DOWNLOAD Sony HBD-N5200W / HBD-N7200W / HBD-N7200WL / HBD-N9200W / HBD-N9200WL Service Manual ↓ Size: 13.7 MB | Pages: 127 in PDF or view online for FREE

Model
HBD-N5200W HBD-N7200W HBD-N7200WL HBD-N9200W HBD-N9200WL
Pages
127
Size
13.7 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
hbd-n5200w-hbd-n7200w-hbd-n7200wl-hbd-n9200w-hbd-n.pdf
Date

Sony HBD-N5200W / HBD-N7200W / HBD-N7200WL / HBD-N9200W / HBD-N9200WL Service Manual ▷ View online

HBD-N5200W/N7200W/N7200WL/N9200W/N9200WL
33
2-23.  HOW  TO  BEND  FFC
: Mountain fold
: Valley fold
wire (flat type) (11 core), length 45 mm (Ref. No. 55)
flexible flat cable (8 core), length 145 mm (Ref. No. 57)
wire (flat type) (26 core), length 160 mm (Ref. No. 54)
wire (flat type) (9 core), length 215 mm (Ref. No. 157)
wire (flat type) (5 core), length 275 mm (Ref. No. 105)
flexible flat cable (45 core), length 238 mm (Ref. No. 156)
109 mm
20 mm
TOUCH_F board
(CN2702)
NFC
(RC-S801/A5 (WW))
The lower side
is contact side. 
The lower side
is contact side. 
MB1305 board
(CN801)
The lower side
is contact side. 
optical device
KEM480AHA/C2RP1
(OP1)
The lower side
is contact side. 
15 mm
75 mm
58 mm
180 mm
MB1305 board
(CN960)
The lower side
is contact side. 
The lower side
is contact side. 
52 mm
80 mm
135 mm
optical device
KEM480AHA/C2RP1
(OP1)
120 mm
60 mm
45º
45º
45º
275 mm
MB1305 board
(CN970)
The lower side
is contact side. 
The lower side
is contact side. 
200 mm
65 mm
210 mm
45º
45º
optical device
KEM480AHA/C2RP1
(OP1)
145 mm
45 mm
70 mm
30 mm
40 mm
50 mm
FL+CHUKEI
 board
(CN2301)
The lower side
is contact side. 
TOUCH_F board
(CN2700)
The lower side
is contact side. 
TOUCH_F board
(CN2701)
The lower side
is contact side. 
TOUCH_S board
(CN2964)
The lower side
is contact side. 
16 mm
HBD-N5200W/N7200W/N7200WL/N9200W/N9200WL
34
: Mountain fold
: Valley fold
wire (flat type) (9 core), length 120 mm (Ref. No. 302)
wire (flat type) (5 core), length 120 mm (Ref. No. 302)
wire (flat type) (15 core), length 55 mm (Ref. No. 301)
wire (flat type) (28 core), length 320 mm (Ref. No. 255)
flexible flat cable (24 core), length 220 mm (Ref. No. 356)
flexible flat cable (26 core), length 335 mm (Ref. No. 357)
220 mm
260 mm
MB1305 board
(CN703)
The lower side
is contact side. 
AMP board
(CN3505)
The lower side
is contact side. 
MB1305 board
(CN701)
The upper side
is contact side. 
AUDIO IO board
(CN2000)
The upper side
is contact side. 
15 mm
15 mm
25 mm
MB1305 board
(CN1005)
FL+CHUKEI board
(CN2300)
The lower side
is contact side. 
The upper side
is contact side. 
60 mm
118 mm
shielded type
30 mm
68 mm
35 mm
MB1305 board
(CN1001)
The lower side
is contact side. 
LED CHUKEI board
(CN4000)
(N7200WL/N9200WL)
The lower side
is contact side.  17 mm
68 mm
35 mm
MB1305 board
(CN1001)
The lower side
is contact side. 
LED CHUKEI board
(CN4006)
(N5200W/N7200W/N9200W)
The lower side
is contact side.  17 mm
MB1305 board
(CN702)
The lower side
is contact side. 
RF MODULATOR
(WS001)
The lower side
is contact side. 
335 mm
HBD-N5200W/N7200W/N7200WL/N9200W/N9200WL
35
SECTION  3
TEST  MODE
Note:
TA-SA500WR : Surround amplifi er for HBD-N7200W/N9200W
TA-SA600WR : Surround amplifi er for HBD-N7200WL/N9200WL
TA-SA700WR : Surround amplifi er for HBD-N5200W
COLD  RESET (MAIN  UNIT)
The cold reset clears data except BD/DVD data stored in the RAM 
to initial conditions. Execute this mode when returning the unit to 
the customers.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Touch the [
x
] and [VOL –] sensors simultaneously and hold 
down (around 5 seconds).
3.  The message “WAIT” then “RESET” appears on fl uorescent 
indicator tube, then becomes standby states.
DEMO  MODE
This mode let you lock the disc tray. When this mode is activated, 
the disc will not eject when the [
Z
] button is pressed. The message 
“D. LOCK” will be displayed on the fluorescent indicator tube.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Set a disc.
3.  Press the [HOME] button on the remote commander to enter 
the home menu.
4.  Touch the [
x
] sensor, press the [
Z
] button simultaneously and 
hold down until “D. LOCK” or “D. ON” displayed on the fluo-
rescent indicator tube (around 5 seconds).
Releasing method:
Touch the [
x
] sensor, press the [
Z
] button simultaneously and 
hold down until “D. OFF” displayed on the fl uorescent indicator 
tube (around 5 seconds).
PANEL TEST
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press button in order of the [
x
 [DISPLAY] [m] [M]  
on the remote commander.
 
