DOWNLOAD Sharp XV-Z21000 (serv.man11) Service Manual ↓ Size: 11.12 MB | Pages: 68 in PDF or view online for FREE

Model
XV-Z21000 (serv.man11)
Pages
68
Size
11.12 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Projector
File
xv-z21000-sm11.pdf
Date

Sharp XV-Z21000 (serv.man11) User Manual / Operation Manual ▷ View online

-47
Appendix
Info
• If the temperature warning indicator illuminates and the projector enters the standby mode, ensure the 
exhaust and intake vents are not blocked (page 
6) and then try turning the power back on. Wait until the 
projector has cooled down completely (at least 10 minutes) before plugging in the power cord and turning 
the power back on. 
• If the power is turned off for a brief moment due to power outage or some other cause while using the 
projector, and the power supply recovers immediately after that, the lamp indicator will illuminate in red 
and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace the power 
cord in the AC outlet and then turn the power on again.
• The speed and pitch of the cooling fan may change during operation in response to internal temperature 
changes. This is normal operation and does not indicate a malfunction.
• Do not unplug the power cord immediately after the projector has entered the standby mode or while the 
cooling fan is running. The cooling fan runs for about 90 seconds.
Cleaning the projector
■  Be sure to unplug the power cord before cleaning the 
projector.
■  The cabinet as well as the operation panel is made of 
plastic. Avoid using benzene or thinner, as these can 
damage the fi nish on the cabinet.
■  Do not use volatile agents such as insecticides on the 
projector.
 
Do not attach rubber or plastic items to the projector for 
long periods.
 
The effects of some of the agents in the plastic may 
cause damage to the quality or fi nish of the projector.
■  Wipe off dirt gently with a soft fl annel cloth.
■  When the dirt is hard to remove, soak a cloth in a mild 
detergent diluted with water, wring the cloth well and 
then wipe the projector.
 
Strong cleaning detergents may discolor, warp or dam-
age the coating on the projector. Make sure to test on a 
small, inconspicuous area on the projector before use.
Cleaning the lens
■  Use a commercially available blower or lens cleaning 
paper (for glasses and camera lenses) for cleaning the 
lens. Do not use any liquid type cleaning agents, as 
they may wear off the coating fi lm on the surface of the 
lens.
■  As the surface of the lens can easily get damaged, be 
sure not to scrape or hit the lens.
Cleaning the exhaust and intake vents
■  Use a vacuum cleaner to clean dust from the exhaust 
vent and the intake vent.
■  The exhaust and intake vents should be cleaned every 
100 hours of use. Clean the vents more often when the 
projector is used in a dirty or smoky location.
Info
• If you want to clean the exhaust and intake vents 
during projector operation, be sure to press 
STANDBY on the projector or 
STANDBY on 
the remote control and put the projector into 
standby mode. After the cooling fan has stopped, 
clean the vents.
Mild detergent
diluted with water
Wax
Mild deter
gent
Thinner
XVZ21000_E_Ousyu_P46-51.indd   47
XVZ21000_E_Ousyu_P46-51.indd   47
2006/07/31   19:55:52
2006/07/31   19:55:52
-48
Regarding the Lamp
Lamp
■  It is recommended that the lamp be replaced with a new one (sold separately) when the remaining 
lamp life becomes 5% or less, or when you notice a signifi cant deterioration in the picture and color 
quality. The lamp life (percentage) can be checked with the on-screen display. (See page 43.)
■  Purchase a replacement lamp of type AN-K20LP from your place of purchase, nearest Sharp Autho-
rized Service Center or Dealer.
Caution Concerning the Lamp
■  This projector utilizes a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp 
failure can be attributed to numerous sources such as: excessive shock, improper cooling, surface 
scratches or deterioration of the lamp due to a lapse of usage time.
  The period of time up to failure largely varies depending on the individual lamp and/or the condition 
and the frequency of use. It is important to note that failure can often result in the bulb cracking.
■  When the lamp replacement indicator and on-screen display icon are illuminated, it is recommended 
that the lamp be replaced with a new one immediately, even if the lamp appears to be operating 
normally.
■  Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the 
lamp may be vented into the room from the exhaust vent. Because the gas in this lamp includes mer-
cury, ventilate the room well if the lamp breaks and avoid all exposure to the released gas. In case of 
exposure to the gas, consult a doctor as soon as possible.
■  Should the lamp break, there is also a possibility that glass particles may spread inside of the projec-
tor. In such a case, it is recommended you contact your nearest Sharp Authorized Service Center or 
Dealer to assure safe operation.
Replacing the Lamp
Caution
• Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burn 
or injury.
• Wait at least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool 
before removing the lamp unit.
■  Carefully change the lamp by following the instructions described in this section. *If you wish, you 
may have the lamp replaced at your nearest Sharp Authorized Service Center or Dealer.
* If the new lamp does not light after replacement, take your projector to the nearest Sharp Authorized Service 
Center or Dealer for repair.
XVZ21000_E_Ousyu_P46-51.indd   48
XVZ21000_E_Ousyu_P46-51.indd   48
2006/07/31   19:55:53
2006/07/31   19:55:53
-49
Appendix
Info
• Be sure to remove the lamp unit by the han-
dle. Be sure not to touch the glass surface of 
the lamp unit or the inside of the projector.
• To avoid injury to yourself and damage to the 
lamp, be sure to carefully follow the steps 
below.
• Do not loosen other screws than for the lamp 
unit cover and lamp unit.
  (As for the lamp unit, only the silver screws 
are loosened.)
1
 Press  STANDBY on the pro-
jector or  STANDBY on the re-
mote control to put the projector 
into the standby mode.
• Wait until the cooling fan stops.
2
  Disconnect the power cord.
• Unplug the power cord from the AC 
socket.
• Leave the lamp until it has fully cooled 
down (about 1 hour).
3
  Remove the lamp unit cover.
• Loosen the user service screws that 
secure the lamp unit cover. Then open 
the cover in the direction of the arrow.
4
  Remove the lamp unit.
• Loosen the securing screws from the 
lamp unit. Hold the lamp unit by the 
handle and pull it in the direction of the 
arrow.
Removing and Installing the Lamp Unit
Warning!
 
