DOWNLOAD Sharp XV-Z100 (serv.man3) Service Manual ↓ Size: 5.09 MB | Pages: 65 in PDF or view online for FREE

Model
XV-Z100 (serv.man3)
Pages
65
Size
5.09 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Projector
File
xv-z100-sm3.pdf
Date

Sharp XV-Z100 (serv.man3) User Manual / Operation Manual ▷ View online

9
Intr
oduction
■ When turning off the projector, the cooling fan
runs to decrease the internal temperature for
a while. Unplug the power cord after the cool-
ing fan stops. The period the cooling fan runs
will vary, depending on the circumstances and
the internal temperature.
Caution regarding usage of the projector
■ When using the projector, be sure not to sub-
ject it to hard impact and/or vibration, as this
can result in damage. Take extra care with
the lens. Before moving the projector, be sure
to unplug the power cord from the wall outlet,
and disconnect any other cables connected
to it.
■ Do not carry the projector by holding the lens.
■ When storing the projector, re-attach the lens
cap. (See page 11).
■ Do not expose the projector to direct sunlight
or place next to heat sources. Doing so may
affect the cabinet color or cause deformation
of the plastic cover.
Other connected equipment
■ When connecting a computer or other audio-
visual equipment to the projector, make the
connections AFTER unplugging the power
cord of the projector from the AC outlet and
turning off the equipment to be connected.
■ Please read the operation manuals of the pro-
jector and the equipment to be connected for
instructions on how to make the connections.
Info
• The cooling fan regulates the internal tem-
perature, and its performance is automatically
controlled. The sound of the fan may change
during projector operation due to changes in
the fan speed. This does not indicate malfunc-
tion.
• Do not unplug the power cord during projec-
tion or cooling fan operation. This can cause
damage due to rise in internal temperature,
as the cooling fan also stops.
Using the projector in other countries
■ The power supply voltage and the shape of
the plug may vary depending on the region
or country you are using the projector in.
When using the projector overseas, be sure
to use an appropriate power cord for the coun-
try you are in.
Temperature monitor function
■ If the projector starts to overheat due to setup
problems or blockage of the air vents, “
” and
” will illuminate in the lower left corner
of the picture. If the temperature continues to
rise, the lamp will turn off, the temperature warn-
ing indicator on the projector will blink, and after
a 90-second cooling-off period the projector will
enter standby mode. Refer to “Maintenance In-
dicators” on page 48 for details.
XV-Z100_EN_b
05.8.25, 5:50 AM
9
10
Accessories
Remote control
RRMCGA430WJSA
Two R-6 batteries
 (“AA” size, UM/SUM-3,
HP-7 or similar)
3 RCA to 15-pin
D-sub adaptor
(11.8" (30 cm))
QCNWGA075WJPZ
• Operation manual
Optional accessories
■ Lamp unit
■ DIN-D-sub RS-232C adaptor (5 
57
/
64
o (15 cm))
AN-100LP
AN-A1RS
Supplied accessories
21 pin RCA
conversion adaptor
QSOCZ0361CEZZ
• Some of the optional accessories may not be available depending on the region. Please check with
your nearest Sharp Authorized Projector Dealer or Service Center.
Note
Lens cap (attached)
CCAPHA024WJSA
Video cable
QCNWGA001WJZZ
Power cord*
For Europe,
except U.K.
(6' (1.8 m))
QACCVA011WJPZ
For U.K. and
Singapore
(6' (1.8 m))
QACCBA036WJPZ
For Australia, New
Zealand and Oceania
(6' (1.8 m))
QACCLA018WJPZ
(1)
(2)
(3)
* Use the power cord that corresponds to the wall outlet in your country.
XV-Z100_EN_c
05.8.29, 7:07 AM
10
Intr
oduction
11
33
39
48
32
30
30
31
47
30
15
28
28, 48
39, 46
28, 48
39
Top View
STANDBY/ON
button
For turning the
power on and
putting the
projector into
standby mode.
Lamp indicator
Temperature warning
indicator
Adjustment buttons
(P/R/O/Q)
For selecting menu items.
Volume buttons
(–O/Q+)
For adjusting the speaker
sound level.
ENTER button
For setting
items selected
or adjusted on
the menu.
MENU/HELP button
For displaying
adjustment and
setting screens, and
help screen.
Front View
Focus ring
For adjusting
the focus.
INPUT buttons (P/R)
For switching input mode
1, 2, 3 or 4.
Remote control
sensor
HEIGHT
ADJUST
lever
Numbers in Z refer to the main pages in this operation manual where the topic
is explained.
Part Names and Functions
Projector
KEYSTONE
button
For entering
the Keystone
Correction
mode.
Intake vent
Power
indicator
Zoom ring
For enlarging/
reducing the picture.
Push both sides of the lens cap
to attach or remove.
XV-Z100_EN_c
05.8.25, 5:51 AM
11
12
Numbers in Z refer to the main pages in this operation manual where the topic
is explained.
Rear View
Part Names and Functions (Continued)
Speaker
Rear adjustment
foot
Kensington Security
Standard connector
AC socket
Connect the
supplied Power cord.
Intake vent
Exhaust vent
47
31
45
47
28
1
2
6
7
8
3
4
5
Terminals
Using the Kensington Lock
• This projector has a
Kensington Security Standard
connector for use with a
Kensington MicroSaver
Security System. Refer to the
information that came with the
system for instructions on how
to use it to secure the
projector.
Terminal
Description
Page
INPUT 1, 2 terminal
■ Connecting video equipment with component output terminal
(DVD player, DTV decoder, DVD recorder with hard disc, etc.).
23
1
■ Connecting the computer.
2
25
AUDIO (INPUT 1, 2) terminal
Connecting an audio cable (Shared audio input terminal for INPUT 1 and 2).
25
OUTPUT (INPUT 1, 2) terminal
Connecting the monitor when you want to simultaneously watch the
projection image on the monitor. (Shared computer RGB and
component signals output terminal for INPUT 1 and 2).
3
26
INPUT 3 terminal
Connecting video equipment with S-video output terminal (VCR, DVD
player, etc.).
4
23
24
RS-232C terminal
Connecting the computer to control the projector.
5
AUDIO OUTPUT terminal
Connecting to an amplifier or other audio equipment with an audio cable
(commercially available) (Shared audio output terminal for INPUT 1, 2, 3 and 4).
6
27
INPUT 4 terminal
Connecting video equipment without S-video output terminal.
24
AUDIO (INPUT 3, 4) terminal
Connecting an audio cable (Shared audio input terminal for INPUT 3 and 4).
7
24
8
26
XV-Z100_EN_c
05.8.25, 5:51 AM
12
Page of 65
Display