(Make the interval when each button is pressed within two sec-
onds).
3. All 
segments 
in 
fl uorescent indicator tube are lighted up. And 
half segments in fl uorescent indicator tube are lighted up, oth-
ers half segments in fl uorescent indicator tube are lighted up, 
then all segments in fl uorescent indicator tube are lighted up. 
This operation is repeated.
4.  In the state of step 3, touch the [VOL +] sensor and model 
name is displayed on the fl uorescent indicator tube.
 
Each time the [VOL +] sensor is touched, the display changes 
from destination information, STR version, IFCON Audio 
Coeffi cient Version, BDSYSCON Audio Coeffi cient Version, 
special mode in this order, and returns to the model name 
display.
5.  In the state of step 3, touch the [FUNCTION] sensor and “K 0” 
is displayed on the fluorescent indicator tube.
 
“K 0” value increases whenever a button is pressed or a sensor 
is touched. However, once a button is pressed or a sensor is 
touched, it is no longed taken into account.
 
All buttons is pressed and all sensors is touched, “OK” and “K 
9” are alternately displayed on the fluorescent indicator tube.
Releasing method:
Press the [
?/1
] button to turn the power off.
DISC  LID  LOCK  MODE
The EJECT operation by main unit, remote commander, and CEC 
(path-through) can be prohibited.
Procedure:
1.  Press the [\/1] button to turn the power on.
2.  Set a disc.
3.  Press button in order of the [
x
 [DISPLAY] [COLOR 
PATTERN] 
[M] on the remote commander.
 
(Make the interval when each button is pressed within two 
seconds).
4.  “TLK. ON” is displayed on the fl uorescent indicator tube, and 
the EJECT operation by main unit, remote commander, and 
CEC (path-through) is prohibited.
Releasing method:
1.  Press button in order of the [
x
 [DISPLAY] [COLOR 
PATTERN] 
[M] on the remote commander.
 
(Make the interval when each button is pressed within two 
seconds)
2.  “TLK.OFF” is displayed on the fl uorescent indicator tube, and 
the EJECT operation by main unit, remote commander, and 
CEC (path-through) become effective.
HBD-N5200W/N7200W/N7200WL/N9200W/N9200WL
36
7.  The message “Close” appears, and press the [
] button on the 
remote commander.
Initialize Personal Information
Close
Initialisation complete.
8.  Select “Reset to Factory Default Settings”, and press the [
button on the remote commander.
Initialize Personal Information
Reset to Factory Default Settings
Restore each setting to the factory
default setting.
9.  Select “All Settings”, and press the [
] button on the remote 
commander.
Reset to Factory Default Settings
Parental Control Settings
Music Settings
System Settings
External Input Settings
Network Settings
All Settings
10. Select “Start”, and press the [
] button on the remote com-
mander.
All Settings
Restore all settings to the factory default
settings. The system will turn off after
reset.
Start
Cancel
11. Initialization ends when the message “HELLO” on the 
fl uorescent indicator tube disappears.
FACTORY  INITIALIZE
Return all of the unit setting to their factory defaults.
Note 1: Disconnect the following connections when you use this mode.
 
   
 USB
 
   
 LAN
 
   
 HDMI IN 1
 
   
 HDMI IN 2
Note 2: The operation in this mode must use a remote commander and TV 
monitor.
Procedure:
1.  Connect this unit with TV monitor.
2.  Press the [
?/1
] button to turn the power on. 
3.  Press the [HOME] button on the remote commander, and the 
home menu is displayed.
4. Select 
“Setup” 
 “Resetting”, and press the [ ] button on the 
remote commander.
Resetting
Easy Network Settings
5.  Select “Initialize Personal Information”, and press the [
button on the remote commander.
Initialize Personal Information
Delete personal data when 
disposing of or transferring this
device.
Reset to Factory Default Settings
6.  Select “OK”, and press the [
] button on the remote com-
mander.
Initialize Personal Information
OK
Cancel
Deleting Personal Information.
Do you want to proceed?
If you destroy or transfer or resell this unit, 
please delete all Personal Information
for security reasons.
Please take appropriate measures such as
logging out after using a network service.
Ver. 1.1
Page of 127
Display

Click on the first or last page to see other HBD-N5200W / HBD-N7200W / HBD-N7200WL / HBD-N9200W / HBD-N9200WL service manuals if exist.