• The lamp unit becomes very hot while the projector is operating. Do not remove the lamp 
unit from the projector right after use. The lamp and parts around the lamp will be very hot 
and may cause burns or injury.
Lamp unit
(Type: AN-K20LP)
Optional 
accessory
STANDBY button
STANDBY
User service screws
Lamp unit
Lamp unit cover
Securing screw
Securing screws
Handle
AC socket
XVZ21000_E_Ousyu_P46-51.indd   49
XVZ21000_E_Ousyu_P46-51.indd   49
2006/07/31   19:55:54
2006/07/31   19:55:54
-50
5
  Insert the new lamp unit.
• Press the lamp unit fi rmly into the lamp 
unit compartment. Fasten the securing 
screws.
6
  Attach the lamp unit cover.
• Close the lamp unit cover in the direc-
tion of the arrow. Then tighten the user 
service screws.
Info
• If the lamp unit and lamp unit cover are not 
correctly installed, the power will not turn on, 
even if the power cord is connected to the 
projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Info
• Make sure to reset the lamp timer only when 
replacing the lamp. If you reset the lamp timer 
and continue to use the same lamp, this 
may cause the lamp to become damaged 
or explode.
1
  Connect the power cord.
• Plug the power cord into the AC socket 
of the projector.
2
  Reset the lamp timer.
• While holding down  ENTER, " and 
| on the projector, press 
ON on the 
projector.
• “LAMP 0000H” is displayed, indicating 
that the lamp timer is reset.
1
2
ENTER button
ON button
Regarding the Lamp (Continued)
Securing screws
AC socket
User service screws
Adjustment button"
Adjustment button|
XVZ21000_E_Ousyu_P46-51.indd   50
XVZ21000_E_Ousyu_P46-51.indd   50
2006/07/31   19:55:55
2006/07/31   19:55:55
Page of 68
Display

Click on the first or last page to see other XV-Z21000 (serv.man11) service manuals if exist.