screen 
of this unit. Please refer to “Adjusting Settings” on the operating 
instructions for details.
CONFIRMATION  OF  NETWORK  OPERATION
Note: When this confi rmation is executed, IP address is changed.
Necessary machinery and materials:
• 
PC (Windows XP/Vista)
• 
Router (Transmission rate is 100 Mbps or more, built-in DHCP 
server function)
• 
Two LAN cables
 
(Category 5 cable, normal type or shield type)
• Monitor
• 
Supplied remote commander (RM-AAU155) 
 
(US and Canadian models)
• 
Supplied remote control (RM-AAP082) (AEP model)
Connection:
(The router need not be connected with the internet)
LAN cable
router
PC
STR-
DA2800ES
monitor
NETWORK board
 
 jack (CN2502)
D-VIDEO board
HDMI OUT A ARC connector
(CN3502)
HDMI cable
Procedure:
1.  The setting of LAN of PC is setting to the automatic IP address 
assignment. 
 
It changes to the setting that displays the image in the monitor.
2.  Perform connection with reference to connection fi gure.
3.  The power supply of the router is turn on, next, the power sup-
ply of PC and this unit is turn on.
4.  Press the [HOME] button of the remote commander, the home 
menu is displayed in the monitor.
5.  The “Settings” is selected on the home menu, and press the [
button of remote commander.
6.  The “Network Settings” is selected , and press the [
] button 
of remote commander.
7.  The “Internet Settings” is selected , and press the [
] button of 
remote commander.
8.  The “Network Setup” is selected , and press the [
] button of 
remote commander.
9.  The “Auto” is selected , and press the [
] button of remote 
commander.
10. The “The network will be confi gured with the following set-
tings.” is displayed, and press the [
,
] button of remote com-
mander.
11.  The “Save & Connect” is selected , and press the [
] button of 
remote commander.
12. The automatically connect function is performed.
13. Confi rm that the “Internet Access:   OK” has been displayed,  
and press the [
] button of remote commander.
14. Press the [\/1] button to turn off the main power.
Ver. 1.2
STR-DA2800ES
7
Jig No.
Jig Name
Part No.
Pitch (mm)
Cores
Remark
1
1.25_22_M
J-2501-350-A
1.25
22
For CONTROL board (CN2515, 2701)
1.25_22_F
For MAIN board (CN302, 303)
Flexible fl at cable 22P
J-2501-364-A
Length 300 mm
2
1.25_26_F
J-2501-356-A
1.25
26
For CONTROL board (CN2891)
1.25_26_F
For D-AUDIO board (CN2231)
Flexible fl at cable 26P
J-2501-365-A
Length 300 mm
CONTROL  BOARD  SERVICE  POSITION
• 
Please connect following extension jig.
Connect extension jig 1
to the CONTROL board (CN2515) 
and MAIN board (CN302).
Connect extension jig 1
to the CONTROL board (CN2701) 
and MAIN board (CN303).
Connect extension jig 2
to the CONTROL board (CN2891) 
and D-AUDIO board (CN2231).
CONTROL board
(CN2515)
MAIN board
(CN303)
MAIN board
(CN302)
CONTROL board
(CN2891)
CONTROL board
(CN2701)
D-AUDIO board
(CN2231)
insulating sheet
alligator clip
Note: Connect altogether the metal part
 
on the boards connected with the
 
chassis using the alligator clip.
SUB  D-VIDEO  BOARD  SERVICE  POSITION
insulating sheet
SUB D-VIDEO board
alligator clip
Note: Connect altogether the metal part
on the boards connected with the
chassis using the alligator clip.
STR-DA2800ES
8
Jig No.
Jig Name
Part No.
Pitch (mm)
Cores
Remark
2
1.25_26_F
J-2501-356-A
1.25
26
For CONTROL board (CN2891)
1.25_26_F
For D-AUDIO board (CN2003)
Flexible fl at cable 26P
J-2501-365-A
Length 300 mm
3
2.00_19_M
J-2501-368-A
1.25
19
For MAIN board (CN301)
2.00_19_F
For D-AUDIO board (CN1114)
Flexible fl at cable 19P
J-2501-370-A
Length 400 mm
4
2.00_5_M
J-2501-369-A
1.25
5
For MAIN board (CN300)
2.00_5_F
For D-AUDIO board (CN2401)
Flexible fl at cable 5P
J-2501-371-A
Length 400 mm
D-AUDIO  BOARD  SERVICE  POSITION
• 
Please connect following extension jig.
OPT-COAX board
insulating sheet
Connect extension jig 2 
to the D-AUDIO board (CN2003) 
and CONTROL board (CN2891).
Connect extension jig 4 
to the D-AUDIO board (CN2401) 
and MAIN board (CN300).
Connect extension jig 3 
to the D-AUDIO board (CN1114) 
and MAIN board (CN301).
CONTROL board
(CN2891)
alligator clip
Note: Connect altogether the metal part
 
on the boards connected with the
 
chassis using the alligator clip.
D-AUDIO board
(CN2003)
D-AUDIO board
(CN1114)
D-AUDIO board
(CN2401)
MAIN board
(CN301)
MAIN board
(CN300)
Page of 127